Search NASA⌕ Search

Engineering topics

Wilson, B. G.

Publications and source records attributed to Wilson, B. G..

At least 19 records

Milestone 7714 National Opacity Program: High-Fidelity Iron Data on NIF

Establish the level of reproducibility of NIF iron opacity shots, quantify to-date improvements in data quality through, e.g. background reduction, improved signal, and improved analysis methods, and formalize the approach that will be taken in the future to compare NIF data, Z data, and theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Progress toward NIF opacity measurements

The opacities of iron and other mid-Z elements help to regulate the transport of energy in the sun. Recent experiments on the Sandia National Laboratories Z machine have shown large discrepancies between the measured and calculated opacities of iron at certain solar conditions. To replicate these opacity measurements a platform is being developed on the National Ignition Facility to measure the opacities of iron and other elements at the same conditions as in the Z experiments. The NIF platform consists of a hohlraum to heat the opacity sample to the desired conditions, a separate backlighter to radiograph the sample, and a spectrometer to give the spectrally resolved opacity. Not only must the opacity be measured but the temperature and density of the sample must also be accurately determined. This platform has now produced its first iron transmission measurements. Overall, these measurements will be presented along with plans for future measurements and details on how the measurements will be improved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First systematic study of L-shell opacity at stellar interior temperatures

The first systematic study of opacity dependence on atomic number at stellar interior temperatures is used to evaluate discrepancies between measured and modeled iron opacity [J. E. Bailey et al., Nature (London) 517, 56 (2015)]. High-temperature ( > 180 eV) chromium and nickel opacities are measured with ± 6-10% uncertainty, using the same methods employed in the previous iron experiments. The 10%-20% experiment reproducibility demonstrates experiment reliability. The overall model-data disagreements are smaller than for iron. However, the systematic study reveals shortcomings in models for density effects, excited states, and open L-shell configurations. The 30%-45% underestimate in the modeled quasicontinuum opacity at short wavelengths was observed only from iron and only at temperature above 180 eV. Thus, either opacity theories are missing physics that has nonmonotonic dependence on the number of bound electrons or there is an experimental flaw unique to the iron measurement at temperatures above 180 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗

Update on the Iron Opacity Experiments on the NIF

Recent iron opacity experiments on the Sandia National Laboratories Z machine have reported up to factors of two discrepancies between theoretical and experimental results. Much effort has been invested in identifying experimental errors as well as revisiting opacity theories, but a resolution of the discrepancies has not been forthcoming. Here, we emphasize the discrepancies present a fundamental theoretical challenge. To help resolve this question, an experimental platform for opacity experiments is being developed at the National Ignition Facility (NIF). This platform will be able to replicate the experimental conditions of the Z experiments and also extend the measurements to other temperatures and densities. Experiments to date have demonstrated a satisfactory X-ray backlighting source and have achieved the appropriate plasma conditions in the opacity sample. Some initial iron data have been taken, but problems remain with backgrounds and with the spectrometer used to make the measurements.The path forward for correcting these problems is presented.We expect that data for comparing with the Z experiments will be available within a year.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development on the National Ignition Facility of a High Energy Density Opacity Platform

X-ray opacity is a crucial factor in all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in simulation codes for high-energy-density plasmas. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment for various mid-Z elements (Fe, Cr, Ni). These discrepancies raise doubts regarding the accuracy of the opacity models which are used in ICF and stewardship as well as in astrophysics. Therefore, a new experimental opacity platform has been developed on the National Ignition Facility (NIF), not only to verify the Z-machine experimental results, but also to extend the experiments to other temperatures and densities. Within the context of the national opacity strategy, the first NIF experiments were directed towards measuring the opacity of iron at a temperature of ~160 eV and an electron density of ~7xl021 cm-3(Anchor 1). The Z data agree with theory at these conditions, providing a reference point for validation of the NIF platform. Development shots on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule, and also a combined hohlraum, sample and laser drive able to produce iron plasmas at the desired conditions. Spectrometer qualification has been completed, albeit with additional improvements planned, and the first iron absorption spectra have now been obtained.

36 MATERIALS SCIENCE↗

Replicating the Z iron opacity experiments on the NIF

Here, X-ray opacity is a crucial factor of all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in the simulation codes. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment, casting doubt on the validity of the opacity models. Therefore, a new experimental opacity platform is being developed on the National Ignition Facility (NIF) not only to verify the Z-machine experimental results but also to extend the experiments to other temperatures and densities. The first experiments will be directed towards measuring the opacity of iron at a temperature of ~160 eV and an electron density of ~7 x 10 21 cm -3 . Preliminary experiments on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule and also a hohlraum that can heat the opacity sample to the desired conditions. The first of these iron opacity experiments is expected to be performed in 2017.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of initial opacity experiments on the national ignition facility

Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative–convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures ${\geqslant}150$ eV and electron densities ${\geqslant}7\times 10^{21}~\text{cm}^{-3}$ . The iron will be probed using continuum X-rays emitted in a ${\sim}200$ ps, ${\sim}200~\unicode[STIX]{x03BC}\text{m}$ diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, $2/3$ of the NIF beams deliver 500 kJ to the ${\sim}6$ mm diameter hohlraum, and the remaining $1/3$ directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comment on “Large Enhancement in High-Energy Photoionization of Fe XVII and Missing Continuum Plasma Opacity”

Recent R-matrix calculations claim to provide a significant enhancement in the opacity of Fe XVII due to atomic core excitations and assert that this enhancement is consistent with recent measurements of higher-than-predicted iron opacities. Here this comment shows that the standard opacity models which have already been directly compared with experimental data produce photon absorption cross-sections for Fe XVII that are effectively equivalent to the R-matrix opacities reported in.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗