Search NASA⌕ Search

Engineering topics

Williams, Darrick

Publications and source records attributed to Williams, Darrick.

Perovskite Grown in Gallium Nitride Nanowire Matrix for Stable and High‐Efficiency X‐Ray Detection

High-quality quasi-2D perovskites in a GaN nano-wire matrix are grown to build a 3D hetero-structure for high-performance X-ray sensing. In the 3D hetero-structure, GaN nano-wire matrix serves as an n-type charge collector that can rapidly extract carriers through the bulk film of the perovskite layer. Together with a p-type top electrode, a p–i–n diode with the 3D hetero-structure is built, that exhibits a rectified current–voltage characteristic. After analyzing the interface energy alignment, it is found that the fermi levels of the perovskite and GaN are aligned in the dark, and a quasi-fermi level splits upon illumination, introducing a built-in electrical field at the interface. As a result, strong photo-induced current is observed from the diode without an external field. Finally, the 3D diode for X-ray detection demonstration is used, revealing a sensitivity of 308.9 µC Gy air -1 cm -2 at an exceptionally low applied field of 0.125 V µm -1 . The X-ray-induced signal from the 3D diode is stable after 155 cycles of X-ray irradiation under a constant electric field. This demonstration informs a new 3D architecture for high-performance X-ray sensing, and it shows that GaN is a robust n-type interface for perovskite optoelectronic devices.

36 MATERIALS SCIENCE↗

Quasi‐2D Perovskite Crystalline Layers for Printable Direct Conversion X‐Ray Imaging

Abstract Polycrystalline perovskite film‐based X‐ray detector is an appealing technology for assembling large scale imager by printing methods. However, thick crystalline layer without trap and solvent residual is challenging to fabricate. Here, the authors report a solution method to produce high quality quasi‐2D perovskite crystalline layers and detectors that are suitable for X‐ray imaging. By introducing n ‐butylamine iodide into methylammonium lead iodide precursor and coating at elevated temperatures, compact and crystalline layers with exceptional uniformity are obtained on both rigid and flexible substrates. Photodiodes built with the quasi‐2D layers exhibit a low dark current and stable operation under constant electrical field over 96 h in dark, and over 15 h under X‐ray irradiation. The detector responds sensitively under X‐ray, delivering a high sensitivity of 1214 µC Gy air −1 cm −2 and a sensitivity gain is observed when operated under higher fields. Finally, high resolution images are demonstrated using a single pixel device that can resolve 80–200 µm features. This work paves the path for printable direct conversion X‐ray imager development.

36 MATERIALS SCIENCE↗