Search NASA⌕ Search

Engineering topics

Wood, F. M., Jr.

Publications and source records attributed to Wood, F. M., Jr..

Laser-induced fluorescence of green plants. III - LIF spectral signatures of five major plant types

A technique amenable to remote sensing use which utilizes laser-induced fluorescence (LIF) properties of plants has been successfully used in the laboratory to identify five major plant types. These included herbaceous dicots, herbaceous monocots, conifers, hardwoods, and algae. Each of these plant types exhibited a characteristic LIF spectra when excited by a pulsed N2 laser emitting at 337 nm. Although monocots and dicots possess common fluorescence maxima at 440, 685, and 740 nm, they could be differentiated from one another by using the ratio of the square of the fluorescence intensity at 440 nm to the nonsquared intensity at 685 nm, i.e., (440)-squared/685. In all cases, monocots yielded a significantly higher ratio. Conifers have fluorescence maxima at 440, 525, and 740 nm but none at 685 nm. Hardwoods exhibited fluorescence at 440, 525, 685, and 740 nm. Algae had very low fluorescence at 440 nm, no fluorescence at 525 nm, and fluorescence maxima at 685 and 740 nm. For algae, the ratio of the fluorescence intensity at 685 nm to that at 740 nm was much greater than that for monocots, dicots, and hardwoods. The potential use of the LIF technique for individual species identification is suggested.

Chappelle, E. W.↗

Laser-induced fluorescence of green plants. I - A technique for the remote detection of plant stress and species differentiation

The laser-induced fluorescence (LIF) of green plants was evaluated as a means of remotely detecting plant stress and determining plant type. Corn and soybeans were used as representatives of monocots and dicots, respectively, in these studies. The fluorescence spectra of several plant pigments was excited with a nitrogen laser emitting at 337 nm. Intact leaves from corn and soybeans also fluoresced using the nitrogen laser. The two plant species exhibited fluorescence spectra which had three maxima in common at 440, 690, and 740 nm. However, the relative intensities of these maxima were distinctly different for the two species. Soybeans had an additional slight maxima at 525 nm. Potassium deficiency in corn caused an increase in fluorescence at 690 and 740 nm. Simulated water stress in soybeans resulted in increased fluorescence at 440, 525, 690, and 740 nm. The inhibition of photosynthesis in soybeans by 3-(3-4-dichlorophenyl)-1-1-dimethyl urea (DCMU) gave incresed fluorescence primarily at 690 and 740 nm. Chlorosis as occurring in senescent soybean leaves caused a decrease in fluorescence at 690 and 740 nm. These studies indicate that LIF measurements of plants offer the potential for remotely detecting certain types of stress condition and also for differentiating plant species.

Chappelle, E. W.↗

Quantitative simultaneous multi-element microprobe analysis using combined wavelength and energy dispersive systems

A combined WDS-EDS system obviates the severe X-ray peak overlap problems encountered with Na, Mg, Al and Si common to pure EDS systems. By application of easily measured empirical correction factors for pulse pile-up and peak overlaps which are normally observed in the analysis of silicate minerals, the accuracy of analysis is comparable with that expected for WDS electron microprobe analyses. The continuum backgrounds are subtracted for the spectra by a spline fitting technique based on integrated intensities between the peaks. The preprocessed data are then reduced to chemical analyses by existing data reduction programs.

Walter, L. S.↗