Search NASA⌕ Search

Engineering topics

Wollack, Edward J.

Publications and source records attributed to Wollack, Edward J..

At least 55 records · Page 3

Low-Loss Microstrip Transmission Line Fabricated with Improved Liftoff Process

The µ-Spec integrated spectrometer operating at ~500 GHz, employs thin film superconducting Nb microstrip transmission lines deposited directly on a thin (450 nm) single-crystal silicon dielectric. This single-crystal silicon layer is chosen as the dielectric layer due to its low intrinsic loss, with the goal of achieving both high- efficiency and precise phase control in a compact spectrometer architecture. To avoid roughening or etching through the thin single-crystal silicon dielectric a liftoff technique was developed for patterning these microstrip transmission lines and ground plane structures. This two- layer liftoff process was designed for use with sputter deposition and resulted in a US patent. Although this original technique provided precise control of linewidth, results of initial prototype spectrometer devices and separate diagnostic co-planer waveguide resonator devices showed that unexpected loss was being introduced due to the lift-off process. This extra loss was believed to be due to the “tails” (thin tapered regions) at the edge of the metal traces resulting from the sputtering process, as well as an amorphous oxide layer at the Nb-Si interface. We have since demonstrated an improved lift-off technique, which provides a clean metal-Si interface and removes the loss-inducing tails by a two-step selective etching method. This results in a decrease in microwave loss by more than an order of magnitude when measured in co-planar waveguide microwave resonator structures. We present these microwave test results and also SEM and TEM images of the microstrip interfaces and edge profiles before and after application of the improved process.

Hess, Larry A.↗

Fabrication of Phononic-Isolated Kinetic Inductance Detectors

Kinetic inductance detectors (KID) have received increased interest due to their relative ease of fabrication, low noise, and scalability to large format arrays required by next generation of astronomical telescopes. The development of KIDs has progressed rapidly, with very low noise equivalent power demonstrated by several groups and KIDs arrays implemented in several ground-based and air-borne instruments. In this paper, we describe a new fabrication process which consists of a membrane isolated KID incorporating a phononic bandgap structure tuned to block recombination phonons from escaping to the thermal bath. This architecture is designed to increase the quasi-particle lifetime and results in increased responsivity to signal photons and lower noise. These devices have been fabricated as lumped-element resonators with hafnium inductors and Nb capacitors on low stress silicon nitride and silicon-on-insulator membranes. We discuss the fabrication process, which uses a combination of sub-micron laser based direct write lithography and nanoscale electron beam lithography.

Denis, Kevin L.↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

Planar Via-Less Crossover Having Coplanar Waveguide Configurations and Stub Layers

A via-less crossover for use in broadband microwave/mm-wave circuitry, including: a dielectric substrate; a top layer disposed on one side of the substrate and including a microstrip line with an input and an output, two tapered sections placed around the microstrip line along a co-planar waveguide (CPW) central line, one microstrip portion having an input and which connects to one top layer, rectangular stub disposed adjacent to one of the tapered sections, and another microstrip portion having an output and which connects to another top layer, rectangular stub disposed adjacent to the other of the tapered sections; and a ground layer disposed on an opposite side of the substrate and including a bottom layer CPW central line situated in a central cutout and which connects between a bottom layer, rectangular stub on one side and a bottom layer, rectangular stub on the other side situated in ground cutouts, respectively.

U-Yen, Kongpop↗

Dielectric Properties of Conductively Loaded Polyimides in the Far Infrared

The dielectric properties of selected conductively-loaded polyimide samples are characterized in the microwave through far-infrared wavebands. These materials, belonging to the Vespel family, are more readily formed by direct machining than their ceramic-loaded epoxy counterparts and present an interesting solution for realizing absorptive optical control structures. Measurements spanning a spectral range from 1 to 600 cm(exp −1) (0.03–18 THz) were performed and used in parametrization of the media’s dielectric function at frequencies below ≈3 THz.

Helson, Kyle R.↗

Physics of the Cosmos (PCOS) Program Technology Development 2018

We present a final report on our program to raise the Technology Readiness Level (TRL) of enhanced charge‐coupled‐device (CCD) detectors capable of meeting the requirements of X‐ray grating spectrometers (XGS) and wide‐field X‐ray imaging instruments for small, medium, and large missions. Because they are made of silicon, all X‐ray CCDs require blocking filters to prevent corruption of the Xray signal by out‐of‐band, mainly optical and near‐infrared (near‐IR) radiation. Our primary objective is to demonstrate technology that can replace the fragile, extremely thin, free‐standing blocking filter that has been standard practice with a much more robust filter deposited directly on the detector surface. High‐performance, back‐illuminated CCDs have flown with free‐standing filters (e.g., one of our detectors on Suzaku), and other relatively low‐performance CCDs with directly deposited filters have flown (e.g., on the X‐ray Multi‐mirror Mission‐Newton, XMM‐Newton Reflection Grating Spectrometer, RGS). At the inception of our program, a high‐performance, back‐illuminated CCD with a directly deposited filter has not been demonstrated. Our effort will be the first to show such a filter can be deposited on an X‐ray CCD that meets the requirements of a variety of contemplated future instruments. Our principal results are as follows: i) we have demonstrated a process for direct deposition of aluminum optical blocking filters on back‐illuminated MIT Lincoln Laboratory CCDs. Filters ranging in thickness from 70 nm to 220 nm exhibit expected bulk visible‐band and X‐ray transmission properties except in a small number (affecting ≲ 1% of detector area) of isolated detector pixels ("pinholes"), which show higher‐than‐expected visible‐band transmission; ii) these filters produce no measurable degradation in soft‐X‐ray spectral resolution, demonstrating that direct filter deposition is compatible with the MIT Lincoln Laboratory back‐illumination process; iii) we have shown that under sufficiently intense visible and near‐IR illumination, out‐of‐band light can enter the detector through its sidewalls and mounting surfaces, compromising detector performance. This 'sidewall leakage' has been observed, for example, by a previous experiment on the International Space Station during its orbit‐day operations. We have developed effective countermeasures for this sidewall leakage; iv) we developed an exceptionally productive collaboration with the Regolith X‐ray Imaging Spectrometer (REXIS) team. REXIS is a student instrument now flying on the Origins Spectral Interpretation Resource Identification Security - Regolith Explorer (OSIRIS‐REx) mission. REXIS students participated in our filter development program, adopted our technology for their flight instrument, and raised the TRL of this technology beyond our initial goals. This Strategic Astrophysics Technology (SAT) project, a collaboration between the MKI and MIT Lincoln Laboratory, began July 1, 2012, and ended on June 30, 2018.

PCOS↗

Robust Waveguide Millimeter Wave Noise Source

Aspects of the present disclosure involve a system and method for generating noise waves at millimeter wave frequencies. A noise source generator is designed to be connected to a crystalline structure for efficient heat transfer and compatibility with millimeter wave receivers. The use of crystalline structure coupled to the noise source generator allows heat from a biasing device, such as a diode, to be carried away such that the diode is able to generate noise waves while being reversed biased without compromising the device. In another embodiment, the noise source generator includes the use of a backshort transmission line with vias that is connected to the biasing device for heat transfer from the biasing device to the backshort.

Ehsan, Negar↗

The Primordial Inflation Polarization Explorer (PIPER): Current Status and Performance of the First Flight

The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne instrument optimized to measure the polarization of the CMB at large angular scales. It will map 85% of the sky over a series of conventional balloon flights from the Northern and Southern hemispheres, measuring the B-mode polarization power spectrumover a range of multipoles from 2-300 covering both the reionization bump and the recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007. PIPER will observe in four frequency bands centered at 200, 270, 350, and 600 GHz to characterize dust foregrounds. The instrument has background-limited sensitivity provided by fully cryogenic (1.7 K) optics focusing the sky signal onto kilo-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 100 mK. Polarization sensitivity and systematiccontrol are provided by front-end Variable-delay Polarization Modulators (VPMs). PIPER had its engineering flight in October 2017 from Fort Sumner, New Mexico. This papers outlines the major components in the PIPER system discussing the conceptual design as well as specific choices made for PIPER. We also report on the results of the engineering flight, looking at the functionality of the payload systems, particularly VPM, as well as pointing out areas of improvement.

Pawlyk, Samuel↗

Aerogel Scattering Filters for Cosmic Microwave Background Observations

We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and sub-millimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultra-low-density (< 100 mg/cu cm) aerogel substrate provides an index of refraction as low as 1.05, removing the need for anti-reflection coatings and allowing for broadband operation from DC to above 1 THz. The size distribution of the scattering particles can be tuned to provide a variable cutoff frequency. Aerogel filters with embedded high-resistivity silicon powder are being produced at 40-cm diameter to enable large-aperture cryogenic receivers for cosmic microwave background polarimeters, which require large arrays of sub-Kelvin detectors in their search for the signature of an inflationary gravitational-wave background.

Essinger-Hileman, Thomas↗

SiAl Alloy Feedhorn Arrays: Material Properties, Feedhorn Design, and Astrophysical Applications

We present here a study of the use of the SiAl alloy CE7 for the packaging of silicon devices at cryogenic temperatures. We report on the development of baseplates and feedhorn arrays for millimeter wave bolometric detectors for astrophysics. Existing interfaces to such detectors are typically made either of metals, which are easy to machine but mismatched to the thermal contraction profile of Si devices, or of silicon, which avoids the mismatch but is difficult to directly machine. CE7 exhibits properties of both Si and Al, which makes it uniquely well suited for this application. We measure CE7 to a) superconduct below a critical transition temperature, T (sub c), 1.2 K, b) have a thermal contraction profile much closer to Si than metals, which enables simple mating, and c) have a low thermal conductivity which can be improved by Au-plating. Our investigations also demonstrate that CE7 can be machined well enough to fabricate small structures, such as #0-80 threaded holes, to tight tolerances (approximately 25 microns) in contrast with pure silicon and similar substrates. We have fabricated CE7 baseplates being deployed in the 93 gigahertz polarimetric focal planes used in the Cosmology Large Angular Scale Surveyor (CLASS). We also report on the development of smooth-walled feedhorn arrays made of CE7 that will be used in a focal plane of dichroic 150/220 gigahertz detectors for the CLASS High-Frequency camera.

Ali, Aamir M.↗

E-Beam Generated Plasma Etching for Developing High-Reflectance Mirrors for Far-Ultraviolet Astronomical Instrument Applications

Astronomical space telescopes to study astrophysical phenomena from the far-ultraviolet (FUV) to the near infrared (NIR) will require mirror coatings with high reflectance over this entire spectral region. While coatings for the optical and NIR part of the spectrum are fairly well developed with proven performance, the FUV presents significant challenges. The U.S. Naval Research Laboratory (NRL) has developed a processing system based on an electron beam-generated plasma that provides for controlled fluorination and/or etching of surfaces with near monolayer precision and minimal changes to surface morphology. In this paper, we report recent results of samples treated in the NRL Large Area Plasma Processing System (LAPPS) where restoration of the high intrinsic reflectance in the FUV spectral range have been observed of aluminum (Al) mirrors protected with a magnesium di-fluoride (MgF2) overcoat. This paper will also extend these studies to other Al mirrors protected with aluminum tri-fluoride (AlF3) in order to realize the high intrinsic reflectance Al down to FUV wavelengths (100−200 nm), while still maintaining the high reflectance in the optical and NIR spectral regions. Laboratory test data and optical diagnostic techniques used to verify surface scattering and durability of selected coatings will be presented. Finally, we will discuss the scalability of the LAPPS etching process in order to realize these high-reflectivity coatings on mirror segments as large as those proposed for the Large Ultraviolet, Optical, and Infrared (LUVOIR) astronomical telescope system (1+meter class).

LUVOIR↗

A Cryogenic Thermal Source for Detector Array Characterization

We describe the design, fabrication, and validation of a cryogenically compatible quasioptical thermal source for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire electron discharge machining process. The absorptive mixture is bonded to a copper backplate enabling thermalization of the entire structure and measurement of the source temperature. Measurements indicate that the reflectance of the source is less than 0.001 across a spectral band extending from 75 to 330 gigahertz.

Chuss, David T.↗

A Space-Based Observational Strategy for Characterizing the First Stars and Galaxies Using the Redshifted 21cm Global Spectrum

The redshifted 21 cm monopole is expected to be a powerful probe of the epoch of the first stars and galaxies(10 less than z less than 35). The global 21 cm signal is sensitive to the thermal and ionization state of hydrogen gas and thusprovides a tracer of sources of energetic photonsprimarily hot stars and accreting black holeswhich ionize andheat the high redshift intergalactic medium (IGM). This paper presents a strategy for observations of the globalspectrum with a realizable instrument placed in a low-altitude lunar orbit, performing night-time 40120 MHzspectral observations, while on the farside to avoid terrestrial radio frequency interference, ionospheric corruption,and solar radio emissions. The frequency structure, uniformity over large scales, and unpolarized state of theredshifted 21 cm spectrum are distinct from the spectrally featureless, spatially varying, and polarized emissionfrom the bright foregrounds. This allows a clean separation between the primordial signal and foregrounds. Forsignal extraction, we model the foreground, instrument, and 21 cm spectrum with eigenmodes calculated viaSingular Value Decomposition analyses. Using a Markov Chain Monte Carlo algorithm to explore the parameterspace defined by the coefficients associated with these modes, we illustrate how the spectrum can be measured andhow astrophysical parameters (e.g., IGM properties, first star characteristics) can be constrained in the presence offoregrounds using the Dark Ages Radio Explorer (DARE).

Burns, Jack O.↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

A Path to High Efficiency Optical Coupling for HIRMES

The high-resolution mid-infrared spectrometer (HIRMES) under development for SOFIA (Stratospheric Observatory for Infrared Astronomy) is an instrument operating in the 25-122 μm spectral range with a spectral resolution R= Δ ʎ /ʎ ~100,000 and has two absorber-coupled transition edge sensor (TES) bolometric detector focal planes. We have developed novel NbTiN low stress absorber coatings which have the required optical impedance across the HIRMES operating band. The low intrinsic stress of these coatings allow for a peak-to-valley corrugation amplitude < 5 μm of the 450 nm thick, 1.4 mm x 1.7 mm detector pixels. Furthermore, these coatings have a superconducting transition temperature ~ 10 K, which allows them to simultaneously serve as an absorber in the desired signal band and a rejection filter at long wavelengths. This attribute makes them especially attractive for ultrasensitive absorber-coupled bolometric detector applications, because it helps in controlling the optical loading from out-of band radiation. We also discuss a novel method for integrating a wedged reflective absorber-termination to the detector array.

bolometers↗

Characterization of Si-Membrane TES Bolometer Arrays for the HIRMES Instrument

The High Resolution Mid-Infrared Spectrometer (HIRMES) instrument will fly onboard NASA's airborne Stratospheric Observatory for Infrared Astronomy (SOFIA) in 2019. HIRMES will provide astronomers with a unique observing window (25 122 µm) for exploring the evolution of protoplanetary disks into young solar systems, and the composition of our Solar System. There are two focal plane detector arrays for the instrument: a high-resolution (/ = 100,000) 8x16 detector array with a target noise-equivalent power, NEP 3x10-18 W/Hz; and a low-resolution (/ = 2,000 19,000) 16x64 detector array with a target NEP 2x10-17 W/Hz. The detectors for both of these arrays are superconducting Mo/Au bilayer transition edge sensor (TES) bolometers on thin suspended single-crystal silicon membranes. Here we present our characterization results for the detectors in both arrays, including measurements of thermal conductance with comparison to phonon transport models, saturation power, noise, and array uniformity.

Instrumentation and Photography↗

Two-Season Atacama Cosmology Telescope Polarimeter Lensing Power Spectrum

We report a measurement of the power spectrum of cosmic microwave background (CMB) lensing from two seasons of Atacama Cosmology Telescope polarimeter (ACTPol) CMB data. The CMB lensing power spectrum is extracted from both temperature and polarization data using quadratic estimators. We obtain results that are consistent with the expectation from the best-fit Planck CDM model over a range of multipoles L 80-2100, with an amplitude of lensing A(sub lens) = 1.06 +/- 0.15 stat +/- 0.06 sys relative to Planck. Our measurement of the CMB lensing power spectrum gives sigma 8 omega m(sup 0.25) = 0.643 +/- 0.054; including baryon acoustic oscillation scale data, we constrain the amplitude of density fluctuations to be sigma 8 = 0.831 +/- 0.053. We also update constraints on the neutrino mass sum. We verify our lensing measurement with a number of null tests and systematic checks, finding no evidence of significant systematic errors. This measurement relies on a small fraction of the ACTPol data already taken; more precise lensing results can therefore be expected from the full ACTPol data set.

Shewin, Blake D.↗

The Atacama Cosmology Telescope: Two-Season ACTPol Spectra and Parameters

We present the temperature and polarization angular power spectra measuredby the Atacama Cosmology Telescope Polarimeter (ACTPol). We analyze night-time datacollected during 2013-14 using two detector arrays at 149 GHz, from 548 deg(exp. 2) of sky onthe celestial equator. We use these spectra, and the spectra measured with the MBAC camera on ACT from 2008-10, in combination with Planck and WMAP data to estimate cosmological parameters from the temperature, polarization, and temperature-polarization cross-correlations. We find the new ACTPol data to be consistent with the CDM model. The ACTPol temperature-polarization cross-spectrum now provides stronger constraints on multiple parameters than the ACTPol temperature spectrum, including the baryon density, the acoustic peak angular scale, and the derived Hubble constant. The new ACTPol dataprovide information on damping tail parameters. The joint uncertainty on the number of neutrino species and the primordial helium fraction is reduced by 20% when adding ACTPol to Planck temperature data alone.

Louis, Thibaut↗