Search NASASearch

Engineering topics

Wilbur, P. J.

Publications and source records attributed to Wilbur, P. J..

At least 19 records

Physical and Tribological Characteristics of Ion-Implanted Diamond Films

Unidirectional sliding friction experiments were conducted with a natural, polished diamond pin in contact with both as-deposited and carbon-ion-implanted diamond films in ultrahigh vacuum. Diamond films were deposited on silicon, silicon carbide, and silicon nitride by microwave-plasma-assisted chemical vapor deposition. The as-deposited diamond films were impacted with carbon ions at an accelerating energy of 60 keV and a current density of 50 micron A/cm(exp 2) for approximately 6 min, resulting in a dose of 1.2 x 10(exp 17) carbon ions/cm(exp 2). The results indicate that the carbon ion implantation produced a thin surface layer of amorphous, nondiamond carbon. The nondiamond carbon greatly decreased both friction and wear of the diamond films. The coefficients of friction for the carbon-ion-implanted, fine-grain diamond films were less than 0.1, factors of 20 to 30 lower than those for the as-deposited, fine-grain diamond films. The coefficients of friction for the carbon-ion-implanted, coarse-grain diamond films were approximately 0.35, a factor of five lower than those for the as-deposited, coarse-grain diamond films. The wear rates for the carbon-ion-implanted, diamond films were on the order of 10(exp -6) mm(exp 3)/Nm, factors of 30 to 80 lower than that for the as-deposited diamond films, regardless of grain size. The friction of the carbon-ion-implanted diamond films was greatly reduced because the amorphous, nondiamond carbon, which had a low shear strength, was restricted to the surface layers (less than 0.1 micron thick) and because the underlying diamond materials retained their high hardness. In conclusion, the carbon-ion-implanted, fine-grain diamond films can be used effectively as wear resistant, self-lubricating coatings for ceramics, such as silicon nitride and silicon carbide, in ultrahigh vacuum.

Miyoshi, K.

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance is described. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Results show that the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid and that the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline. Moreover, the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.

Vaughn, J. A.

Space-charge-limited current flow in a spherical double sheath

The solutions presently obtained for counterflowing, space charge-limited negatively and positively charged particle currents between two spherical surfaces indicate that the current magnitudes exhibit the usual 3/2-power dependence on driving potential difference and square root dependence on particle charge/mass ratio. The magnitude of either current strongly depends on the radius ratio of the two spherical surfaces, while the relative magnitudes of the two counterflowing currents are related by the square root of the mass ratio of the two charged particle species and a radius ratio factor that lies in the 0.1-1.0 range.

Wei, R.

Advanced electric propulsion and space plasma contactor research

A series of experiments performed on an 8 cm dia. ring cusp magnetic field ion thruster are described. The results show the effects of anode and cathode position and size, ring cusp axial location and discharge chamber length on plasma ion energy cost and extracted ion fraction. Thruster performance is shown to be improved substantially when optimum values of these parameters are used. Investigations into the basic plasma phenomena associated with the process of plasma contacting are described. The results show the process of electron collection from a background plasma to a hollow cathode plasma contactor exhibits a higher impedance than the process of electron emission from the hollow cathode. The importance of having cold ions present to facilitate the plasma contacting process is shown. Results of experiments into the behavior of hollow cathodes operating at high interelectrode pressures (up to approx. 100 Torr) on nitrogen and ammonia are presented. They suggest that diffuse emission from the insert of a hollow cathode can be sustained at high interelectrode pressures if the cathode is made of non-conducting material and the cathode internal pressure is reduced by evacuating the cathode interior. A theoretical model of discharge chamber operation developed for inert gas thrusters is extended so it can be used to evaluste the performance of mercury ion thrusters. Predictions of the model are compared to experimental results obtained on two 30 cm dia. thrusters.

Wilbur, P. J.

Calculation of plasma properties in ion sources

Simple algebraic equations are developed that can be used to calculate the average primary electron density, the average primary to Maxwellian density ratio, and the average Maxwellian electron temperature in the discharge chamber of a cusped magnetic field ion source. These properties may be calculated as functions of the propellant gas flow rate and the propellant utilization efficiency. Each of the plasma properties calculated using the model agrees well with the corresponding experimental data for both argon and xenon gases over a wide range of propellant flow rates and utilization efficiencies.

Brophy, J. R.

Ring cusp discharge chamber performance optimization

An experimental study of the effects of discharge chamber length and the locations of the anode, cathode and ring cusp within the chamber on the performance of an 8 cm dia. ring cusp thruster is described. As these lengths and positions are varied the changes induced in plasma ion energy costs, extracted ion fractions and ion beam profiles are measured. Results show that the anode may be positioned at any location along an 'optimum virtual anode' magnetic field line and minimum plasma ion energy costs will result. The actual location of this field line is related to a 'virtual cathode' magnetic field line that is defined by the cathode position. The magnetic field has to be such that the virtual anode field line intersects the grids at the outermost ring of grid holes to maximize the extracted ion fraction and flatten the ion beam profile. Discharge chamber lengths that were as small as possible in the test apparatus yielded the lowest extracted ion fractions.

Hiatt, J. M.

Advanced ion thruster research

A series of experiments conducted on a ring cusp magnetic field ion thruster; in which the anode, cathode and discharge chamber backplate were moved relative to the magnetic cusp; are described. Optimum locations for the anode, cathode and backplate which yield the lowest energy cost per plasma ion and highest extracted ion fraction are identified. The results are discussed in terms of simple physical models. The results of preliminary experiments into the operation of hollow cathodes on nitrogen and xenon over a large pressure range (0.1 to 100 Torr) are presented. They show that the cathode discharge transfers from the cathode insert to the exterior edge of the orifice plate as the interelectrode pressure is increased. Experimental evidence showing that a new ion extractor grid concept can be used to stabilize the plasma sheath at the screen grid is presented. This concept, identified by the term constrained sheath optics, is shown to hold ion beamlet divergence and impingement characteristics to stable values as the beamlet current and the net and total accelerating voltages are changed. The current status of a study of beamlet vectoring induced by displacing the accelerator and/or decelerator grids of a three grid ion extraction system relative to the screen grid is discussed.

Wilbur, P. J.

Ion extraction capabilities of two-grid accelerator systems

An experimental investigation into the ion extraction capabilities of two-grid accelerator systems common to electrostatic ion thrusters is described. This work resulted in a large body of experimental data which facilitates the selection of the accelerator system geometries and operating parameters necessary to maximize the extracted ion current. Results suggest that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 0.5 mm. Impingement-limited performance is shown to depend most strongly on grid separation distance, accelerator hole diameter ratio, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained at small grid separation ratios suggest a new grid operating condition where high beam current per hole levels are achieved at a specified net accelerating voltage. It is shown that this operating condition is realized at an optimum ratio of net-to-total accelerating voltage ratio which is typically quite high. The apparatus developed for this study is also shown to be well suited measuring the electron backstreaming and electrical breakdown characteristics of two-grid accelerator systems.

Rovang, D. C.

Advanced ion thruster research

A simple model describing the discharge chamber performance of high strength, cusped magnetic field ion thrusters is developed. The model is formulated in terms of the energy cost of producing ions in the discharge chamber and the fraction of ions produced in the discharge chamber that are extracted to form the ion beam. The accuracy of the model is verified experimentally in a series of tests wherein the discharge voltage, propellant, grid transparency to neutral atoms, beam diameter and discharge chamber wall temperature are varied. The model is exercised to demonstrate what variations in performance might be expected by varying discharge chamber parameters. The results of a study of xenon and argon orificed hollow cathodes are reported. These results suggest that a hollow cathode model developed from research conducted on mercury cathodes can also be applied to xenon and argon. Primary electron mean free paths observed in argon and xenon cathodes that are larger than those found in mercury cathodes are identified as a cause of performance differences between mercury and inert gas cathodes. Data required as inputs to the inert gas cathode model are presented so it can be used as an aid in cathode design.

Wilbur, P. J.

The effect of discharge chamber wall temperature on ion thruster performance

Experiments conducted on a ring cusp ion thruster that could be maintained at temperatures in the range 80 K to 500 K during operation by cooling it with liquid nitrogen are described. The measured changes in performance induced by discharge chamber wall temperature changes are compared to those predicted by a simple discharge chamber model. Good agreement between the temperature induced effects predicted by the model and measured results are demonstrated. Decreases in wall temperature to about 90 K are shown to effect substantial improvements in performance.

Wilbur, P. J.

Simple performance model for ring and line cusp ion thrusters

A model is developed for high magnetic field strength cusped thrusters which results in a single equation describing the thruster performance. Such a simple result is made possible by formulating the model in terms of the average energy expended in producing ions in the discharge plasma and the fraction of these ions that are extracted into the beam. A key feature of the model is that it allows one to calculate the average plasma ion energy cost as a function of the propellant utilization knowing only thruster geometric design parameters and the propellant gas. The model is exercised to indicate the effects on performance resulting from changes in the extracted ion fraction, the quality of the containment of primary electrons, the propellant mass flow rate, the propellant gas and the transparency of the accelerator system to neutral atoms.

Brophy, J. R.