Search NASA⌕ Search

Engineering topics

Winz, G. R.

Publications and source records attributed to Winz, G. R..

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

Multi-point, high-speed passive ion velocity distribution diagnostic on the Pegasus Toroidal Experiment

A passive ion temperature polychromator has been deployed on Pegasus to study power balance and non-thermal ion distributions that arise during point source helicity injection. Spectra are recorded from a 1 m F/8.6 Czerny-Turner polychromator whose output is recorded by an intensified high-speed camera. The use of high orders allows for a dispersion of 0.02 A/mm in 4th order and a bandpass of 0.14 A ({approx}13 km/s) at 3131 A in 4th order with 100 {mu}m entrance slit. The instrument temperature of the spectrometer is 15 eV. Light from the output of an image intensifier in the spectrometer focal plane is coupled to a high-speed CMOS camera. The system can accommodate up to 20 spatial points recorded at 0.5 ms time resolution. During helicity injection, stochastic magnetic fields keep T{sub e} low ({approx}100 eV) and thus low ionization impurities penetrate to the core. Under these conditions, high core ion temperatures are measured (T{sub i} Almost-Equal-To 1.2 keV, T{sub e} Almost-Equal-To 0.1 keV) using spectral lines from carbon III, nitrogen III, and boron IV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact multichannel spectrometer for Thomson scattering

The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗