Search NASA⌕ Search

Engineering topics

Woods, Jason

Publications and source records attributed to Woods, Jason.

At least 19 records

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

Thermal battery cost scaling analysis: minimizing the cost per kW h

Thermal and cost-scaling analyses provide the tools to optimize the geometry of thermal batteries based on cost. Figures-of-merit comprised of storage material properties are derived as the quantities that should be maximized when different components dominate cost.

25 ENERGY STORAGE↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Finned-tube-integrated modular thermal storage systems for HVAC load modulation in buildings

While there is considerable focus on latent-based thermal energy storage (TES) systems, the low thermal conductivity of phase change materials (PCMs) remains a critical concern. Many approaches to enhance PCM conductivity either require complicated synthesis processes or are cost prohibitive. In this study, we investigate finned-tube modular TES systems, which are simple in design, easy to manufacture, and cost-effective due to their standard materials and components. The study includes detailed modeling and experimentation of two devices containing similar amounts of PCM but different fin spacings. The study reveals that having more fins does not necessarily increase the TES thermal performance because the reduction in the PCM volume fraction can reduce the TES volumetric and specific energy densities. We find that larger fin spacings provide a higher specific energy for lower C rates (<1C), while smaller fin spacings provide a higher specific energy for higher C rates (>1C).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EnergyPlus™ v.23.2.0 2023 [SWR-17-23]

EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption and water use in buildings. This is the EnergyPlus Development Repository. The Department of Energy maintains a public website for EnergyPlus where you can find much more information about the program. https://energyplus.net/ For detailed developer information, consult the wiki. https://github.com/NREL/EnergyPlus/wiki Many users (and developers) of EnergyPlus are active on Unmet Hours, so that's a great place to start if you have a question about EnergyPlus or building simulation. https://unmethours.com/questions/ For more in-depth, developer-driven support, please utilize the EnergyPlus Helpdesk. https://energyplushelp.freshdesk.com/support/home

Woods, Jason↗

The impact of non-ideal phase change properties on phase change thermal energy storage device performance

Phase change materials have been known to improve the performance of energy storage devices by shifting or reducing thermal/electrical loads. While an ideal phase change material is one that undergoes a sharp, reversible phase transition, real phase change materials do not exhibit this behavior and often have one or more non-idealities – glide, hysteresis, supercooling – associated with them. Experimental and modeling techniques to characterize these non-ideal properties are reasonably well understood, however, their impact on the performance of a thermal energy storage system is not fully understood. Herein, we analyze the performance of a heat exchanger with a phase change material as a function of the different non-idealities, for a heating and a cooling application. We focus on the impact of these non-ideal behaviors on different modes of operation of the thermal energy storage device, which will serve as a useful guide to researchers on the relative importance of the non-ideal properties, along with the necessary accuracy required during an experimental characterization.

25 ENERGY STORAGE↗

Engineered Polymer Architectures for Thermo–Responsive Desiccants in Dehumidification Applications

Humidity control is relevant to many processes in buildings and manufacturing and is responsible for over 600 million tons of CO 2 annually. As such, desiccants that can efficiently remove moisture from air can greatly reduce emissions. A new class of desiccant materials, thermo–responsive desiccants, has been of increased interest in the literature. These materials are generally based on thermo–responsive polymers and exhibit a temperature–dependent isotherm, an attribute that is small in traditional desiccants. In this work, seven key parameters needed to create an effective thermo–responsive polymer desiccant are identified using a combination of modeling and experimental data. Further, it is found that more thermo–responsiveness is not necessarily better for energy efficiency, and that an optimal, “medium” value is desired. Additionally, polymer composition and architecture play key roles in adjusting the seven key parameters. Finally, based on findings from both modeling and experimental work, guidelines on synthesizing future thermo–responsive polymer desiccants are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Phase Change Composite Thermal Energy Storage Using the Thermal Ragone Framework

The thermal Ragone framework can be applied to the design of thermal energy storage heat exchangers to identifying relationships between their power requirements and energy capabilities. This presentation focuses on the design of planar thermal energy storage heat exchangers with phase change materials and thermal conductivity additives. Finite-difference models were used to optimize thermal storage heat exchanger designs focusing on key design parameters of conductivity additive volume fraction, spacing between tubes, and the phase transition temperatures. Design trends were developed for optimal designs based on varying thermal power requirements. To aid in future device design, models of reduced complexity were developed with the ability to predict optimal designs with computational speeds up to 5,000 times faster than finite-difference models.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

Tube-in-tube ionic liquid heat exchanger employing a selectively permeable tube

A tube-in-tube heat exchanger utilizes a selectively permeable tube having a selective permeable layer to allow the refrigerant to transfer into an ionic liquid to generate heating or cooling. The ionic liquid then provides heating or cooling to a heat transfer fluid through a non-permeable layer or tube. The system may be configured as a shell and tube design, with the third fluid free to flow on the outside of the shell, or as a shell and tube-in-tube, with a central tube containing a first liquid, a second tube containing a second liquid, and an outer shell containing the third liquid. The selectively permeable tube may include an anion or cation selectively permeable layer and this layer may be supported by a support layer or tube.

Bahar, Bamdad↗

Analysis of Photovoltaic Energy: CRADA Number CRD-21-17862 (Cooperative Research and Development Final Report)

For this project, NREL will work with the Participant to model phase change material performance, model photovoltaic thermodynamics performance, and predict photovoltaic module durability based on environmental conditions to help develop optimized photovoltaic roofing designs. This project will develop thermodynamic models of integrated photovoltaic roofing with phase change materials. These models will be used to optimize the materials and design selections based on reducing photovoltaic operating temperatures while balancing cost effective integration of phase change materials.

14 SOLAR ENERGY↗

Measuring the maximum capacity and thermal resistances in phase-change thermal storage devices

Thermal energy storage can increase the efficiency of the electric grid by adding flexibility to thermal systems. The value of thermal storage is a function of its energy and power density, which are driven by the capacity and thermal resistances in the storage device. Measuring these properties in-situ at the device level is an important step to understanding the performance and improving the design of thermal storage systems. Here, we present methods to measure the total capacity and thermal resistances in heat exchangers with integrated phase change materials. These methods are demonstrated on two thermal storage devices - a 570-kWh ice-based storage tank and a 0.35-kWh graphite-tetradecane composite device. The results show how thermal resistances evolve with the state of charge and discharge rate in these devices and quantify the impact of applied pressure on the contact resistance in composite phase change material heat exchangers. The proposed method allows for easy comparison between different systems and provides information on the thermal bottlenecks limiting performance. Ultimately, these measurements will allow designers to make robust, high-performance thermal storage devices for next-generation thermal systems.

25 ENERGY STORAGE↗

Processing Compressed Expanded Natural Graphite for Phase Change Material Composites

Phase change materials (PCMs) are used in various thermal energy storage applications but are limited by their low thermal conductivity. One method to increase conductivity involves impregnating organic PCMs into highly porous conductive matrix materials. Of these materials, compressed expanded natural graphite (CENG) matrices have received the most attention. Despite this attention, the effect that CENG processing has on PCM saturation and overall matrix thermal conductivity has not been fully investigated. Therefore, the effect of the heat treatment process used to expand intercalated graphite flakes is evaluated here. Higher heat treatment temperatures yielded higher saturation rates and overall saturation at similar matrix porosities. For example, increasing temperature from 300 °C to 700 °C resulted in approximately 60%-70% increase in pore saturation after 100 minutes of soaking. The exposure time to heat treatment had less of an effect on PCM saturation. The exposure time had negligible effect above 30 min and above 500 °C heating temperatures. However, because the expanded graphite was found to oxidize around 700 °C, the use of longer exposure time in manufacturing applications can be beneficial if a shortened impregnation time is needed. Heat treatment conditions did not impact thermal conductivity. The composite latent heat of fusion was also reduced approximately proportionally to the PCM mass fraction. A local maximum in axial thermal conductivity was observed at around 83% porosity, which is similar to previous studies. The observed conductivity at this maximum was a factor of 81 times greater than the conductivity of the PCM.

36 MATERIALS SCIENCE↗

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Experimental screening of salt hydrates for thermochemical energy storage for building heating application

The selection of a suitable salt hydrate for use in a thermochemical energy storage system is challenging. In this work, the most promising salts to store intermediate heat energy were selected and tested. The criteria set are; volumetric energy density of >500 kWh m-3 with a dehydration temperature of <100 degrees C, material cost of <3.5 USD kg-1 (<15 USD kWh-1), melting does not occur during dehydration and safety. Based on that, the salt hydrates SrCl 2 , MgSO 4 , Na 3 PO 4 , MgCl 2 and SrBr 2 were selected and tested experimentally. A constant temperature and humidity chamber was used to measure moisture sorption of different salts. The hydration is investigated under the conditions of 20 degrees C and 20, 30, 40, 60 and 80% RH, while dehydration is investigated under the conditions of 70, 100 and 140 degrees C using an oven. These dehydration temperatures of <100 degrees C are suitable for solar application whereas the dehydration temperature of 140 degrees C is suitable for waste heat. Furthermore, the salts are cycled over 30 times under the hydration conditions of 20 degrees C, 60% RH with a dehydration temperature of 100 degrees C. From these results, it is concluded that SrCl 2 and SrBr 2 are the most promising salts. This study outlines both the advantages and disadvantages of each salt and states the conditions they are most suitable for.

25 ENERGY STORAGE↗

Humidity’s impact on greenhouse gas emissions from air conditioning

We report that the increasing need to cool the air in our built environment is both a cause and an effect of climate change. Air conditioning accounts for a large portion of global greenhouse gas emissions today, which we estimate at 3.9%; however, the role that humidity plays in these emissions is often overlooked. Here, we show that the emissions associated with reducing air humidity (i.e., removing water vapor from air) are larger than emissions associated with reducing air temperature (i.e., cooling air). We calculate these emissions for today and 2050 and show how dramatically humidity-related emissions will increase with rising cooling demand around the world. We also calculate the minimum separation energy for removing water vapor from air and find that this is at least an order of magnitude less than the processes used today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗