Search NASA⌕ Search

Engineering topics

Winters, Caroline

Publications and source records attributed to Winters, Caroline.

At least 19 records

Ultrafast Surface Phosphor Thermometry for Pulsed-power and Hostile Environments

Modern concepts for next generation pulsed power (NGPP) are slated to deliver up to ten times the energy of Z today. An increase of this magnitude is concerning insofar that Z currently exhibits sizable amounts of inner magnetically insulated transmission line (MITL) loss current on the order of 5-10%. Loss phenomenon in these systems are complex and electrode heating and subsequent thermal desorption are a leading cause. Rapid heat-driven thermal desorption of contaminants scales as the square of the current. Therefore, even a modest doubling of drive current would yield an ~ 4X in non-linear surface electrode heating, quickening thermal desorption-based current loss. Exacerbating these physics is a current inability to measure ultra fast heating rates (>20°C/ns), which are paramount to benchmarking and code validation critical to NGPP design – as an empirical approach is not viable. Therefore, Ultrafast Photoluminescent Surface Heating Optical Thermometry (UP-SHOT) was developed as a new diagnostic for measurement of GHz-scale electrode heating. The discovery of UP-SHOT leveraged expertise in Engineering Science, Material Science, Pulsed-Power, and the Center for Integrated Nanotechnologies. This report includes information on: 1) The preparation of zinc oxide (ZnO) films, characterization, post-deposition treatments 2) Time-resolved photoluminescence at elevated temperatures and thermographic sensitivity

36 MATERIALS SCIENCE↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗