Search NASA⌕ Search

Engineering topics

Woods, Mike

Publications and source records attributed to Woods, Mike.

SLAC All Access: Laser Labs

From supermarket checkouts to video game consoles, lasers are ubiquitous in our lives. Here at SLAC, high-power lasers are critical to the cutting-edge research conducted at the laboratory. But, despite what you might imagine, SLAC's research lasers bear little resemblance to the blasters and phasers of science fiction. In this edition of All Access we put on our safety goggles for a peek at what goes on inside some of SLAC's many laser labs. LCLS staff scientist Mike Minitti and SLAC laser safety officer Mike Woods detail how these lasers are used to study the behavior of subatomic particles, broaden our understanding of cosmic rays and even unlock the mysteries of photosynthesis.

47 OTHER INSTRUMENTATION↗

Polarimetery for SuperB

We provide an overview description of a Compton polarimeter for measuring electron beam polarization near the IR in the Low Energy Ring of SuperB. The polarimeter is designed to achieve 1.0% accuracy. A scheme for measuring the electron beam polarization at SuperB near the IR has been described. The Compton polarimeter has been designed to fit into the existing lattice of the SuperB ring and results in a Compton IP measuring the polarization located where the beam is almost longitudinal with opposite helicity to that at the IR. The polarization at the IR is expected to be determined with an accuracy of {approx}1% from the measurement at the Compton IP provided the beam direction at the electron-positron interaction region and the Compton IP are well known and the beam energy is measured to better than 20 MeV. Detailed detector studies are needed to study resolution and acceptance effects on detector analyzing powers, and to determine sensitivity to beam and machine parameters.

43 PARTICLE ACCELERATORS↗

The National Dissemination of International Measurements

The paper presents the most significant actions which a primary Radionuclide Metrology Laboratory must accomplish, in order to disseminate the international equivalence to the entire national traceability chain: absolute standardization methods and demonstration of international equivalence, construction and calibration of a consistent set of secondary standardization equipment, preparation of radioactive standards. Delivery of radioactive standards to the end users and carrying out metrological services. Organization of national proficiency tests with the users. International validation of secondary standards by proficiency tests and establishment of a Quality System Assurance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard

The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee.According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures.When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results).Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results.Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine-Detector Interface Issues for the ILCPolarimeters

This note examines several Machine-Detector Interface (MDI) issues for the Compton polarimeters in the Beam Delivery System of the International Linear Collider (ILC), including (1) alignment tolerances, (2) impact of crossing angle and IR magnets on spin alignment, (3) Z-pole operation, and (4) costs and conventional facilities.

43 PARTICLE ACCELERATORS↗