Search NASA⌕ Search

Engineering topics

Wilkerson, J. F.

Publications and source records attributed to Wilkerson, J. F..

Assay-based background projection for the Majorana Demonstrator using Monte Carlo uncertainty propagation

The background index (BI) is an important quantity to project and calculate the half-life sensitivity of neutrinoless double-𝛽 decay (0⁢𝜈⁢𝛽⁢𝛽) experiments. An analysis framework is presented to calculate the BI using the specific activities, masses, and simulated efficiencies of an experiments components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a BI distribution from the specific activity, mass, and efficiency distributions. This method is applied to the M AJORANA D EMONSTRATOR , which deployed arrays of high-purity Ge detectors enriched in 76 Ge to search for 0⁢𝜈⁢𝛽⁢𝛽. The original assay-based projection is requantified in the new framework, using the as-built geometry of the Demonstrator and additional assay information. While 47% higher than the original projection, the resulting BI of [8.95±0.36]×10 −4 cts/(keVkgyr) from the 232 Th and 238 U decay chains does not account for the higher-than-expected BI observed by the D EMONSTRATOR . Finally, this method enables us to demonstrate the statistical incompatibility between the D EMONSTRATOR 's observed background and the assay results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for charge non-conservation and Pauli exclusion principle violation with the M AJORANA D EMONSTRATOR

Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the M AJORANA D EMONSTRATOR experiment. Using a 37.5 kg yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the e → v e $\overline{v_e}$ v e decay channel by more than an order of magnitude. Here, we also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on the Decay of 180⁢𝑚 Ta

180m Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the Majorana Demonstrator, an experimental search for the neutrinoless double-beta decay of 76 Ge using an array of high-purity germanium detectors, to search for the decay of 180m Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background Majorana Demonstrator detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the 180m Ta half-life on the different decay channels. With new limits up to 1.5 × 10 19 years, we improved existing limits by one to two orders of magnitude. Furthermore, this result is the most sensitive search for a single β and electron capture decay ever achieved.

150 ≤ A ≤ 189↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗