Search NASA⌕ Search

Engineering topics

Wilt, Michael

Publications and source records attributed to Wilt, Michael.

3D modeling of deep borehole electromagnetic measurements with energized casing source for fracture mapping at the Utah Frontier Observatory for Research in Geothermal Energy

Here, we present a 3D numerical modelling analysis evaluating the deployment of a borehole electromagnetic measurement tool to detect and image a stimulated zone at the Utah Frontier Observatory for Research in Geothermal Energy geothermal site. As the depth to the geothermal reservoir is several kilometres and the size of the stimulated zone is limited to several 100 m, surface-based controlled-source electromagnetic measurements lack the sensitivity for detecting changes in electrical resistivity caused by the stimulation. To overcome the limitation, the study evaluates the feasibility of using a three-component borehole magnetic receiver system at the Frontier Observatory for Research in Geothermal Energy site. To provide sufficient currents inside and around the enhanced geothermal reservoir, we use an injection well as an energized casing source. To efficiently simulate energizing the injection well in a realistic 3D resistivity model, we introduce a novel modelling workflow that leverages the strengths of both 3D cylindrical-mesh-based electromagnetic modelling code and 3D tetrahedral-mesh-based electromagnetic modelling code. The former is particularly well-suited for modelling hollow cylindrical objects like casings, whereas the latter excels at representing more complex 3D geological structures. In this workflow, our initial step involves computing current densities along a vertical steel-cased well using a 3D cylindrical electromagnetic modelling code. Subsequently, we distribute a series of equivalent current sources along the well's trajectory within a complex 3D resistivity model. We then discretize this model using a tetrahedral mesh and simulate the borehole electromagnetic responses excited by the casing source using a 3D finite-element electromagnetic code. This multi-step approach enables us to simulate 3D casing source electromagnetic responses within a complex 3D resistivity model, without the need for explicit discretization of the well using an excessive number of fine cells. We discuss the applicability and limitations of this proposed workflow within an electromagnetic modelling scenario where an energized well is deviated, such as at the Frontier Observatory for Research in Geothermal Energy site. Using the workflow, we demonstrate that the combined use of the energized casing source and the borehole electromagnetic receiver system offer measurable magnetic field amplitudes and sensitivity to the deep localized stimulated zone. The measurements can also distinguish between parallel-fracture anisotropic reservoirs and isotropic cases, providing valuable insights into the fracture system of the stimulated zone. Besides the magnetic field measurements, vertical electric field measurements in the open well sections are also highly sensitive to the stimulated zone and can be used as additional data for detecting and imaging the target. We can also acquire additional multiple-source data by grounding the surface electrode at various locations and repeating borehole electromagnetic measurements. This approach can increase the number of monitoring data by several factors, providing a more comprehensive dataset for analysing the deep-localized stimulated zone. The numerical analysis indicates that it is feasible to use the combination of the energized casing and downhole electromagnetic measurements in monitoring localized stimulated zone at large depths.

58 GEOSCIENCES↗

Enhanced Multi-Dimensional Inversion Through Target-Specific Inversion Parameter Bounds With an Application to Crosswell Electromagnetic for Sequestration Monitoring

In geophysical inversions, lower and upper model parameter bounds are a means of solution stabilization. Further, constraints that intend to let only geologically plausible inverse solutions pass are amenable to lower and upper bounds. Reliable prior information is paramount to construct such bound constraints. It is common practice to narrow and widen bound intervals for regions of, respectively, more and less certain prior information. Contrary to this practice, we experiment with widened bound intervals in zones that are poorly resolved by a given survey configuration but where prior information would suggest structural anomalies of interest. The purpose of enlarged parameter bounds that correlate spatially with predefined targets is to let the inversion explore a larger solution space, thus increasing the potential to resolve otherwise hidden anomalies. Application of the method is based on a carbon-sequestration baseline (pre-injection) crosswell electromagnetic (EM) field survey at the Containment and Monitoring Institute Field Research Station (Alberta, Canada), where impeded measurements led to generally reduced sensitivities for the interwell region. Synthetic-data proofs of concept use augmented bounds designed to boost the resolution of artificial plume targets, indicating an enhanced illumination compared to constant bounds. Comparative field data inversions with spatially variable bounds constructed from prior resistivity and velocity information highlight non-horizontal baseline structures.

3-D electrical resistivity imaging↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

The effects of well damage and completion designs on geoelectrical responses in mature wellbore environments

Well integrity is one of the major concerns in long-term geologic storage sites due to the potential risk of well leakage and groundwater contamination. Evaluating changes in electrical responses due to energized steel-cased wells has the potential to quantify and predict possible wellbore failures because any kind of breakage or corrosion along highly conductive well casings will have an impact on the distribution of the subsurface electrical potential. However, realistic wellbore-geoelectrical models that can fully capture fine-scale details of well completion design and the state of well damage at the field scale require extensive computational effort, or they can even be intractable to simulate. To overcome this computational burden while still keeping the model realistic, we have used the hierarchical finite-element method that represents electrical conductivity at each dimensional component (1D edges, 2D planes, and 3D cells) of a tetrahedral mesh. This allows well completion designs with real-life geometric scales and well systems with realistic, detailed, progressive corrosion and damage in our models. We have developed a comparison of possible discretization approaches of a multicasing completion design in the finite-element model. The effects of the surface casing and the coupling between concentric well casings as well as the effects of the degree and the location of well damage on the electrical responses are also examined. As a result, we analyze real surface electric field data to detect wellbore integrity failure associated with damage.

58 GEOSCIENCES↗

An adaptable technique for comparative image assessment: Application to crosswell electromagnetic survey design for fluid monitoring

Reservoir integrity stewardship accompanying carbon capture and sequestration considers fluid extraction and reinjection as a risk-mitigating method against overpressuring that could lead to caprock damage and ensuing [Formula: see text] leakage. Crosswell electromagnetics offers a technically viable monitoring method with the spatial volume coverage necessary for reservoir-encompassing pressure management. However, a certain logistic dilemma for deep gas sequestration into saline and thus electrically conductive aquifers is that crosswell magnetic-field measurements underperform in the imaging of more resistive plume bodies, further exacerbated when vertical arrays intersect, as opposed to surround, plumes. Furthermore, comparative synthetic-data plume imaging of such scenarios rates the information content of magnetic-field versus electric-field 3D crosswell layouts for reservoir and infrastructure conditions of a representative pilot site in a coastal area in Florida. The image quality of the resulting plume replications can be ranked numerically through a newly proposed semblance qualifier, appraising the model goodness of fit to a given reference. In contrast to common least-squares measures for goodness of fit, the semblance formulation uses classifying logistic function types, thus enabling a better distinction of predefined anomaly features.

58 GEOSCIENCES↗

WISE-CASING: Frequency Domain EM Data from Cymric Oil Field, CA

Cymric oil field frequency domain electromagnetic (FEM) data with two parts of data labeled Part 1 and Part 2. Part 1 utilizes an electrical source line parallel to the receiver line, while Part 2 utilizes an electrical source line at a 75 deg angle to the receiver line. Data are plotted and compared to numerically modeled data to observe electric field response to well structure. In two configuration files are diagrams of the experiment layout.

15 GEOTHERMAL ENERGY↗

WISE-CASING: Containment and Monitoring Institute (CaMI), Calgary, Canada FEM-DC Model

For the model calculation we applied EM3D using completion diagram of CaMI site and a background resistivity consistent with the borehole logs. It was also important to use the accurate position of the return electrode. We note that for the data fit the code also incorporated well casings for well INJ and the other observation well, either OB1 or OB2, in the calculation. In summary, we demonstrate here, for this particular case, that the DC results may be a reasonable approximation to the low frequency EM data collected at CaMI. If this approximation continues to hold, then the extreme computational efficiency offered by the hierarchical modeling used in the DC simulations will permit us to explore far more model complexity, especially the pervasive and troublesome data artifacts that arise when doing EM surveys in mature, culturally developed sites. In Brief, both the low frequency and DC simulation codes provided very consistent results that match the field data really well, indicating their capability to help monitoring borehole integrity with the low frequency EM method.

15 GEOTHERMAL ENERGY↗

Casing-integrity mapping using top-casing electrodes and surface based EM fields

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage and hazardous waste disposal. We introduce a simple non-invasive technology for casing integrity screening, based on the continuity of electrical current flow. Applying low frequency current to a wellhead, with a distant return electrode, produces a casing current dependent on the properties and depth extent of the well casing as well as the background formation. These currents in-turn generate surface electrical fields that can be captured in a radial profile and be used to analyze properties of the well casing. Numerical modeling results reveal a strong relation of the electric field to the casing properties and depth extent of the well. A small breakage in the casing produces a profile coincident to a cased well with a completion depth above the break. A corroded patch, where the casing conductivity is reduced, also alters the field profiles and its depth may be estimated by comparing to the profile expected from the well completion diagrams. The electric field profiles are also strongly dependent on background resistivity distributions and on whether the well was drilled using water or oil-based drilling fluids. We validate the proof of concept in a field experiment, where we applied currents at the wellheads of two wells with different casing lengths. The two profiles were similar in appearance but offset in amplitude by more than a factor of 5, consistent with the theoretical analysis as well as the 3D modeling results. These results demonstrate that our proposed approach has promise for mapping the general casing condition without well intervention. This approach can be a practical and effective tool for rapidly screening a number of wells before expensive logging-based technologies are employed for casing inspection in detail.

58 GEOSCIENCES↗

Evaluation of Deep Subsurface Resistivity Imaging for Hydrofracture Monitoring

This report describes the results of the first of its kind monitoring of a hydrofracture operation with electromagnetic measurements. The researchers teamed with oil and gas producer Encana Corporation to design and execute a borehole to surface monitoring of three fracture stages at a well pad in central Colorado. The field project consisted of an equipment upgrade, a survey design and modeling phase, several weeks of data collection, and data processing and interpretation. Existing Depth to Surface Resistivity (DSR) instrumentation was upgraded to allow for continuous high precision recording from downhole sources. The full system can now collect data continuously for up to 72 hours, which is sufficient to measure data for 10 frac stages. Next we used numerical modeling and frac treatment data supplied by Encana to design a field survey to detect EM signal from induced fractures. Prior to modeling we developed a novel technique for using well casing as an antenna for a downhole source. Modeling shows that 1) a measurable response for an induced fracture could be achieved if the facture fluid was of high salinity 2) an optimum fracture response is created when the primary source field is parallel to the well casing but perpendicular to the fracture direction. In mid-July, 2014 we installed an array of more than 100 surface sensors, distributed above the treatment wells and extending for approximately 1 km north and 750 m eastward. We applied a 0.6 Hz square wave signal to a downhole current electrode located in a horizontal well 200 m offset from the treatment well with a return electrode on the surface. The data were transmitted to a recording trailer via Wi-Fi where we monitored receiver and transmitter channels continuously in a 72-hour period which covered 7 frac stages, three of which were high salinity. Although the background conditions were very noisy we were able to extract a clear signal from the high salinity stages. Initial data interpretation attempts consisting of trying to directly invert collected data using a simple background starting model did not produce reasonable models. We next used a simulated data set to develop a constrained inversion workflow that places the downhole fracture in the correct location. Finally, we used a combination of forward and inverse models to fit the collected data to a model that incorporated 3 frac stages. This project provided a first-of-its-kind application of EM technology to map an induced fracture. The results demonstrated a clear anomaly during the operation that can be fit to a reasonable model of an induced fracture.

42 ENGINEERING↗

Using well casing as an electrical source to monitor hydraulic fracture fluid injection

The depth to surface resistivity (DSR) method transmits current from a source located in a cased or openhole well to a distant surface return electrode while electric field measurements are made at the surface over the target of interest. This paper presents both numerical modelling results and measured data from a hydraulic fracturing field test where conductive water was injected into a resistive shale reservoir during a hydraulic fracturing operation. Modelling experiments show that anomalies due to hydraulic fracturing are small but measureable with highly sensitive sensor technology. The field measurements confirm the model results,showing that measured differences in the surface fields due to hydraulic fracturing have been detected above the noise floor. Our results show that the DSR method is sensitive to the injection of frac fluids; they are detectable above the noise floor in a commercially active hydraulic fracturing operation, and therefore this method can be used for monitoring fracture fluid movement.

02 PETROLEUM↗