Search NASA⌕ Search

Engineering topics

Williams, M. L.

Publications and source records attributed to Williams, M. L..

At least 19 records

Development and testing of neutron cross-section covariance data for Scale 6.2 - 14604

Neutron cross-section covariance data are essential for many sensitivity/uncertainty and uncertainty quantification assessments performed both within the TSUNAMI suite and more broadly throughout the SCALE code system. The release of ENDF/B-VII.1 included a more complete set of neutron cross-section covariance data: these data form the basis for a new cross-section covariance library to be released in SCALE 6.2. A range of testing is conducted to investigate the properties of these covariance data and ensure that the data are reasonable. These tests include examination of the uncertainty in critical experiment benchmark model k{sub eff} values due to nuclear data uncertainties, as well as similarity assessments of irradiated pressurized water reactor (PWR) and boiling water reactor (BWR) fuel with suites of critical experiments. The contents of the new covariance library, the testing performed, and the behavior of the new covariance data are described in this paper. The neutron cross-section covariances can be combined with a sensitivity data file generated using the TSUNAMI suite of codes within SCALE to determine the uncertainty in system k{sub eff} caused by nuclear data uncertainties. The Verified, Archived Library of Inputs and Data (VALID) maintained at Oak Ridge National Laboratory (ORNL) contains over 400 critical experiment benchmark models, and sensitivity data are generated for each of these models. The nuclear data uncertainty in k{sub eff} is generated for each experiment, and the resulting uncertainties are tabulated and compared to the differences in measured and calculated results. The magnitude of the uncertainty for categories of nuclides (such as actinides, fission products, and structural materials) is calculated for irradiated PWR and BWR fuel to quantify the effect of covariance library changes between the SCALE 6.1 and 6.2 libraries. One of the primary applications of sensitivity/uncertainty methods within SCALE is the assessment of similarities between benchmark experiments and safety applications. This is described by a ck value for each experiment with each application. Several studies have analyzed typical ck values for a range of critical experiments compared with hypothetical irradiated fuel applications. The ck value is sensitive to the cross-section covariance data because the contribution of each nuclide is influenced by its uncertainty; large uncertainties indicate more likely bias sources and are thus given more weight. Changes in ck values resulting from different covariance data can be used to examine and assess underlying data changes. These comparisons are performed for PWR and BWR fuel in storage and transportation systems. (authors)

42 ENGINEERING↗

AMPX: A Modern cross section processing system for generating nuclear data libraries - 14619

Nuclear data libraries are essential for nuclear analysis code systems like SCALE. AMPX has been continuously developed since the early 1970's and is used to generate these data libraries for SCALE. Recently, Oak Ridge National Laboratory (ORNL) initiated a major modernization effort to position AMPX for continued development and deployment on modern computing platforms. An important step toward modernization has been to merge AMPX under the SCALE continuous integration (CI) development framework. As a result, AMPX is now developed under the SCALE software quality assurance plan, providing increased confidence in the quality of data libraries developed and deployed by AMPX. This merge allowed us to develop novel methods to generate self-shielding factors that combine SCALE's resonance self-shielding capabilities with the AMPX library-generation capabilities. AMPX processes Evaluated Nuclear Data Format (ENDF/B) files. The ENDF community is working to develop a more modern format that will replace the existing ENDF/B format. Due to strict space and memory requirements when AMPX was first developed, the original AMPX processing and reading of ENDF data were tightly integrated. On newer computer systems, this is no longer necessary. Now there is a separation between reading and processing which allows for simultaneous support of current and new ENDF formats. As a result, AMPX is positioned to adopt any new ENDF format when available. For end users, the modernization effort has resulted in improved processing capabilities for generating nuclear data libraries. The objective of the paper is to document the latest AMPX cross-section processing capabilities and provide the current status of the AMPX modernization effort. (authors)

42 ENGINEERING↗

Faired instrumentation for aerodynamic tests

Streamlined package is installed and removed without altering aerodynamic properties of structure being tested. Method uses lightweight materials so that blade balance is maintained.

Long, W. C.↗

A rotor-mounted digital instrumentation system for helicopter blade flight research measurements

A rotor mounted flight instrumentation system developed for helicopter rotor blade research is described. The system utilizes high speed digital techniques to acquire research data from miniature pressure transducers on advanced rotor airfoils which are flight tested on an AH-1G helicopter. The system employs microelectronic pulse code modulation (PCM) multiplexer digitizer stations located remotely on the blade and in a hub mounted metal canister. As many as 25 sensors can be remotely digitized by a 2.5 mm thick electronics package mounted on the blade near the tip to reduce blade wiring. The electronics contained in the canister digitizes up to 16 sensors, formats these data with serial PCM data from the remote stations, and transmits the data from the canister which is above the plane of the rotor. Data are transmitted over an RF link to the ground for real time monitoring and to the helicopter fuselage for tape recording. The complete system is powered by batteries located in the canister and requires no slip rings on the rotor shaft.

Knight, V. H., Jr.↗

Mixed mode stress field effect in adhesive fracture

Numerical or analytical analyses were performed on seven different test specimens including blister test, 90-degree peel test, torsion test, and various cone tests. These specimens are in general subjected to complex stress fields having various amounts of Mode I, Mode II, and Mode III loads. The specimens were then constructed using polymethyl methacrylate for the adherends and a transparent polyurethane elastomer (Solithane 113) for the adhesive. This combination permitted direct observation of the bondline as load was applied. Although initial debonds as well as bond end termination singularities were present in all specimens, in some cases the debond did not initiate at the singularity points as would normally have been expected. An explanation for this behavior is presented, as well as a comparison of loading mode effect on those specimens for which the debond did propagate from a bond terminus singular point.

Anderson, G. P.↗

The peel test in experimental adhesive fracture mechanics

Several testing methods have been proposed for obtaining critical energy release rate or adhesive fracture energy in bond systems. These tests include blister, cone, lap shear, and peel tests. Peel tests have been used for many years to compare relative strengths of different adhesives, different surface preparation techniques, etc. The present work demonstrates the potential use of the peel test for obtaining adhesive fracture energy values.

Anderson, G. P.↗

Adhesive fracture mechanics

In studies of fracture mechanics the adhesive fracture energy is regarded as a fundamental property of the adhesive system. It is pointed out that the value of the adhesive fracture energy depends on surface preparation, curing conditions, and absorbed monolayers. A test method reported makes use of a disk whose peripheral part is bonded to a substrate material. Pressure is injected into the unbonded central part of the disk. At a certain critical pressure value adhesive failure can be observed. A numerical stress analysis involving arbitrary geometries is conducted.

Bennett, S. J.↗

The effects of plasticity in adhesive fracture

An energy-balance analysis is presented for adhesive failure in end loaded cantilever beams. The analysis includes the effects of input work, stored strain energy, dissipated plastic energy, and specific adhesive surface energy. Experimental results obtained with 6061-T6 aluminum are presented as evidence for the validity of the approach.-

Chang, M. D.↗

A fracture mechanics analysis of adhesive failure in a single lap shear joint.

Discussion of adhesive fracture of single lap shear joints in terms of a maximum stress criterion and an energy balance. The Goland and Reissner (1944) analysis is used to determine the stress distribution in the adhesive assembly, and the results obtained are introduced into an energy balance to determine the initiation of adhesive fracture. In the stress analysis the loads at the edges of the joint are first determined. This is a problem in which the deformation of the joint sheets must be taken into account and is solved by using the finite-deflection theory of cylindrically bent plates. Then the stress in the joint due to applied loads is determined. This problem is formulated as one in plane strain consisting of two rectangular sheets of equal thickness and unit width. With the aid of this stress analysis and the stresses obtained from the conditions of equilibrium the contributions to the energy change with crack length are calculated. The analysis performed is then compared with a maximum stress criterion for a lap joint.

Devries, K. L.↗

EPR-atomic scale experimental stress analysis

Electron paramagnetic resonance atomic scale stress analysis of high polymer fibers and rubber, measuring chain scission and bond rupture for different loading histories

Devries, K. L.↗

Formation of free radicals during mechanical degradation of elastomers.

Solithane 113 (an amorphous polyurethane elastomer) was prepared by curing equal proportions of castor oil and trifunctional isocyanate for 6 hr 45 min at 170 F. The sample material was mechanically degraded by grinding below and above its glass transition point at liquid nitrogen and room temperatures. The EPR spectra of ground samples were recorded and the number of free radicals were determined by a computer double-integration of the recorded spectra and by a comparison of the values with those of a standard material. Curves of EPR spectra suggest that different molecular mechanisms may be active in degradation of this material below and above its glass transition temperature.

Devries, K. L.↗