Search NASA⌕ Search

Engineering topics

Wilhelm, Andrew S.

Publications and source records attributed to Wilhelm, Andrew S..

Evaluation of light collection from highly scattering media using wavelength-shifting fibers

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the interaction event topology can be recorded with greater fidelity than in traditional highly transparent media with sensors at large distances from the light production region. Opaque scintillator detectors rely on wavelength-shifting fibers to extract the scintillation light; however, the efficiency of light collection has not yet been directly measured in experiment. We measured the efficiency of light collection as a function of the optical parameters of an opaque liquid and the distance from the origin of the light to the fiber. We use the experimental data to validate a Monte Carlo model of light transport and collection and discuss a simple diffusion model that reproduces the results of Monte Carlo simulation with high fidelity. Furthermore, this combination of validated models has the potential for use in predictions of performance in various designs of future opaque scintillator detectors such as LiquidO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Setup and Characterization of a 137 CS Dosimetry Calibration Source in a Space-constrained Environment

Proper characterization of 137 Cs sources used for dosimeter calibration and performance testing is crucial for accurate and precise knowledge of air kerma rate and delivered dose. A 269 GBq 137 Cs source was relocated to a new facility, which had a footprint of approximately 2.8 m × 3.6 m and a 3.4 m high ceiling. A small room size, such as in the new facility, may significantly increase backscatter from the walls or room return. Due to the limited source strength, a relatively close irradiation position of 1.00 m from the source was selected to decrease required exposure times. Proximity to the small but cylindrical source has the potential to alter the 1/r 2 relationship (inverse square law) of air kerma rate with distance associated with point sources. Practical tutorials concerning dosimetry irradiation facilities are largely absent from the archival literature. For those reasons, standard characterization experiments were repeated multiple times, great care was taken with positioning, several experiments were added to the standard ones, an ion chamber and dosimeters were used rather than film for greater accuracy and precision, and practical details of the process were recorded. The impacts of room size and finite source dimensions were quantified and mitigated by the efforts reported here. Finally, recommendations for simple but thorough facility characterization, beam calibration, and quality control resulted.

42 ENGINEERING↗