Multi-Probe Radiography: For 2035 and Beyond

The Multi-Probe Radiography Project is investigating the use of multiple species of probe beams to provide more information from a radiography. Contextual radiographic, source, and measurements information is being provided through a series of four workshops at Los Alamos National Laboratory. The third workshop on Accelerator and Pulsed Power Technology is summarized in this report. The state of the large NNSA facilities such as Scorpius, DARHT, pRad, and Cygnus are presented. Future enhancements and innovative upgrades are also discussed.

43 PARTICLE ACCELERATORS↗

Mitigation and characterization of crosstalk between laser-driven radiography sources

Radiography with multiple probe species offers the potential to extract additional information about a given object as compared to radiography with a single probe species. Notably, the flexibility for high-power, short-pulse lasers to accelerate a variety of particle species makes laser-driven sources an attractive option to achieve multi-probe radiography. However, crosstalk produced by each of laser-driven source may be responsible for substantial backgrounds on detectors, becoming a significant barrier to achieving simultaneous radiography. In this work, we describe measurements of and mitigation strategies against crosstalk between laser-driven radiography sources in experiments at the OMEGA EP laser.

47 OTHER INSTRUMENTATION↗

Multi-Probe 24A: Post shot Data and Analysis

The Multi-Probe 24A experiments took place on the Omega EP laser in November 2023. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron ion beams from a range of film thicknesses, and x-ray sources from the established CPC+Ta wire targets. The backlighter was used for ion acceleration in the pitcher series, in which deuteron and proton beams characterized as a function of CD film thickness to develop a pitcher for a pitcher-catcher neutron radiographic source, while also characterizing electrons and x-rays emitted perpendicular to the target (i.e. Crosstalk for sidelighter-driven x-ray beams). The sidelighter was used for electron acceleration in the x-ray series, in which the electron acceleration and subsequent x-rays was characterized from the CPC+Ta wire targets and radiography was conducted with and without electro-magnetic electron defection. For the pitcher series, we found that at 500 J and 0.7 ps the 700-800 nm CD films yielded the greatest number and highest energy for both protons and deuterons. For the x-ray series, results demonstrated: a significant number of <100 keV x-rays are produced within the glue that fills the CPC cone, on-axis electron signal from the x-ray targets produce electrons resolvable up to ~10 MeV, and electron deflection (using MIFEDS) has a notable effect radiograph on noise reduction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust unfolding of MeV x-ray spectra from filter stack spectrometer data

Here, we present an inversion method capable of robustly unfolding MeV x-ray spectra from filter stack spectrometer (FSS) data without requiring an a priori specification of a spectral shape or arbitrary termination of the algorithm. Our inversion method is based upon the perturbative minimization (PM) algorithm, which has previously been shown to be capable of unfolding x-ray transmission data, albeit for a limited regime in which the x-ray mass attenuation coefficient of the filter material increases monotonically with x-ray energy. Our inversion method improves upon the PM algorithm through regular smoothing of the candidate spectrum and by adding stochasticity to the search. With these additions, the inversion method does not require a physics model for an initial guess, fitting, or user-selected termination of the search. Instead, the only assumption made by the inversion method is that the x-ray spectrum should be near a smooth curve. Testing with synthetic data shows that the inversion method can successfully recover the primary large-scale features of MeV x-ray spectra, including the number of x-rays in energy bins of several-MeV widths to within 10%. Fine-scale features, however, are more difficult to recover accurately. Examples of unfolding experimental FSS data obtained at the Texas Petawatt Laser Facility and the OMEGA EP laser facility are also presented.

47 OTHER INSTRUMENTATION↗

Diagnostics for Short-Pulse Radiography

The Multi-Probe project is developing radiographic techniques using probe beams generated by short-pulse lasers. Shortcomings in present detectors and future capabilities in new devices are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe 24A Pre-Shot report

The Multi-Probe Radiography campaign will field a full day of experiments at the Omega EP laser facility. The day consists of shots alternating between Omega EP’s two short-pulse laser beams. The Backlighter beam will generate proton and deuteron beams from 500-800nm CH/CD film targets, and the Sidelighter beam will accelerate electrons to generate x-rays from 0.5mm x 25-50µm Ø Ta wire targets attached to Compound Parabolic Concentrator (CPC) cones. The ion beams shots will optimize CD foil thickness (maximizing ion energy/yield) for the transparency regime for use as the pitcher in a pitcher catcher neutron-generation platform. Several shots will include a LiF catcher within the NTA and this feeds into future neutron radiography work. X-ray shots will be used to characterize the platform established in FY2020B via measurement of electron spectra with and without the Ta wire, and radiography will be conducted at varying laser energies. This will validate PIC electron acceleration modeling while also demonstrating potential for using the x-ray platform for imaging of thicker objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe 23A Pre-Shot report

The Multi-Probe Radiography campaign will field a full day of experiments at the Omega EP laser facility. The experiments will consist of shots that alternate between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The proton beam is intended to be used as a radiographic source, while the deuteron beam will be used as the pitcher in a pitcher-catcher neutron-generation concept. For the proton beam, our goal is to characterize the angular distribution and energy spectra of unwanted x-rays that are generated during proton acceleration and were found to be problematic for simultaneous radiography in MP-22A. As part of this primary goal, we will test whether an x-ray shield, XBLK, can be used to prevent these x-rays from impacting other x-ray diagnostics. For the deuteron beam, our primary goal is to characterize the energy spectra and beam profile of deuterons accelerated from CD foils and foams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Probe 23A: Post shot Data and Analysis

The Multi-Probe 23A experiments took place on the Omega EP laser in December 2022. The experiments consisted of shots alternating between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The backlighter was used in the pitcher series, in which deuteron beams were generated to develop a pitcher for a pitcher-catcher neutron radiographic source. The sidelighter was used in the shielding series, in which proton beams was generated, and a metal shield, XBLK, was used to mitigate crosstalk between the proton target and image plates located perpendicularly to the proton beam axis. For the pitcher series, we found that we were able to generate a deuteron beam with CD film, but not CD foam, targets. For the shielding series, we found that 6 mm Al vastly outperformed similar thicknesses of Cu and Ta at mitigating the crosstalk, suggesting that electrons, rather than x-rays, are the primary source of crosstalk.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Probe 22A: Post shot Data and Analysis

The Multi-Probe 22A experiments took place on the Omega EP laser in March 2022. The goal was to discover issues with simultaneous x-ray and proton radiography of static and dynamic test objects. The x-ray and proton probes were generated by short-pulse laser-matter interactions. Significant crosstalk between the proton beam and x-ray detector was observed. Several static radiographs were made, including a set of proton images made with different laser energies. No dynamic objects were radiographed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deciphering the influence of high-flux helium plasma exposure on tungsten nanostructure growth using real-time, in situ spectroscopic ellipsometry

In situ analysis of surfaces during high-flux plasma exposure represents a long-standing challenge in the study of plasma–material interactions. While post-mortem microscopy can provide a detailed picture of structural and compositional changes, in situ techniques can capture the dynamic evolution of the surface. In this study, we demonstrate how spectroscopic ellipsometry can be applied to the real-time characterization of W nanostructure (also known as “fuzz”) growth during exposure to low temperature, high-flux He plasmas. Strikingly, over a wide range of sample temperatures and helium fluences, the measured ellipsometric parameters (Ψ,Δ) collapse onto a single curve that can be directly correlated with surface morphologies characterized by ex situ helium ion microscopy. The initial variation in the (Ψ,Δ) parameters appears to be governed by small changes in surface roughness (<50 nm) produced by helium bubble nucleation and growth, followed by the emergence of 50 nm diameter W tendrils. This basic behavior appears to be reproducible over a wide parameter space, indicating that the spectroscopic ellipsometry may be of general practical use as a diagnostic to study surface morphologies produced by high-flux He implantation in refractory metals. An advantage of the methods outlined here is that they are applicable at low incident ion energies, even below the sputtering threshold. As an example of this application, we apply in situ ellipsometry to examine how W fuzz growth is affected both by varying ion energy and the temperature of the surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How oxygen passivates polycrystalline nickel surfaces

The passivation of polycrystalline nickel surfaces against hydrogen uptake by oxygen is investigated experimentally with low energy ion scattering (LEIS), direct recoil spectroscopy (DRS), and thermal desorption spectroscopy (TDS). These techniques are highly sensitive to surface hydrogen, allowing the change in hydrogen adsorption in response to varying amounts of oxygen exposure to be measured. The chemical composition of a nickel surface during a mixed oxygen and hydrogen exposure was characterized with LEIS and DRS, while the uptake and activation energies of hydrogen on a nickel surface with preadsorbed oxygen were quantified with TDS. By and large, these measurements of how the oxygen and hydrogen surface coverage varied in response to oxygen exposure were found to be consistent with predictions of a simple site-blocking model. This finding suggests that, despite the complexities that arise due to polycrystallinity, the oxygen-induced passivation of a polycrystalline nickel surface against hydrogen uptake can be approximated by a simple site-blocking model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗