Detection of Neodymium and Surrogate Materials via Laser-Induced Fluorescence
Conference abstract being submitted by the University of Michigan in collaboration with INL
Engineering topics
Publications and source records attributed to Williams, Ammon N.
Conference abstract being submitted by the University of Michigan in collaboration with INL
NA
N/A
The accurate monitoring of molten salt is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors and pyropocessing. To attain material accountancy in actinide bearing molten salts, fluid volume and density are needed. Previous work utilized a triple bubbler sensor to measure the fluid level and density in processing tanks. This triple bubbler system utilized three gas dip-tubes strategically positioned at different heights within the molten salt such that the molten salt level, density, and surface tension were determined simultaneously. This investigation explores the effectiveness of an updated bubbler design with larger internal diameters for the dip-tubes to reduce plugging. The findings of this study will provide valuable insights into a bubbler design and configuration for applications in nuclear safeguards. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting objectives in nuclear safeguards.
A molten salt reactor (MSR) produces nuclear fission energy using mixture of fissile and non-fissile salts. Salt in the reactor functions as the nuclear material and the coolant allowing for a safer design. International nuclear safeguards is the monitoring of nuclear reactors, nuclear fuel, and irradiated material to prevent the proliferation of nuclear weapon grade material in hostile foreign nations. The mixture of salt creates a proliferation risk as it generates a conglomeration of fuel, daughter nuclei, and corrosive material. A method to monitor and measure the materials present in the reactor is essential to the scalable deployment of MSRs. The objective of this project was to design a spectroscopy apparatus for aqueous salt so it can be measured and collected consistently in the aerosol phase.
The accurate monitoring of molten salt is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors and pyropocessing. To attain material accountancy in actinide bearing molten salts, fluid volume and density are needed. Previous work utilized a triple bubbler sensor to measure the fluid level and density in processing tanks. This triple bubbler system utilized three gas dip-tubes strategically positioned at different heights within the molten salt such that the molten salt level, density, and surface tension were determined simultaneously. This investigation explores the effectiveness of an updated bubbler design with larger internal diameters for the dip-tubes to reduce plugging. The findings of this study will provide valuable insights into a bubbler design and configuration for applications in nuclear safeguards. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting objectives in nuclear safeguards.
Recent research and development in molten salt reactors (MSRs) has led to many advanced reactor designs, many of which have demonstrations planned in the next decade. However, a significant challenge that must be overcome before liquid fueled MSRs become viable globally is nuclear material accountancy (NMA) and safeguards. Liquid-fueled MSRs are problematic to safeguards because the nuclear material is in the bulk phase, inventories are constantly changing, and there are potentially many outlet pathways that must be monitored, especially in designs with online chemical processing. At the Idaho National Laboratory, we have developed a process monitoring tool to circulate molten salt through a nebulizer and optical cell, where laser-induced breakdown spectroscopy (LIBS) and ultraviolet-visible (UV-VIS) are applied to track the elemental and oxidation states of the constituents in the salt aerosol. This approach has the potential to provide information on the actinides, fission products, and corrosion in the reactor or process. Preliminary testing in aqueous praseodymium chloride (PrCl3) and neodymium chloride (NdCl3) showed good sensitivity detection limits n developed calibration curves. Additional tests and analysis or ongoing in aqueous solutions while equipment is being scaled up for high temperature molten salt testing. Results for continued testing as well as a status of the molten salt design and anticipated commissioning will be presented.
The nonproliferation of nuclear material and the development of safeguards technologies to sample and analyze fuel salt is a challenge for molten salt reactor (MSR) developers. We seek online monitoring using combined spectroscopic methods of two distinct material phases from MSR’s. Molten salt transformed to aerosol phase allows for Light Induced Breakdown spectroscopy (LIBS) without adverse splashing (ARPA-E). Vaporized used nuclear fuel through chlorine-based volatility (CBV) allows for uranium separation based on boiling point differences
Molten Salt and Off-Gas Monitoring Using Combined Spectroscopic Methods
Recent global interest in pyroprocessing and molten salt reactors has brought salt sampling methods and techniques back to the forefront of nuclear safeguards concerns. Issues with uranium supplies have also encouraged various countries to pursue advanced nuclear fuel cycles. Tracking nuclear material in molten salt has proven to be a challenge and updating molten salt sampling will greatly help in this endeavor. Molten salt is problematic to sample due to salt stratification, lack of homogeneity, solids, and difficulty with hot cell adaptations. Various salt sampling techniques have been used since before the 1960s including surface, spoon/spatula, and bar solidification. Since then, new types of sampling techniques have been developed to improve sampling results. These include rod/dip, pipet, suction, filtered sampling along with devices such as the Valve Core Sampler and the Multi-Level Sampler. These different approaches are being analyzed and improved upon along with developing requirements for an improved salt sampling device. Work continues to develop salt samplers that are more robust, easier to segment, collect at a specific depth, can work with filters, and can collect fines. Sampling parameters are also being narrowed in terms of stirring, settling time, filtration, depth, etc. In the future, we hope to address deficiencies for process control and nuclear material accountancy control by determining the best way to collect samples that minimizes contaminants and is representative. A compilation of salt sampling approaches, analyses techniques, and an evaluation of findings will be presented.
Presentation to be given at the annual review meeting for MPACT
Conference Abstract submission
None
None
Ongoing testing of the triple bubbler system has been applied to molten salt systems. The instrumentation was developed at Idaho National Laboratory for continuous monitoring of special nuclear materials in molten salt; and the instrument utilizes three dip tubes for determining the mass and volume of a liquid in a vessel. This paper will discuss the important design criteria of the bubbler probe for molten salt systems; and will describe lessons learned from using the system in a molten salt environment.