Search NASA⌕ Search

Engineering topics

Wood, M.

Publications and source records attributed to Wood, M..

VTO FY23 Annual Progress Report on 3D Printing of All-Solid-State Lithium Batteries

All-solid-state lithium metal batteries (ASSLBs) have attracted attention due to their potential for mitigating safety issues and addressing energy density limitations of conventional lithium-ion batteries (LIBs). While solid state electrolytes (SSEs) with room-temperature ionic conductivities greater than that of their liquid electrolyte counterparts have been discovered, integration of the different solid components of ASSLBs is not trivial. Taking garnet Li 7 La 3 Zr 2 O 12 (LLZO) electrolyte as an example, problems for this SSE include brittleness, high temperature processing for densification, poor contact with electrodes, and lack of scalable manufacturing methods. These obstacles must be overcome before LLZO becomes commercially viable for ASSLB applications.

25 ENERGY STORAGE↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vehicle Technology Office Battery Project (FY22Q4 Quarterly Report)

The project has two primary objectives: (1) down select three-dimensional (3D) printing and post-processing approaches for solid-state electrolyte (SSE) / cathode integration, and (2) understand battery failure mechanisms via ex situ and in situ characterization.

25 ENERGY STORAGE↗

VTO_2021_APR_LLNL_Ye

Traditional batteries are composed of two-dimensional films that are stacked and/or rolled. Thin film batteries display high power density while their thick film counterparts show good energy density, but it has proven difficult to concurrently achieve both within these planar form factors. In addition, conventional Li-ion batteries based on liquid organic electrolytes or gel polymer electrolytes have raised severe safety concerns due to the intrinsic flammable properties of the organic electrolytes. They are also not ideal for the use of high energy density metallic lithium (Li) anodes due to Li dendrite growth, or sulfur cathodes due to shuttling effects that result in fast capacity fade. There is an urgent need to develop safe, high-performance solid-state batteries (SSBs) with advanced electrolyte and separator technologies. Although in recent years a series of superionic conductors have been developed for electrolytes and separators, their performance does not satisfy demanding criteria due to large impedance from poor solid electrolyte-electrode contact and questionable electrochemical and mechanical stability. Unlike the well-established roll-to-roll fabrication of conventional Li-ion batteries, the processing of SSBs is unique due to the brittleness of solid-state electrolytes (SSEs). The commercially available or lab-developed SSE discs are usually very thick (hundreds of micrometers to millimeters) to overcome their brittle nature, which unfortunately increases the cell impedance and accounts for the majority of the overall cell weight and volume, leading to dramatically decreased power and energy densities. In this project, we will investigate 3D printing techniques to overcome safety, fabrication, mechanical, and electrochemical issues in SSBs. 3D printing builds complex structures in a layer-by-layer fashion, which allows rapid production of hierarchical architectures, gradient and multi-material structures, and multi-component assemblies. 3D printing is an emerging area that could fundamentally transform energy storage devices. For example, 3D printing can produce batteries with arbitrary form factors to fit a product’s specific volume requirements and can create interwoven electrode arrangements over a wide range of length scales to improve transport and increase power density for a given energy density. For SSBs, 3D printing may dramatically reduce the separator thickness from ~1 mm (by hydraulic pressing) to tens of micrometers or less. In addition, the interfacial contact area between the electrolyte and the electrode may be increased via 3D interdigitated designs. Hence, we expect a significant reduction of the overall cell impedance and enhancement of both energy and power densities of SSBs by harnessing an array of 3D printing technologies being developed at Lawrence Livermore National Laboratory (LLNL).

25 ENERGY STORAGE↗

Precision measurement of the neutral pion lifetime

The explicit breaking of the axial symmetry by quantum fluctuations gives rise to the so-called axial anomaly. This phenomenon is solely responsible for the decay of the neutral pion π0 into two photons (γγ), leading to its unusually short lifetime. Here, we precisely measured the decay width Γ of the π 0 → γγ process. The differential cross sections for π0 photoproduction at forward angles were measured on two targets, carbon-12 and silicon-28, yielding Γ(π 0 → γγ)=7.798±0.056(stat.)±0.109(syst.) eV, where stat. denotes the statistical uncertainty and syst. the systematic uncertainty. We combined the results of this and an earlier experiment to generate a weighted average of Γ(π 0 → γγ)=7.802±0.052(stat.)±0.105(syst.) eV. Our final result has a total uncertainty of 1.50% and confirms the prediction based on the chiral anomaly in quantum chromodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of remote reflectin spectroscopy to monitor plant health

Remote non-contact reflection spectroscopy is examined as a method for detecting stress in Controlled Ecological Life Support System (CELSS) type crops. Lettuce (Latuca Sativa L. cv. Waldmans Green) and wheat (Triticum Aestivum L. cv. Yecora Rojo) were grown hydroponically. Copper and zinc treatments provided toxic conditions. Nitrogen, phosphorous, and potassium treatments were used for deficiency conditions. Water stress was also induced in test plants. Reflectance spectra were obtained in the visible and near infrared (400nm to 2600nm) wavebands. Numerous effects of stress conditions can be observed in the collected spectra and this technique appears to have promise as a remote monitor of plant health, but significant research remains to be conducted to realize the promise.

Woodhouse, R.↗

Response to graded Lower Body Negative Pressure (LBNP) after space flight

The effects of space flight on orthostatic function were studied. LBNP tests (0 to -60 mmHg) were administered to 7 crew members preflight and 2 to 6 hrs after 6 to 9 day shuttle missions. Cardiac stroke volumes were obtained each minute by echo Doppler. Orthostatic responses are given. The data suggest a decline in postflight orthostatic function, as assessed by LBNP, due to reduced cardiac filling despite potentiated heart rate and vasoconstrictor reflex responses in most crew members.

Fortney, S.↗

Investigations of the mechanisms by which lower body negative pressure (LBNP) improves orthostatic responses

Saline ingestion during LBNP is a counter measure proposed to improve orthostatic function during space flight. To understand the mechanism(s) responsible for this effect, body fluid, endocrine, and orthostatic responses (graded LBNP tests) were measured during bed rest (BR) and after 2 hr and 4 hr LBNP/saline treatments (-30 mm Hg and 1 liter of isotonic saline). PV (from I-125 and hematocrit measurements) decreased during BR but was restored to the pre-bed rest level (3157 +/- 161 ml) 20 hrs after both 2 hr (3109 +/- 146 ml) and 4 hr (3144 +/- 173 ml) LBNP. The heart rate response to graded LBNP tests was significantly improved after the 4 hr, but not after the 2 hr treatment. These results suggest PV expansion may be responsible for some improvement in orthostatic responses, but other mechanisms also must contribute.

Fortney, S. M.↗