Search NASASearch

Engineering topics

Williams, James H.

Publications and source records attributed to Williams, James H..

Pressure Flammability Thresholds of Selected Aerospace Materials

A test program was performed to determine the highest pressure in oxygen where materials used in the planned NASA Constellation Program Orion Crew Exploration Vehicle (CEV) Crew Module (CM) would not propagate a flame if an ignition source was present. The test methodology used was similar to that previously used to determine the maximum oxygen concentration (MOC) at which self-extinguishment occurs under constant total pressure conditions. An upward limiting pressure index (ULPI) was determined, where approximately 50 percent of the materials self-extinguish in a given environment. Following this, the maximum total pressure (MTP) was identified; where all samples tested (at least five) self-extinguished following the NASA-STD-6001.A Test 1 burn length criteria. The results obtained on seven materials indicate that the non-metallic materials become flammable in oxygen between 0.4 and 0.9 psia.

Hirsch, David B.

Pressure Effects on the Self-Extinguishment Limits of Aerospace Materials

The Orion Crew Exploration Vehicle Module (CM) is being designed to operate in an atmosphere of up to 30% oxygen at a pressure of 10.2 psia for lunar missions. Spacecraft materials selection is based on an upward flammability test conducted in a closed chamber under the worst expected conditions of pressure and oxygen concentration. Material flammability depends on both oxygen concentration and pressure but, since oxygen concentration is the primary driver, all materials are certified in the 30% oxygen, 10.2 psia environment. Extensive data exist from the Shuttle Program at this condition which used relatively the same test methodology as currently used in the Constellation Program. When the CM returns to Earth, a snorkel device will be activated after splashdown to provide outside air to the crew; however, for operational reasons, it is desirable to maximize the time the crew is able to breathe cabin air before the snorkel device is activated. To maximize this time, it has been proposed to raise the partial pressure of oxygen in the CM immediately before reentry while maintaining the total cabin pressure at 14.7 psia. In addition, it has been proposed to leak-test the Orion CM with ambient air at a maximum pressure of 17.3 psia. No data exist to assess how high the cabin oxygen concentration can be at 14.7 psia or 17.3 psia. One is to re-test a large number of materials at these pressures at a significant cost. However, since the maximum oxygen concentration (MOC) at which a material will self-extinguish has been determined for a variety of spacecraft materials as a function of pressure, a second alternative is to use existing data to estimate the MOC at 14.7 psia and 17.3 psia. This data will be examined in this paper and an analysis presented to determine the oxygen concentrations at the increased pressures that will result in self-extinguishment of a material. This analysis showed that the oxygen concentration for the Orion CM at 14.7 psia cannot be set higher than 25.6% without potentially invalidating the materials flammability certification in 30% oxygen at 10.2 psia for some materials. Materials certified under these conditions would still be self-extinguishing in ambient air at 17.3 psia. alternative

Hirsch, David B.

Oxygen Concentration Flammability Thresholds of Selected Aerospace Materials Considered for the Constellation Program

Materials selection for spacecraft is based on an upward flammability test conducted in a quiescent environment in the highest expected oxygen concentration environment. The test conditions and its pass/fail test logic do not provide sufficient quantitative materials flammability information for an advanced space exploration program. A modified approach has been suggested determination of materials self-extinguishment limits. The flammability threshold information will allow NASA to identify materials with increased flammability risk from oxygen concentration and total pressure changes, minimize potential impacts, and allow for development of sound requirements for new spacecraft and extraterrestrial landers and habitats. This paper provides data on oxygen concentration self-extinguishment limits under quiescent conditions for selected materials considered for the Constellation Program.

Hirsch, David B.

Oxygen Concentration Flammability Threshold Tests for the Constellation Program

CEV atmosphere will likely change because craft will be used as LEO spacecraft, lunar spacecraft, orbital spacecraft. Possible O2 % increase and overall pressure decrease pressure vessel certs on spacecraft. Want 34% minimum threshold. Higher, better when atmosphere changes. WSTF suggests testing all materials/components to find flammability threshold, pressure and atmosphere.

Williams, James H.

Reactivities of Precision Cleaning Solvents with Hypergolic Propellants

The reactivities of several selected halogenated precision cleaning solvents with hypergolic propellants has been determined by analysis of the rates of formation of halide ion decomposition products. The solvents were Asahiklin AK 225, Asahiklin AK 225 AES, HFE 7100, HFE 7100 DE, Vertrel XF, Vertrel MCA, Vertrel MCA Plus, 1,1,2-trichloro-1,2,2-trifluoroethane (CFC-113), and trans-1,2-dichloroethylene (DCE). The propellants were hydrazine (HZ), monomethylhydrazine (MMH), and mixed oxides of nitrogen (MON-3). The Vertrel solvents showed significant reactivity with HZ. All of the solvents except DCE exhibited significant reactivity with MMH, particularly HFE 7100 DE and CFC-113. HFE 7100 DE, Vertrel MCA, and Vertrel MCA Plus also showed significant reactivity with MON-3 oxidizer.

Davis, Dennis D.

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.