Search NASA⌕ Search

Engineering topics

Worley, Christopher G

Publications and source records attributed to Worley, Christopher G.

Application of Micro-XRF for Nuclear Materials Characterization and Problem Solving

Micro-X-ray fluorescence (MXRF) used for >> 20 years To date MXRF has been underutilized for nuclear materials (NM) spatially-resolved elemental characterization. Scanning electron microscopy (SEM) with EDX much more common for NM characterization at a micro scale. But MXRF fills gap for larger 10's microns to cm{sup 2} scales. Will present four interesting NM applications using MXRF. Demonstrated unique value of MXRF for various plutonium applications. Although SEM has much higher resolution, MXRF clearly better for these larger scale samples (especially non-conducting samples). MXRF useful to quickly identify insoluble particles in Pu/Np oxide. MXRF vital to locating HEPA filter Pu particles over cm{sup 2} areas which were then extracted for SEM morphology and particle size distribution analysis. MXRF perfect for surface swipes which are far too large for practical SEM imaging, and loose residue would contaminate SEM vacuum chamber. MXRF imaging of ER Plutonium metal warrants further studies to explore metal elemental heterogeneity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Waste reduction process improvements in the analysis of plutonium by x-ray fluorescence: results from multiple data sets

To minimize waste, improve process safety, and minimize costs, modifications were implemented to a method for quantifying gallium in plutonium metal using wavelength dispersive X-ray fluorescence. These changes included reducing sample sizes, reducing ion exchange process volumes, using cheaper reagent grade acids, eliminating the use of HF acid, and using more robust containment film for sample analysis. Relative precision and accuracy achieved from analyzing multiple aliquots from a single parent sample were {approx}0.2% and {approx}0.1% respectively. The same precision was obtained from analyzing a total of four parent materials, and the average relative accuracy from all the samples was 0.4%, which is within programmatic uncertainty requirements.

36 MATERIALS SCIENCE↗

Analysis of nuclear materials by energy dispersive x-ray fluorescence and spectral effects of alpha decay

Energy dispersive X-ray fluorescence (EDXRF) spectra collected from alpha emitters are complicated by artifacts inherent to the alpha decay process, particularly when using portable instruments. For example, {sup 239}Pu EDXRF spectra exhibit a prominent uranium L X-ray emission peak series due to sample alpha decay rather than source-induced X-ray fluorescence. A portable EDXRF instrument was used to collect spectra from plutonium, americium, and a Pu-contaminated steel sample. The plutonium sample was also analyzed by wavelength dispersive XRF to demonstrate spectral differences observed when using these very different instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Waste reduction and process improvements in the analysis of plutonium by x-ray fluorescence

Significant modifications were made to a sample preparation process for quantifying gallium in plutonium metal by wavelength dispersive X-ray fluorescence. These changes were made to minimize waste and improve process safety and efficiency. Sample sizes were reduced, cheaper sample preparation acids were used, and safety improvements were implemented. Using this modified process, results from analyzing a batch oftest samples indicated that relative precision and accuracy were {approx}0.2% and {approx}0.1% respectively, which is comparable to that obtained using the older, established sample preparation method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radioactive sample effects on EDXRF spectra

Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (a heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗