Search NASA⌕ Search

Engineering topics

Winters, C.

Publications and source records attributed to Winters, C..

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible polymer-based luminescent ink for combined thermographic phosphors and digital image correlation (TP+DIC)

Recent work on the development of integrated thermographic phosphors and digital image correlation (TP+DIC) for combined thermal–mechanical measurements has revealed the need for a flexible, stretchable phosphor coating for metal surfaces. Herein, we coat stainless steel substrates with a polymer-based phosphor ink in a DIC speckle pattern and demonstrate that the ink remains well bonded under substrate deformation. In contrast, a binderless phosphor DIC coating produced via aerosol deposition (AD) partially debonded from the substrate. DIC calculations reveal that the strain on the ink coating matches the strain on the substrate within 4% error at the highest substrate loads (0.05 mm/mm applied substrate strain), while the strain on the AD coating remains near 0 mm/mm as the substrate deforms. Spectrally resolved emission from the phosphor is measured through the transparent binder throughout testing, and the ratio method is used to infer temperature with an uncertainty of 1.7 °C. In conclusion, this phosphor ink coating will allow for accurate, non-contact strain and temperature measurements of a deforming surface.

36 MATERIALS SCIENCE↗

Energy dispersive x-ray diffraction of luminescent powders: A complement to visible phosphor thermometry

Energy-dispersive x-ray diffraction of thermographic phosphors has been explored as a complementary temperature diagnostic to visible phosphor thermometry in environments where the temperature-dependent optical luminescence of the phosphors is occluded. Powder phosphor samples were heated from ambient to 300°C in incremental steps and probed with polychromatic synchrotron x rays; scattered photons were collected at a fixed diffraction angle of 3.9°. Crystal structure, lattice parameters, and coefficients of thermal expansion were calculated from the diffraction data. Finally, of the several phosphors surveyed, YAG:Dy, ZnO:Ga, and GOS:Tb were found to be excellent candidates for diffraction thermometry due to their strong, distinct diffraction peaks that shift in a repeatable and linear manner with temperature.

47 OTHER INSTRUMENTATION↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗