Search NASASearch

Engineering topics

Wood, C.

Publications and source records attributed to Wood, C..

At least 19 records

Cryovolcanic Features on Titan's Surface as Revealed by the Cassini RADAR

The Cassini Titan Radar Mapper obtained Synthetic Aperture radar images of about 1.1% of Titan's surface during the spacecraft s first targeted fly-by on October 26, 2004 (referred to as the Ta fly-by). These images revealed that Titan is very complex geologically. Features identified include a possible volcanic dome or shield, craters that appear to be of volcanic origin, and extensive flows. We will discuss these features and others that will likely be revealed during Cassini s T3 Titan fly-by of February 15, 2005, during which a swath covering comparable amount of the surface will be obtained. Additional information is included in the original extended abstract.

Lopes, R. M.

Titan's Elusive Lakes? Properties and Context of Dark Spots in Cassini TA Radar Data

Titan's atmospheric methane abundance suggests the likelihood of a surface reservoir of methane and a surface sink for its photochemical products, which might also be predominantly liquid. Although large expanses of obvious hydrocarbon seas have not been unambiguously observed, a number of rather radar-dark spots up to approximately 30 km across are observed in the Synthetic Aperture Radar (SAR) data acquired during the Cassini TA encounter on October 26th 2004. Here we review the properties and setting of these dark spots to explore whether these may be hydrocarbon lakes.

Lorenz, R. D.

Accurate determination of specific heat at high temperatures using the flash diffusivity method

The flash diffusivity method of Parker et al. (1961) was used to measure accurately the specific heat of test samples simultaneously with thermal diffusivity, thus obtaining the thermal conductivity of these materials directly. The accuracy of data obtained on two types of materials (n-type silicon-germanium alloys and niobium), was + or - 3 percent. It is shown that the method is applicable up to at least 1300 K.

Vandersande, J. W.

Novel fabrication technique for improving the figure-of-merit of thermoelectric materials

Reduction of the thermal conductivity of thermoelectric materials in order to improve the figure of merit and, hence, the conversion efficiency is discussed. A novel fabrication technique that reduces the thermal conductivity without too adverse an effect on the electrical properties is reported. This is achieved by producing an oxygen-free, very-fine-grain SiGe alloy with very small (on the order of 50 A) precipitates.

Beaty, J. S.

Effect of Ga and P dopants on the thermoelectric properties of n-type SiGe

The purpose of this study was to hot-press improved n-type Si80Ge20/GaP samples directly (without any heat treatment) and to confirm that a Ga/P ratio less than one increases the solubility of P and, hence, improves the power factor and Z. One of the three samples (Ga/P = 0.43) had an improvement in Z of about 20 percent between 400 and 1000 C over that for standard SiGe. This demonstrates that improved samples can be pressed directly and that a Ga/P ratio less than one is necessary. The other two samples (Ga/P = 0.33 and 0.50) had Z's equal to or less than that of standard SiGe but had a lower hot-pressing temperature than the improved sample.

Draper, S. L.

Measurement of Seebeck coefficient using a large thermal gradient

The integral method of measuring the Seebeck voltage, V(T), has been applied to short rod-shaped samples. In the present method, one end of the sample is held at a fixed temperature and the other end is automatically varied through a temperature T range of interest, up to a maximum temperature of 1000 C. The Seebeck coefficient is then obtained from the slope of the V(T) vs T curve. The method offers simplicity of sample handling and minimal operator involvement.

Wood, C.

Materials for thermoelectric energy conversion

The field of thermoelectric energy conversion is reviewed from both a theoretical and an experimental standpoint. The basic theory is introduced and the thermodynamic and solid state views are compared. An overview of the development of thermoelectric materials is presented with particular emphasis being placed on the most recent developments in high-temperature semiconductors. A number of possible device applications are discussed and the successful use and suitability of these devices for space power is manifest.

Wood, C.

High temperature thermal conductivity measurements on lanthanum sulfides using the flash method

In the past, high temperature specific heat and hence thermal conductivity measurements, using the flash method have not been very accurate. This is due to the difficulty of exactly determining the amount of heat deposited on the front face of a sample during each flash. This problem has now been solved by sputtering a thin layer of graphite on the standard reference and test samples. Data taken shows that the amount of heat deposited can now be determined to within about 2 percent resulting in more accurate thermal conductivity data. The results of measurements on several lanthanum sulfides with stoichiometries between LaS(1.35) and LaS(1.48) are reported and show a minimum in the lattice thermal conductivity at a composition of around LaS(1.41). This is believed to be due to the scattering of low-frequency phonons by large defects, i.e., second phase material (beta-phase) and pores.

Vandersande, J. W.

High-Temperature Thermoelectric Energy Conversion

Theory of thermoelectric energy conversion at high temperatures and status of research on conversion materials reviewed in report. Shows highest values of thermoelectric figure of merit, Z, found in semiconductor materials. Semiconductors keep wide choice of elements and compounds. Electrical properties tailored to particular application by impurity doping and control of stoichiometry. Report develops definition of Z useful for comparing materials and uses it to evaluate potentials of different classes of materialsmetals, semiconductors, and insulators.

Wood, C.

Thermoelectric Properties of Lanthanum Sulfide

Report describes measurement of Seebeck coefficient, electrical resistivity, thermal conductivity, and Hall effect in gamma-phase lanthanum sulfide with composition of La3-x S4. Results of study, part of search for high-temperature thermoelectric energy-conversion materials, indicate this sulfide behaves like extrinsic semiconductor over temperature range of 300 to 1,400 K, with degenerate carrier concentration controlled by stoichiometric ratio of La to S.

Wood, C.

Thermoelectric properties of cerium monopnictides

Several cerium pnictides have been synthesized from the pure elements and hot pressed into test samples. Measurements of Seebeck coefficients and electrical resistivities were performed on these samples from room temperature to 1000 C. Cerium arsenide and cerium antimonide are n-type; cerium nitride changes from p-type to n-type conduction at 800 C. The materials are semimetals with resistivities below 1 mohm/cm. Cerium arsenide is the most favorable of the pnictides studied for high-temperature thermoelectric energy conversion, with an average power factor of 15 microW/cm K sq from 500 to 1000 C.

Danielson, L. R.

Electronic transport properties of hot-pressed B6Si

Measurements of the electrical conductivity, Seebeck coefficient and Hall mobility from -300 K to -1300 K have been carried out on multiphase hotpressed samples of the nominal composition B6Si. In all samples the conductivity and the p-type Seebeck coefficient both increase smoothly with increasing temperature. By themselves, these facts suggest small-polaronic hopping between inequivalent sites. The measured Hall mobilities are always low, but vary in sign. A possible explanation is offered for this anomalous behavior.

Wood, C.

Effect of the microstructure on the thermoelectric properties of polycrystalline lanthanum chalcogenides

Small amounts of second phase materials can have important effects on the thermoelectric properties of polycrystalline gamma-La(3-x)X4 (X-S, Te; X in the range of 0 to 1/3). Microscopic examination by SEM of hot pressed La(3-x)Te4 samples has revealed from 1-5 vol. pct of La2O2Te, an amount which is not detected by X-ray powder diffraction measurements. This amount of La2O2Te resulting from oxygen contamination can reduce the concentration of electrons by as much as 10 to 75 percent below the electron concentration calculated for single phase La(3-x)Te4 in the composition range of greatest interest. Small amounts of second phase materials can also lower the lattice thermal conductivity by scattering low frequency phonons. These results indicate that microstructural effects should be considered when electrical and thermal properties of polycrystalline materials are analyzed.

Lockwood, A.

Brush-Type Connectors for Thermoelectric Elements

Wire brushes used to connect positive and negative legs of semiconductor thermoelectric generators to power leads and heat sources and sinks. Brushes are flexible thermal and electrical conductors that readily accommodate expansion and contraction of legs with changing temperature. Thus, direct conductive coupling between heat source and sink allowed, in contrast to older and less efficient method of having to couple radiatively to accommodate thermal expansion.

Wood, C.

Seebeck Coefficient Measured With Differential Heat Pulses

Common experimental errors reduced because pulse technique suppresses drifts in thermoelectric measurements. Differential-heat-pulse apparatus measures Seebeck coefficient in semiconductors at temperatures up to 1,900 K. Sample heated to measuring temperature in furnace. Ends of sample then differentially heated a few degrees more by lamps. Differential temperature rise and consequent Seebeck voltage measured via thermocouple leads. Because pulse technique used, errors that often arise from long-term drifts in thermoelectric measurements suppressed. Apparatus works with temperature differences of only few degrees, further increasing accuracy of coefficients obtained.

Zoltan, L.

Measuring Seebeck Coefficients With Large Thermal Gradients

Apparatus takes measurements and analyzes data automatically. Cylindrical sample is pressed between heater and water-cooled baseplate. Thermocouples at opposite ends of sample provide both temperatures and Seeback voltages. Conveniently shaped samples used, and results calculated by microcomputer and printed out.

Wood, C.

Reduced-Stress Mounting for Thermocouples

Mounting accommodates widely different coefficients of thermal expansion. In new method, legs of thermocouple placed in separate n- and p-type arrays. Two arrays contact common heat pipe as source but have separate heatpipe sinks. Net expansion (or contraction) taken up by spring mounting on heat-pipe sinks.

Wood, C.