Search NASA⌕ Search

Engineering topics

Woods, P. T.

Publications and source records attributed to Woods, P. T..

Column measurements of stratospheric trace species over Are, Sweden in the winter of 1991-1992

Total vertical column amounts of stratospheric HCl, HF, ClONO2 and HNO3 are reported from high resolution infrared solar absorption spectra taken during the European Arctic Stratospheric Ozone Experiment (EASOE) in the winter of 1991-1992. These ground based measurements were made near Are in North Sweden (63.4 deg N, 13.1 deg E) at an altitude of 800 m using a Fourier transform spectrometer and tunable diode laser heterodyne spectrometer. On 9th January 1992 the HCl vertical column dropped to 1.2 x 10(exp 15) molecules/sq cm from a November average of 3.6 x 10(exp 15) molecules/sq cm. The HCl drop occurred at a time when Are was below the polar vortex and the lower stratospheric ClO column above Are was elevated to approximately 2 x 10(exp 15) molecules/sq cm as measured by the Microwave Limb Sounder experiment on the Upper Atmosphere Research Satellite. These measurements indicate conversion of lower stratospheric chlorine from reservoir to chemically active forms.

Bell, W.↗

The determination of HNO3 column amounts from tunable diode laser heterodyne spectrometer spectra taken at Jungfruajoch, Switzerland

In May of 1991 a tunable diode laser heterodyne spectrometer built by the National Physical Laboratory was operated at the International Scientific Station of the Jungfraujoch (46.5 deg N, 8.0 deg E, altitude 3.56 km). Nitric acid spectra in the region of 868 wavenumbers were recorded at sunset and sunrise on two separate days at a resolution of 0.0013 wavenumbers with a signal-to-noise ratio of approximately 130:1. A vertical column amount of HNO3 of 1.61 x 10(exp 16) molecules/sq cm was determined using an atmospheric transmission model developed at the University of Denver. The mean of a number of mid-latitude, northern hemisphere profiles was used as the initial profile for the inversion. A comparison of different initial profiles provides information on the sensitivity of the retrieved column amount of 1.61 x 10(exp 16) molecules/sq cm lies within the range of values published in the World Meteorological Organization Report no. 16 (1986), but is considerably larger than the value of (0.99 - 1.29) x 10(exp 16) reported by Rinsland et al. (1991) for June during the period 1986 to 1990.

Fogal, P. F.↗

Measurements of fugitive hydrocarbon emissions with a tunable infrared DIAL

A tunable infrared differential absorption lidar (DIAL) system has been designed and developed at the National Physics Lab (NPL) which is capable of making measurements throughout the spectral region 3.0 to 4.2 micro-m. It is ideally suited to measuring a range of organic and inorganic species including methane, propane, and butane. The system also has an ultraviolet channel that is capable of making simultaneous measurements of aromatic hydrocarbons such as Toluene and benzene. This paper describes the source and detection system, together with some measurements of fugitive hydrocarbon emissions performed at various petrochemical plants.

Milton, M. J. T.↗

The Balloon Intercomparison Campaigns - An introduction and overview

The Balloon Intercomparison Campaigns of 1982 and 1983 involved a comparison of measurements by 21 instruments from seven countries, assembled on four gondolas, assigned to collect data on the vertical profiles of HCl, HNO3, NO2, NO, O3, and many other stratospheric constituents. Most of these sensors supplied data on more than two constituents. This paper describes the instruments and the constituents measured by each of the sensor and the parameters of each balloon flight, together with some results.

Watson, R. T.↗

Assesment of dial data collection and analysis techniques

The key issues in all areas of Differential Absorption Lidar (DIAL) data collection and analysis techniques were examined. This included consideration of the practical and theoretical limitations of DIAL and the range of possible DIAL measurements.

Browell, E. V.↗

Atmospheric contributions to the column variance in direct-detection dial

One of the most important parameters of a Differential Absorption Lidar (DIAL) system is the delay time between the on and off resonant pulses. It is important that this delay time is sufficiently small to ensure that the atmosphere is effectively frozen between the pulses. Therefore, most Dial systems were designed with two lasers firing alternately less than 1 msec apart. Despite the importance of this parameter in the design of DIAL systems and its contribution to the overall error of a column measurement, very little is known about the size of the error for the case of a direct-detection system using atmospheric backscatter. The ultraviolet DIAL system uses two independent YAG/dye lasers and is therefore suitable for measuring the effects of different pulse delays on the variance of column measurements for a variety of atmospheric conditions. A set of DIAL returns were acquired with the two lasers tuned to the same wavelength and with a range of pulse delay times between 250 microseconds and several minutes. This data set was recorded in full on a computer and was used both to test different averaging techniques and also to evaluate atmospheric contributions to DIAL columns.

Milton, M. J. T.↗