Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARAty: an architecture for reusable robotic software

In this article, we will present an overview of the Coupled Layered Architecture for Robotic Autonomy. CLARAty develops a framework for generic and reusable robotic components that can be adapted to a number of heterogeneous robot platforms.

robotic↗

Determination of Lubricants on Ball Bearings by FT-IR using an Integrating Sphere

The lifetime determination of space lubricants is done at our facility by accelerated testing. Several micrograms of lubricant are deposited on the surface of a ball by syringing tens of micro liters of dilute lubricant solution. The solvent evaporates and the mass of lubricant is determined by twenty weighings near the balance reliability limit. This process is timely but does not produce a good correlation between the mass of lubricant and the volume of solution applied, as would be expected. The amount of lubricant deposited on a ball can be determined directly by Fourier Transform - Infrared Spectroscopy using an integrating sphere. In this paper, we discuss reasons for choosing this methodology, optimization of quantification conditions and potential applications for the technique. The volume of lubricant solution applied to the ball gives better correlation to the IR intensity than does the weight.

Street, K. W.↗

The double oval UV auroral distribution. 2: The most poleward arc system and the dynamics of the magnetotail

The poleward arc system of a double oval distribution is shown to activate at the end of the optical expansion phase signifying the beginning of substorm recovery. The velocity dispersed ion signature (VDIS) can exist coincident with this discrete aurora developing on the most poleward oval. Although the VDIS is usually associated with ion beams in the plasma sheet boundary layer, it is demonstrated that the ionospheric signature is not beamlike but distributed in pitch angle. At the time when the double oval begins to form, the magnetic field in the magnetotail lobe becomes less flared and can show Pc 5 period oscillations. Similar pulsations also exist in the ionosphere associated with the most poleward oval and with stationary surge formation. Theoretical considerations link this phenomenon with a wave source tailward of x(sub GSE) = -30R(sub E) and fast mode evanescent waves propagating earthward in the tail lobe region. In this case the magnetotail appears to act like a waveguide and the plasma sheet boundary layer as a resonance region. This implies that the coupling of this fast mode waves is with the plasma sheet boundary layer and not with dipolar like field lines. The implications of this for the reconnection model of substorms are discussed.

Elphinstone, R. D.↗