Search NASA⌕ Search

Engineering topics

Wilkes, Robert L.

Publications and source records attributed to Wilkes, Robert L..

Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

Kennedy, Robert S.↗

A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

Kennedy, Robert S.↗

Development of a menu of performance tests self-administered on a portable microcomputer

Eighteen cognitive, motor, and information processing performance subtests were screened for self-administration over 10 trials by 16 subjects. When altered presentation forms of the same test were collectively considered, the battery composition was reduced to 10 distinctly different measures. A fully automated microbased testing system was employed in presenting the battery of subtests. Successful self-administration of the battery provided for the field testing of the automated system and facilitated convenient data collection. Total test administration time was 47.2 minutes for each session. Results indicated that nine of the tests stabilized, but for a short battery of tests only five are recommended for use in repeated-measures research. The five recommended tests include: the Tapping series, Number Comparison, Short-term Memory, Grammatical Reasoning, and 4-Choice Reaction Time. These tests can be expected to reveal three factors: (1) cognition, (2) processing quickness, and (3) motor. All the tests stabilized in 24 minutes, or approximately two 12-minute sessions.

Wilkes, Robert L.↗

Preliminary evaluation of a micro-based repeated measures testing system

A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

Kennedy, Robert S.↗