Design and photoemission studies of a high-gradient X-band photogun operating in the short-pulse regime
Not Available
Engineering topics
Publications and source records attributed to Wisniewski, Eric.
Not Available
Next-generation accelerator concepts, which hinge on the precise shaping of beam distributions, demand equally precise diagnostic methods capable of reconstructing beam distributions within six-dimensional position-momentum spaces. However, the characterization of intricate features within six-dimensional beam distributions using current diagnostic techniques necessitates a substantial number of measurements, using many hours of valuable beam time. Novel phase space reconstruction techniques are needed to reduce the number of measurements required to reconstruct detailed, high-dimensional beam features in order to resolve complex beam phenomena and as a feedback in precision beam shaping applications. In this study, we present a novel approach to reconstructing detailed six-dimensional phase space distributions from experimental measurements using generative machine learning and differentiable beam dynamics simulations. We demonstrate that this approach can be used to resolve six-dimensional phase space distributions from scratch, using basic beam manipulations and as few as 20 two-dimensional measurements of the beam profile. We also demonstrate an application of the reconstruction method in an experimental setting at the Argonne Wakefield Accelerator, where it is able to reconstruct the beam distribution and accurately predict previously unseen measurements 75× faster than previous methods.
Beams with cross-plane coupling or extreme asymmetries between the two transverse phase spaces are often encountered in particle accelerators. Flat beams with large transverse-emittance ratios are critical for future linear colliders. Similarly, magnetized beams with significant cross-plane coupling are expected to enhance the performance of electron cooling in hadron beams. Preparing these beams requires precise control and characterization of the four-dimensional transverse phase space. In this study, we employ generative phase-space reconstruction techniques to rapidly characterize magnetized and flat-beam phase-space distributions using a conventional quadrupole-scan method. The reconstruction technique is experimentally demonstrated on an electron beam produced at the Argonne Wakefield Accelerator and successfully benchmarked against conventional diagnostics techniques. Specifically, we show that predicted beam parameters from the reconstructed phase-space distributions (e.g., as magnetization and flat-beam emittances) are in excellent agreement with those measured from the conventional diagnostic methods. Published by the American Physical Society 2024
A new regime in radiofrequency (rf) breakdown, named the breakdown insensitive acceleration regime (BIAR), was observed in an 11.7 GHz metamaterial structure for wakefield acceleration driven by rf pulses with a duration of a few nanoseconds. In the BIAR, rf breakdown occurs without interrupting potential beam acceleration, resulting in greater resilience to breakdown. We have investigated the possibility that BIAR can support higher gradients by characterizing the breakdown in a high-power test. The peak gradient reached 190 MV / m when the structure was powered by 6 ns long rf pulses with 115 MW peak power. The short rf pulses were extracted from 65 MeV electron bunch trains with a total charge of up to 210 nC. This work has revealed the benefits of short-pulse acceleration by characterizing rf breakdown in the previously unexplored parameter space. Published by the American Physical Society 2024
Bright electron beams have played a critical role in many recent advances in accelerator technology. Producing bright beams via photo-emission is ultimately limited by the mean transverse energy (MTE), which is determined by the photocathode. This paper discusses the opportunity to generate bright electron beams using an upgraded version of the Argonne Wakefield Accelerator (AWA) photo-injector. The focus of this study is to examine the optimal configurations of the AWA photo-injector to produce 100 pC with a ∼100 nm transverse emittance (corresponding to a 5D brightness B5≥1015 A·m−2). The numerical optimization of the AWA photo-injector operating point, including realistic electromagnetic field maps, is presented for the different types of photocathodes under consideration.
Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.
Dielectric Wakefield Acceleration (DWA) is a promising technique for realizing the next generation of linear colliders. It provides access to significantly higher accelerating gradients than traditional radio-frequency cavities. One impediment to realizing a DWA-powered accelerator is the issue of the transverse stability of the beams within the dielectric structure due to short-range wakefields. These short-range wakefields have a tendency to induce a phenomenon known as single-bunch beam breakup, which acts as its name implies and destroys the relevant beam. We attempt to solve this issue by leveraging the quadrupole mode excited in a planar dielectric structure and then alternating the orientation of said structure to turn an unstable system into a stable one. We examine this issue computationally to determine the limits of stability and based on those simulations describe a future experimental realization of this strategy.
OPAL-FEL is a recently developed tool for the modeling of particle accelerators containing wigglers or undulators. It extends the well established 3D electrostatic particle-tracking code OPAL, by merging it with the finite-difference time-domain electromagnetic solver MITHRA. We present results of two benchmark cases where OPAL-FEL simulations are compared to experimental results. Both experiments concern electron beamlines where the longitudinal phase space is modulated with a short magnetic wiggler. Good agreement was found in both the space charge and radiation dominated regimes.
A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.
Abstract Particle accelerators are invaluable discovery engines in the chemical, biological and physical sciences. Characterization of the accelerated beam response to accelerator input parameters is often the first step when conducting accelerator-based experiments. Currently used techniques for characterization, such as grid-like parameter sampling scans, become impractical when extended to higher dimensional input spaces, when complicated measurement constraints are present, or prior information known about the beam response is scarce. Here in this work, we describe an adaptation of the popular Bayesian optimization algorithm, which enables a turn-key exploration of input parameter spaces. Our algorithm replaces the need for parameter scans while minimizing prior information needed about the measurement’s behavior and associated measurement constraints. We experimentally demonstrate that our algorithm autonomously conducts an adaptive, multi-parameter exploration of input parameter space, potentially orders of magnitude faster than conventional grid-like parameter scans, while making highly constrained, single-shot beam phase-space measurements and accounts for costs associated with changing input parameters. In addition to applications in accelerator-based scientific experiments, this algorithm addresses challenges shared by many scientific disciplines, and is thus applicable to autonomously conducting experiments over a broad range of research topics.
High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.
Quantum efficiency (QE), intrinsic emittance, and robustness are the three most important figures of merit for photocathodes, the first two determine the ultimate achievable brightness of an electron beam, and the third one directly correlates with the complications of a beamline design. Nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] materials are promising candidates for photocathode applications due to their remarkable electron emission performance as well as the moderate vacuum requirement. Two (N)UNCD photocathodes have been characterized in a realistic RF gun environment with the nicely balanced performance of all three figures of merit. In this work, the QE of the first (N)UNCD cathode (stored in air for two years before the test) was found to be 3.8 x 10 –4 using a 262 nm UV laser and a cathode surface field of 30MV/m. It was found that the QE of the second (N)UNCD sample (grown days before the test) was nearly the same and, therefore, demonstrates the exceptional environmental tolerance of the material. The intrinsic emittance of (N)UNCD was measured to be 1.00 μm/mm.
Diamond field-emitter arrays (DFEAs) are arrays of diamond pyramids with exquisitely sharp tips and micrometer-scale bases that produce high current densities. These arrays can be fabricated in arbitrary shapes, ranging from single tips to many millions of tips, so that they produce an inherently shaped electron beam. Each tip emits a modest current, but the large dense array can produce many Amps. We are investigating these cathodes for use in dielectric wakefield accelerators; however, they may also be applicable to vacuum microwave tubes. Recently, shaped beam production and transport have been demonstrated in the 1.3-GHz RF gun at the Argonne Cathode Test Stand at the Argonne National Laboratory. The charge was measured on a Faraday cup and the beam imaged on a YAG screen with peak electric field gradients on the cathode ranging from 12 to 35 MV/m. Three cathode geometries were tested: one 1-mm equilateral triangle with 7-mu m base pyramids and 10-mu m pitch, one 1-mm equilateral triangle with 10-mu m base and 25-mu m pitch, and one sparse 5 x 5 square array with 20-mu m base and 400-mu m pitch. The two triangular arrays emitted 35 nC in an RF macropulse at 35 MV/m and 13-nC charge at 27 MV/m, respectively, while the sparse array emitted 0.060-nC charge at 15 MV/m. This article presents the results of the triangular array experiments, including damage due to breakdown in the RF gun and initial models of tip-to-tip shielding.
Planar nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] has emerged as a unique field emission source attractive for accelerator applications because of its capability to generate a high charge beam and handle moderate vacuum conditions. Most importantly, (N)UNCD sources are simple to produce: Conventional high aspect ratio isolated emitters are not required to be formed on the surface, and the actual emitter surface roughness is on the order of only 10–100 nm. A careful reliability assessment of (N)UNCD is required before it may find routine application in accelerator systems. In the present study using an L-band normal conducting single-cell rf gun, a (N)UNCD cathode has been conditioned to ~ 42 MV / m in a well-controlled manner. It reached a maximum output charge of 15 nC corresponding to an average current of 6 mA during an emission period of 2.5 $μ$s . Imaging of the emission current revealed a large number of isolated emitters (density over 100/cm 2 ) distributed on the cathode, which is consistent with previous tests in dc environments. The performance metrics, the emission imaging, and the systematic study of emission properties during rf conditioning in a wide gradient range assert (N)UNCD as an enabling electron source for rf injector designs serving industrial and scientific applications. These studies also improve the fundamental knowledge of the practical conditioning procedure via a better understanding of the emission mechanisms.
Beams with large transverse emittance ratios (flat beams) have received renewed interest for their possible applications in future linear colliders and advanced accelerators. A flat beam can be produced by generating a magnetized beam and then repartitioning its emittance using three skew quadrupoles. In this paper, we report on the experimental generation of ~1nC flat beams at the Argonne WakefieldAccelerator (AWA). The emittance ratio of the flat beam is demonstrated to be continuously variable by adjusting the magnetic field on the cathode.
Undesirable electron field emission (also known as dark current) in high gradient rf photocathode guns deteriorates the quality of the photoemission current and limits the operational gradient. To improve the understanding of dark current emission, a high-resolution (~100 μm) dark current imaging experiment has been performed in an L-band photocathode gun operating at ~100 MV/m of surface gradient. Scattered strong emission areas with high current have been observed on the cathode. The field enhancement factor β of selected regions on the cathode has been measured. Finally, the postexaminations with scanning electron microscopy and white light interferometry reveal the origins of ~75% strong emission areas overlap with the spots where rf breakdown has occurred.
In photocathodes the achievable electron-beam parameters are controlled by the laser used to trigger the photoemission process. Non-ideal laser distribution hampers the final beam quality. Laser inhomogeneities, for instance, can be "amplified" by space-charge force and result in fragmented electron beams. To overcome this limitation laser shaping methods are routinely employed. In the present paper we demonstrate the use of simple microlens arrays to dramatically improve the transverse uniformity. We also show that this arrangement can be used to produce transversely-patterned electron beams. Our experiments are carried out at the Argonne Wakefield Accelerator facility.