A soft x-ray transmission grating imaging-spectrometer for the National Ignition Facility
A soft x-ray transmission grating spectrometer has been designed for use on high energy-density physics experiments at the National Ignition Facility (NIF); coupled to one of the NIF gated x-ray detectors it records 16 time-gated spectra between 250 and 1000 eV with 100 ps temporal resolution. The trade-off between spectral and spatial resolution leads to an optimized design for measurement of emission around the peak of a 100-300 eV blackbody spectrum. Performance qualification results from the NIF, the Trident Laser Facility and vacuum ultraviolet beamline at the National Synchrotron Light Source, evidence a <100 {mu}m spatial resolution in combination with a source-size limited spectral resolution that is <10 eV at photon energies of 300 eV.
Inertial and magnetic fusion concepts in high energy density plasma physics at LANL
Abstract Not Provided
Ion focusing experiments using cusped hemi targets and 75 MeV protons from the high-contrast LANL trident laser
Abstract Not Provided