Search NASA⌕ Search

Engineering topics

Wilkerson, Marianne Perry

Publications and source records attributed to Wilkerson, Marianne Perry.

Overview of Algorithms for Using Particle Morphology in Pre-Detonation Nuclear Forensics

A major goal in pre-detonation nuclear forensics is to infer the processing conditions and/or facility type that produced radiological material. This review paper focuses on analyses of particle size, shape, texture (“morphology”) signatures that could provide information on the provenance of interdicted materials. For example, uranium ore concentrates (UOC or yellowcake) include ammonium diuranate (ADU), ammonium uranyl carbonate (AUC), sodium diuranate (SDU), magnesium diuranate (MDU), and others, each prepared using different salts to precipitate U from solution. Once precipitated, UOCs are often dried and calcined to remove adsorbed water. The products can be allowed to react further, forming uranium oxides UO3, U3O8, or UO2 powders, whose surface morphology can be indicative of precipitation and/or calcination conditions used in their production. This review paper describes statistical issues and approaches in using quantitative analyses of measurements such as particle size and shape to infer production conditions. Statistical topics include multivariate t tests (Hotelling’s T 2 ), design of experiments, and several machine learning (ML) options including decision trees, learning vector quantization neural networks, mixture discriminant analysis, and approximate Bayesian computation (ABC). ABC is emphasized as an attractive option to include the effects of model uncertainty in the selected and fitted forward model used for inferring processing conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Review of Nuclear Forensics: 2016-2020

The study of nuclear forensics harkens back to the Manhattan Project-era, when scientists first started to analyze the debris from the 1945 Trinity test. Political turmoil stemming from the Cold War and the rehabilitation of Germany following WWII has led to new challenges in international security involving nuclear proliferation. Nuclear materials have, on occasion, been lost, misplaced, or stolen from former Soviet countries, and illicit materials have been interdicted all over the world. The National Technical Nuclear Forensics Center (NTNFC) was established in 2006, and has been at the forefront of drive to advance nuclear forensic capabilities in the United States. The ultimate goal of nuclear forensics is to examine nuclear and other radioactive materials using analytical techniques to determine origin and history of the material, particularly in the context of law enforcement investigations. Nuclear forensics can be divided into two parts: predetonation and post-detonation. Pre-detonation forensics, as the name implies, is the investigation of a nuclear material or weapon that has not been detonated or involved in an explosion, whereas postdetonation forensics is the study of activation or fission products in debris or the environment following the use of a nuclear or radiological dispersal device (RDD). Both parts require a number of analytical chemical and radiochemical techniques to determine identification of the material. Many advancements in analytical techniques, including rapidity, sample size, and forensic signatures have been made in recent years. The analytical methods that can be used in a nuclear forensic investigation, such as mass spectrometry and gamma spectroscopy, have been described in detail in previous reviews, including Straub et.al, and will not be explained here. This review will discuss recent publications (from 2016 to present) describing advancements of techniques such as radiochronometry, morphology, development of novel reference materials, and inter-laboratory collaborations for both pre- and post-detonation nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NOx speciation from copper dissolution in nitric acid/water solutions using FTIR spectroscopy

The speciation of NO 2 , NO, and N 2 O gases formed from the dissolution of copper in nitric acid is measured and characterized using Fourier-transform infrared (FTIR) spectroscopy. This study describes analysis of the gas phase species formed and ingrowths of their concentrations as a function of time. Acid concentrations range from 14 to 4 M and the NO 2 , NO, and N 2 O are analyzed using FTIR between 1585 and 2209 wavenumbers. The concentrations of the gases range from 0 to 230 ppm and change over time and as a function of acid concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of nitrogen-containing species produced from nitric acid/water systems

The speciation of gases formed in the vapor phase above HNO 3 -H 2 O mixtures at room temperature is measured and characterized using Fourier-transform infrared (FTIR) spectroscopy. Although studies of speciation of compounds have been performed in the solution phase, in this study we focus solely on the gas phase species formed over HNO 3 -H 2 O mixtures and their concentrations as a function of time. The nitric acid concentration in the experiments range from 14 to 4 M. The NO 2 , NO, and N 2 O (collectively known at NOx) gases are measured by FTIR at 1585, 1850, and 2208 wavenumbers, respectively. The concentrations of these NOx species ranges from 0 to 3 ppm and change over time as a function of acid concentration. Two purities of commercially available HNO 3 are used to prepare the HNO 3 -H 2 O mixtures. An analysis of thermodynamic data shows that the formation of NOx gases without the presence of a catalyst are thermodynamically favorable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗