Search NASA⌕ Search

Engineering topics

Williams, B. S.

Publications and source records attributed to Williams, B. S..

Dust Removal Technolgy for a Mars In Situ Resource Utilization System

Several In Situ Resource Utilization (lSRU) systems being considered to enable future manned exploration of Mars require capture of Martian atmospheric gas to extract oxygen and other commodities. However, the Martian atmosphere contains relatively large amounts of dust which must be removed in tbe collection systems of the ISRU chambers. The amount of atmospheric dust varies largely with the presence of daily dust devils and the less frequent but much more powerful global dust storms. A common and mature dust removal technology for terrestrial systems is the electrostatic precipitator. With this technology, dust particles being captured are imparted an electrostatic charge by means of a corona discharge. Charged dust particles are then driven to a region of high electric field which forces the particles onto a collector for capture. Several difficulties appear when this technology is adapted to the Martian atmospheric environment At the low atmospheric pressure of Mars, electrical breakdown occurs at much lower voltages than on Earth and corona discharge is difficult to sustain. In this paper, we report on our efforts to obtain a steady corona/glow discharge in a simulated Martian atmosphere of carbon dioxide at 9 millibars of pressure. We also present results on the design of a dust capture system under these atmospheric conditions.

Calle, C. I.↗

Phase Locking of a 2.7 THz Quantum Cascade Laser to a Microwave Reference

We demonstrate the phase locking of a 2.7 THz metal-metal waveguide quantum cascade laser (QCL) to an external microwave signal. The reference is the 15th harmonic, generated by a semiconductor superlattice nonlinear device, of a signal at 182 GHz, which itself is generated by a multiplier chain (x 12) from a microwave synthesizer at approx. 15 GHz. Both laser and reference radiations are coupled into a bolometer mixer, resulting in a beat signal, which is fed into a phase-lock loop. The spectral analysis of the beat signal confirms that the QCL is phase locked. This result opens the possibility to extend heterodyne interferometers into the far-infrared range.

Khosropanah, P.↗

Magnetic-Field-Assisted Terahertz Quantum Cascade Laser Operating up to 225 K

Advances in semiconductor bandgap engineering have resulted in the recent development of the terahertz quantum cascade laser1. These compact optoelectronic devices now operate in the frequency range 1.2-5 THz, although cryogenic cooling is still required2.3. Further progress towards the realization of devices operating at higher temperatures and emitting at longer wavelengths (sub-terahertz quantum cascade lasers) is difficult because it requires maintaining a population inversion between closely spaced electronic sub-bands (1 THz approx. equals 4 meV). Here, we demonstrate a magnetic-field-assisted quantum cascade laser based on the resonant-phonon design. By applying appropriate electrical bias and strong magnetic fields above 16 T, it is possible to achieve laser emission from a single device over a wide range of frequencies (0.68-3.33 THz). Owing to the suppression of inter-landau-level non-radiative scattering, the device shows magnetic field assisted laser action at 1 THz at temperatures up to 215 K, and 3 THz lasing up to 225 K.

Wade, A.↗

Frequency and Phase-lock Control of a 3 THz Quantum Cascade Laser

We have locked the frequency of a 3 THz quantum cascade laser (QCL) to that of a far-infrared gas laser with a tunable microwave offset frequency. The locked QCL line shape is essentially Gaussian, with linewidths of 65 and 141 kHz at the -3 and -10 dB levels, respectively. The lock condition can be maintained indefinitely, without requiring temperature or bias current regulation of the QCL other than that provided by the lock error signal. The result demonstrates that a terahertz QCL can be frequency controlled with l-part-in-lO(exp 8) accuracy, which is a factor of 100 better than that needed for a local oscillator in a heterodyne receiver for atmospheric and astronomic spectroscopy.

Betz, A. L.↗

Ozone air broadening coefficients in the 9-micron region

Air broadening coefficients and line strengths are reported for selected ozone lines in the 8.8 to 10 micron spectral region. These parameters were obtained from a least squares fit of the Voigt line shape to experimental ozone absorption spectra obtained with a tunable diode laser. Analysis of 11 lines in the nu 1 and 18 lines in the nu 3 band suggest a transition dependent coefficient, although no definitive relationship was identified. The average air broadening coefficient for the nu 1 and nu 3 ozone lines is 0.077 and 0.083 per cm/atm, respectively. The measured line strengths are typically 10% to a factor of 2 larger than those given in the AFGL compilation.

Hoell, J. M.↗

Remote infrared heterodyne radiometer measurements of atmospheric ammonia profiles

An infrared heterodyne radiometer has been used to study the seasonal variation of the vertical distribution of atmospheric ammonia. The ammonia profiles are inferred from high-resolution atmospheric solar transmittance measurements around the ammonia absorption feature at 927.32323 kaysers. The transmittance data are obtained from six IF channels with spectral resolutions ranging from .0067 to .033 kaysers. Results from this study show a marked decrease in the tropospheric ammonia level with a decrease at ground level from approximately 10 ppb in March 1979 to 1.3 ppb in August 1979.

Hoell, J. M.↗