Search NASA⌕ Search

Engineering topics

Wilde, Carl Huerstel

Publications and source records attributed to Wilde, Carl Huerstel.

At least 19 records

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

47 OTHER INSTRUMENTATION↗

Source localization for neutron imaging systems using convolutional neural networks

The nuclear imaging system at the National Ignition Facility (NIF) is a crucial diagnostic for determining the geometry of inertial confinement fusion implosions. The geometry is reconstructed from a neutron aperture image via a set of reconstruction algorithms using an iterative Bayesian inference approach. An important step in these reconstruction algorithms is finding the fusion source location within the camera field-of-view. Currently, source localization is achieved via an iterative optimization algorithm. In this paper, we introduce a machine learning approach for source localization. Specifically, we train a convolutional neural network to predict source locations given a neutron aperture image. We show that this approach decreases computation time by several orders of magnitude compared to the current optimization-based source localization while achieving similar accuracy on both synthetic data and a collection of recent NIF deuterium–tritium shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe 24A: Post shot Data and Analysis

The Multi-Probe 24A experiments took place on the Omega EP laser in November 2023. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron ion beams from a range of film thicknesses, and x-ray sources from the established CPC+Ta wire targets. The backlighter was used for ion acceleration in the pitcher series, in which deuteron and proton beams characterized as a function of CD film thickness to develop a pitcher for a pitcher-catcher neutron radiographic source, while also characterizing electrons and x-rays emitted perpendicular to the target (i.e. Crosstalk for sidelighter-driven x-ray beams). The sidelighter was used for electron acceleration in the x-ray series, in which the electron acceleration and subsequent x-rays was characterized from the CPC+Ta wire targets and radiography was conducted with and without electro-magnetic electron defection. For the pitcher series, we found that at 500 J and 0.7 ps the 700-800 nm CD films yielded the greatest number and highest energy for both protons and deuterons. For the x-ray series, results demonstrated: a significant number of <100 keV x-rays are produced within the glue that fills the CPC cone, on-axis electron signal from the x-ray targets produce electrons resolvable up to ~10 MeV, and electron deflection (using MIFEDS) has a notable effect radiograph on noise reduction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First large capsule implosions in a frustum-shaped hohlraum

Here, we report on the first indirect-drive implosions driven by a dual conical frustum-shaped hohlraum denoted “frustraum” and the experimental tuning campaigns leading up to two layered implosions. The campaign used 1.2 and 1.4 mm inner radius high density carbon (HDC) capsules and represented the largest HDC capsules to be imploded on the National Ignition Facility via indirect drive. Several techniques were successfully implemented to control the Legendre mode 2 capsule symmetry of the implosions, including changing the wall angle of the frustraum, which is not possible with cylindrical hohlraums. A mode 4 feature was observed and its implications for hotspot mix discussed. Two layered implosions were conducted with 1.2 mm inner radius capsules, the latter of which achieved the highest layered capsule absorbed energy on the National Ignition Facility using only 1.74 MJ of laser energy. The layered implosion results, along with generalized Lawson parameters, suggest that increasing the energy absorbed by the capsule at the expense of long coast times makes it more challenging to achieve ignition and that further reducing coast time (time between end of laser pulse and bang time) closer to the 1 ns level is warranted to improve the areal density and make it easier to achieve the hotspot temperature, alpha heating, and yield amplification required for ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]

The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe 23A: Post shot Data and Analysis

The Multi-Probe 23A experiments took place on the Omega EP laser in December 2022. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The backlighter was used in the pitcher series, in which deuteron beams were generated to develop a pitcher for a pitcher-catcher neutron radiographic source. The sidelighter was used in the shielding series, in which proton beams was generated, and a metal shield, XBLK, was used to mitigate crosstalk between the proton target and image plates located perpendicularly to the proton beam axis. For the pitcher series, we found that we were able to generate a deuteron beam with CD film, but not CD foam, targets. For the shielding series, we found that 6 mm Al vastly outperformed similar thicknesses of Cu and Ta at mitigating the crosstalk, suggesting that electrons, rather than x-rays, are the primary source of crosstalk.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

Fast Neutron Imaging and Tomography at NIF [Slides]

The presentation at the first Prompt Radiation Detection and Imaging Workshop covered fast neutron and tomography work at the National Ignition Facility (NIF).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

Gamma Imaging on NIS3

Explore the source record for details and available documents.

Geppert-Kleinrath, Verena↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗