Search NASA⌕ Search

Engineering topics

Wilcox, Fred A

Publications and source records attributed to Wilcox, Fred A.

Use of Subsonic Diffuser Mach Number as a Supersonic-Inlet Control Parameter

A Mach number measured in the subsonic diffuser was used experimentally as the inlet control parameter of a bypass control system for an axisymmetric supersonic inlet operated in combination with a J34 turbo-jet engine at Mach numbers from 1.6 to 2.0. The control maintained the inlet in either critical or supercritical operation, and, when set for critical diffuser operation, the control recovered from disturbances that placed the inlet in both subcritical buzz and supercritical operation. A slotted-rake orifice gave a more representative value of subsonic diffuser Mach number than the single total-pressure probe used as a control input.

Whalen, Paul P↗

Thrust and drag characteristics of a convergent-divergent nozzle with various exhaust jet temperatures

An investigation was conducted in the 8-by-6 foot supersonic wind tunnel on the effect of exhaust-gas temperatures on the external and internal characteristics of a convergent-divergent nozzle having an area expansion ratio of 1.83. Data were obtained over a pressure-ratio range from 1 to 20 at free-stream Mach numbers of 1.6 and 2.0 for exhaust temperatures of 860 degrees, 1650 degrees, and 2000 degrees R. Results of this investigation indicated that generally both the internal and external performance characteristics were only slightly affected by a large change in jet temperature. The small differences in performance which did occur were predicted satisfactorily from theoretical considerations.

Hearth, Donald P↗