Search NASA⌕ Search

Engineering topics

Wollack, Edward J.

Publications and source records attributed to Wollack, Edward J..

152 records · Page 9

A Quasioptical Vector Interferometer for Polarization Control

We present a mathematical description of a Quasioptical Vector Interferometer (QVI), a device that maps an input polarization state to an output polarization state by introducing a phase delay between two linear orthogonal components of the input polarization. The advantages of such a device over a spinning wave-plate modulator for measuring astronomical polarization in the far-infrared through millimeter are: 1. The use of small, linear motions eliminates the need for cryogenic rotational bearings, 2. The phase flexibility allows measurement of Stokes V as well as Q and U, and 3. The QVI allows for both multi-wavelength and broadband modulation. We suggest two implementations of this device as an astronomical polarization modulator. The first involves two such modulators placed in series. By adjusting the two phase delays, it is possible to use such a modulator to measure Stokes Q, U, and V for passbands that are not too large. Conversely, a single QVI may be used to measure Q and V independent of frequency. In this implementation, Stokes U must be measured by rotating the instrument. We conclude this paper by presenting initial laboratory results.

Chuss, David T.↗

Charge-Dissipative Electrical Cables

Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

Kolasinski, John R.↗

Silicon Hot-Electron Bolometers

We discuss a new type of direct detector, a silicon hot-electron bolometer, for measurements in the far-infrared and submillimeter spectral ranges. High performance bolometers can be made using the electron-phonon conductance in heavily doped silicon to provide thermal isolation from the cryogenic bath. Noise performance is expected to be near thermodynamic limits, allowing background limited performance for many far infrared and submillimeter photometric and spectroscopic applications.

Stevenson, Thomas R.↗

A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

Benford, Dominic↗

Cryogenetically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

An Anomalous External Force on the MAP Spacecraft

A common theme in discussions of the Microwave Anisotropy Probe (MAP) is the attainment of mission goals for minimal cost. One area of cost savings was a reduction in the fuel budget required. To reach orbit around the L2 notation point of the Earth-Sun system, the MAP spacecraft was guided very close to the Moon, allowing a gravity-assisted trajectory out to L2. In order to property time the lunar swing-by, MAP followed a trajectory of three-and-a-half highly elliptical phasing loops. At each perigee of this trajectory MAP executed a thruster maneuver to increase orbit velocity; maneuvers were required at one or both clothe first two perigees (called P1 and P2) and at the third and final perigee (P-final). The preference was for successful maneuvers at all three perigees because this scheme provided a small, additional fuel savings.

Starin, Scott R.↗

An Anomalous Force on the Map Spacecraft

The Microwave Anisotropy Probe (MAP) orbits the second Earth-Sun libration point (L2)-about 1.5 million kilometers outside Earth's orbit-mapping cosmic microwave background radiation. To achieve orbit near L2 on a small fuel budget, the MAP spacecraft needed to swing past the Moon for a gravity assist. Timing the lunar swing-by required MAP to travel in three high-eccentricity phasing loops with critical maneuvers at a minimum of two, but nominally all three, of the perigee passes. On the approach to the first perigee maneuver, MAP telemetry showed a considerable change in system angular momentum that threatened to cause on-board Failure Detection and Correction (FDC) to abort the critical maneuver. Fortunately, the system momentum did not reach the FDC limit; however, the MAP team did develop a contingency strategy should a stronger anomaly occur before or during subsequent perigee maneuvers, Simultaneously, members of the MAP team developed and tested various hypotheses for the cause of the anomalous force. The final hypothesis was that water was outgassing from the thermal blanketing and freezing to the cold side of the solar shield. As radiation from Earth warmed the cold side of the spacecraft, the uneven sublimation of frozen water created a torque on the spacecraft.

Starin, Scott R.↗

Cryogenically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗