Search NASA⌕ Search

Engineering topics

Wittwer, Felix

Publications and source records attributed to Wittwer, Felix.

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

ExaFEL: extreme-scale real-time data processing for X-ray free electron laser science

ExaFEL is an HPC-capable X-ray Free Electron Laser (XFEL) data analysis software suite for both Serial Femtosecond Crystallography (SFX) and Single Particle Imaging (SPI) developed in collaboration with the Linac Coherent Lightsource (LCLS), Lawrence Berkeley National Laboratory (LBNL) and Los Alamos National Laboratory. ExaFEL supports real-time data analysis via a cross-facility workflow spanning LCLS and HPC centers such as NERSC and OLCF. Our work therefore constitutes initial path-finding for the US Department of Energy's (DOE) Integrated Research Infrastructure (IRI) program. We present the ExaFEL team's 7 years of experience in developing real-time XFEL data analysis software for the DOE's exascale supercomputers. We present our experiences and lessons learned with the Perlmutter and Frontier supercomputers. Furthermore we outline essential data center services (and the implications for institutional policy) required for real-time data analysis. Finally we summarize our software and performance engineering approaches and our experiences with NERSC's Perlmutter and OLCF's Frontier systems. This work is intended to be a practical blueprint for similar efforts in integrating exascale compute resources into other cross-facility workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Accelerating x-ray tracing for exascale systems using Kokkos

The upcoming exascale computing systems Frontier and Aurora will draw much of their computing power from GPU accelerators. The hardware for these systems will be provided by AMD and Intel, respectively, each supporting their own GPU programming model. The challenge for applications that harness one of these exascale systems will be to avoid lock-in and to preserve performance portability. We report here on our results of using Kokkos to accelerate a real-world application on NERSC's Perlmutter Phase 1 (using NVIDIA A100 accelerators) and Crusher, the testbed system for OLCF's Frontier (using AMD MI250X). By porting to Kokkos, we successfully ran the same X-ray tracing code on both systems and achieved speed-ups between 13 % and 66 % compared to the original CUDA code. Finally, these results are a highly encouraging demonstration of using Kokkos to accelerate production science code.

97 MATHEMATICS AND COMPUTING↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

The nanoscale distribution of copper and its influence on charge collection in CdTe solar cells

For decades, Cu has been the primary dopant in CdTe photovoltaic absorbers. Typically, Cu acceptor concentrations in these devices are on the order of 1 1014 cm-3, which has made it notoriously difficult to directly correlate nanoscale Cu distributions to the local charge transport properties of these devices. To measure and correlate these properties, measurement techniques require high sensitivity to elemental concentration, large penetration depth, and operando compatibility. Techniques such as secondary-ion mass spectroscopy and X-ray energy dispersive spectroscopy are widely adopted to measure Cu concentrations, but they are limited by penetration depth, sensitivity, or spatial resolution. Additionally, they lack the operando capabilities required to correlate one-to-one Cu concentrations to electrical performance. In this work, correlative X-ray microscopy is used to investigate the spatial distribution of Cu and its impact on charge collection through the depth and breadth of CdTe photovoltaic devices. Plan-view, nanoscale X-ray fluorescence maps clearly demonstrate the spatial segregation of copper around regions thought to be CdTe grain boundaries. Complementary cross-section imaging unveils the transition of the maximum charge-collection efficiency from the ZnTe-CdTe interface to the CdS-CdTe interface as a function of Cu incorporation. The copper concentration through the depth of the CdTe layer is characterized by slow and fast diffusion components, and cross-section charge-transport modeling shows that the experimentally obtained charge collection can be explained by the modeled acceptor distribution through the depth of the CdTe layer.

14 SOLAR ENERGY↗

Nanofocusing with aberration-corrected rotationally parabolic refractive X-ray lenses

Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with σ¯ = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without prior lens characterization but simply based on the derived lens deformation. As a result, the performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Focusing hard x rays beyond the critical angle of total reflection by adiabatically focusing lenses

In response to the conjecture that the numerical aperture of x-ray optics is fundamentally limited by the critical angle of total reflection, the concept of adiabatically focusing refractive lenses was proposed to overcome this limit. Here, we present an experimental realization of these optics made of silicon and demonstrate that they indeed focus 20 keV x rays to a 18.4 nm focus with a numerical aperture of 1.73(9) × 10 –3 that clearly exceeds the critical angle of total reflection of 1.55 mrad.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perfect X-ray focusing via fitting corrective glasses to aberrated optics

Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today’s technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. As a result, this scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗