Publications and source records attributed to Wilkins, S C.

New In-pile Instrumentation to Support Fuel Cycle Research and Development

New and enhanced nuclear fuels are a key enabler for new and improved reactor technologies. For example, the goals of the next generation nuclear plant (NGNP) will not be met without irradiations successfully demonstrating the safety and reliability of new fuels. Likewise, fuel reliability has become paramount in ensuring the competitiveness of nuclear power plants. Recently, the Office of Nuclear Energy in the Department of Energy (DOE-NE) launched a new direction in fuel research and development that emphasizes an approach relying on first principle models to develop optimized fuel designs that offer significant improvements over current fuels. To facilitate this approach, high fidelity, real-time, data are essential for characterizing the performance of new fuels during irradiation testing. A three-year strategic research program is proposed for developing the required test vehicles with sensors of unprecedented accuracy and resolution for obtaining the data needed to characterize three-dimensional changes in fuel microstructure during irradiation testing. When implemented, this strategy will yield test capsule designs that are instrumented with new sensor technologies for the Advanced Test Reactor (ATR) and other irradiation locations for the Fuel Cycle Research and Development (FC R&D) program. Prior laboratory testing, and as needed, irradiation testing, of these sensors will have been completed to give sufficient confidence that the irradiation tests will yield the required data. Obtaining these sensors must draw upon the expertise of a wide-range of organizations not currently supporting nuclear fuels research. This document defines this strategic program and provides the necessary background information related to fuel irradiation testing, desired parameters for detection, and an overview of currently available in-pile instrumentation. In addition, candidate sensor technologies are identified in this document, and a list of proposed criteria for ranking these technologies. A preliminary ranking of candidate technologies is performed to illustrate the path forward for developing real-time instrumentation that could provide the required data for the FC R&D program. This draft document is a starting point for discussion with instrumentation experts and organizations. It is anticipated that the document will be used to stimulate discussions on a wide-range of sensor technologies and to gain consensus with respect to the path forward for accomplishing the goals of this research program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extension Wire for High Temperature Irradiation Resistant Thermocouples

In an effort to reduce production costs for the doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs) recently developed by the Idaho National Laboratory (INL), a series of evaluations were completed to identify an optimum compensating extension cable. Results indicate that of those combinations tested, two inexpensive, commercially-available copper nickel alloy wires approximate the low temperature (0 to 500oC) thermoelectric output of KW-Mo versus Nb-1%Zr in HTIR-TCs. For lower temperatures (0 to 150oC), which is the region where soft extension cable is most often used, results indicate that the thermocouple emf is best replicated by the Cu-3.5%Ni versus Cu-5%Ni combination (measured emfs were within 4% at 100 and 150oC). At higher temperatures (300 to 500oC), data suggest that the Cu-5%Ni versus Cu-10%Ni combination may yield data closer to that obtained with KW-Mo versus Nb-1%Zr wires (measured emfs were within 8%). Further, interpolation of test results suggest that a combination containing a negative thermoelement with slightly lower nickel content, such as Cu-5%Ni versus Cu-9%Ni, may yield more representative data if extension cable is needed for these higher temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long Duration Testing of Type C Thermocouples at 1500 °C

Experience with Type C thermocouples operating for long periods in the 1400 to 1600 °C temperature range indicate that significant decalibration occurs, often leading to expensive downtime and material waste. As part of an effort to understand the mechanisms causing drift in these thermocouples, the Idaho National Laboratory conducted a long duration test at 1500 °C containing eight Type C thermocouples. As report in this document, results from this long duration test were adversely affected due to oxygen ingress. Nevertheless, results provide key insights about the impact of precipitate formation on thermoelectric response. Post-test examinations indicate that thermocouple signal was not adversely impacted by the precipitates detected after 1,000 hours of heating at 1,500 °C and suggest that the signal would not have been adversely impacted by these precipitates for longer durations (if oxygen ingress had not occurred in this test).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancements to High Temperature In-Pile Thermocouple Performance

A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them to become familiar with the techniques and equipment used for specialized high temperature instrumentation fabrication and evaluation and to author/coauthor several key conference papers and journal articles.

36 MATERIALS SCIENCE↗

Enhancements to High Temperature In-Pile Thermocouple Performance

A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped lybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 °C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them to become familiar with the techniques and equipment used for specialized high temperature instrumentation fabrication and evaluation and to author/coauthor several key conference papers and journal articles.

99 GENERAL AND MISCELLANEOUS↗

HTIR-TC Compensating Extension Wire Evaluations

In an effort to reduce production costs for the doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs) recently developed by the Idaho National Laboratory, a series of evaluations were completed to identify an optimum compensating extension cable. As documented in this report, results indicate that of those combinations tested, two inexpensive, commercially-available copper nickel alloy wires approximate the low temperature (0 to 500 °C) thermoelectric output of KW-Mo (molybdenum doped with tungsten and potassium silicate) versus Nb-1%Zr in HTIR-TCs. For lower temperatures (0 to 150 °C), which is the region where soft extension cable is most often located, results indicate that the thermocouple emf is best replicated by the Cu-3.5%Ni versus Cu-5%Ni combination (measured emfs were within 4% at 100 and 150 °C). At higher temperatures (300 to 500 °C), data suggest that the Cu-5%Ni versus Cu-10%Ni combination may yield data closer to that obtained with KWMo versus Nb-1%Zr wires (measured emfs were within 8%).

36 MATERIALS SCIENCE↗