Search NASA⌕ Search

Engineering topics

Wright, C.

Publications and source records attributed to Wright, C..

Sequential Probability Ratio Test for Collision Avoidance Maneuver Decisions Based on a Bank of Norm-Inequality-Constrained Epoch-State Filters

Sequential probability ratio tests explicitly allow decision makers to incorporate false alarm and missed detection risks, and are potentially less sensitive to modeling errors than a procedure that relies solely on a probability of collision threshold. Recent work on constrained Kalman filtering has suggested an approach to formulating such a test for collision avoidance maneuver decisions: a filter bank with two norm-inequality-constrained epoch-state extended Kalman filters. One filter models 1he null hypothesis 1ha1 the miss distance is inside the combined hard body radius at the predicted time of closest approach, and one filter models the alternative hypothesis. The epoch-state filter developed for this method explicitly accounts for any process noise present in the system. The method appears to work well using a realistic example based on an upcoming highly-elliptical orbit formation flying mission.

Carpenter, J. R.↗

Advanced Free Flight Planner and Dispatcher's Workstation: Preliminary Design Specification

The National Aeronautics and Space Administration (NASA) has implemented the Advanced Air Transportation Technology (AATT) program to investigate future improvements to the national and international air traffic management systems. This research, as part of the AATT program, developed preliminary design requirements for an advanced Airline Operations Control (AOC) dispatcher's workstation, with emphasis on flight planning. This design will support the implementation of an experimental workstation in NASA laboratories that would emulate AOC dispatch operations. The work developed an airline flight plan data base and specified requirements for: a computer tool for generation and evaluation of free flight, user preferred trajectories (UPT); the kernel of an advanced flight planning system to be incorporated into the UPT-generation tool; and an AOC workstation to house the UPT-generation tool and to provide a real-time testing environment. A prototype for the advanced flight plan optimization kernel was developed and demonstrated. The flight planner uses dynamic programming to search a four-dimensional wind and temperature grid to identify the optimal route, altitude and speed for successive segments of a flight. An iterative process is employed in which a series of trajectories are successively refined until the LTPT is identified. The flight planner is designed to function in the current operational environment as well as in free flight. The free flight environment would enable greater flexibility in UPT selection based on alleviation of current procedural constraints. The prototype also takes advantage of advanced computer processing capabilities to implement more powerful optimization routines than would be possible with older computer systems.

Wilson, J.↗

Analysis of myosin heavy chain mRNA expression by RT-PCR

An assay was developed for rapid and sensitive analysis of myosin heavy chain (MHC) mRNA expression in rodent skeletal muscle. Only 2 microg of total RNA were necessary for the simultaneous analysis of relative mRNA expression of six different MHC genes. We designed synthetic DNA fragments as internal standards, which contained the relevant primer sequences for the adult MHC mRNAs type I, IIa, IIx, IIb as well as the embryonic and neonatal MHC mRNAs. A known amount of the synthetic fragment was added to each polymerase chain reaction (PCR) and yielded a product of different size than the amplified MHC mRNA fragment. The ratio of amplified MHC fragment to synthetic fragment allowed us to calculate percentages of the gene expression of the different MHC genes in a given muscle sample. Comparison with the traditional Northern blot analysis demonstrated that our reverse transcriptase-PCR-based assay was reliable, fast, and quantitative over a wide range of relative MHC mRNA expression in a spectrum of adult and neonatal rat skeletal muscles. Furthermore, the high sensitivity of the assay made it very useful when only small quantities of tissue were available. Statistical analysis of the signals for each MHC isoform across the analyzed samples showed a highly significant correlation between the PCR and the Northern signals as Pearson correlation coefficients ranged between 0.77 and 0.96 (P < 0.005). This assay has potential use in analyzing small muscle samples such as biopsies and samples from pre- and/or neonatal stages of development.

Non-NASA Center↗

An infrared study of the remarkable dusty M star HR 3126

HR 3126 is a unique M giant star embedded in the bipolar reflection nebula IC 2220. In this paper we present new photometric and spectroscopic observations of HR 3126 and combine them with existing data from the literature in an extensive reappraisal of the star's properties at infrared wavelengths. The spectral energy distribution is consistent with an optical classification of M0-3 II with infrared excess. The dust shell cannot be fitted by a single-temperature blackbody: at least three components are required, with temperatures in the range 35-1300 K. On the basis of spectroscopy at 1-4 and 7-25 microns, combined with an assessment of various color-color diagrams, we are able to reject the hypothesis that HR 3126 is carbon-rich. Weak silicate emission features are detected at 10 and 19 microns, and a previous report of silicon carbide emission at 11.2 microns is not substantiated. It seems likely that HR 2136 is in a phase of advanced and rapid postmain-sequence evolution, possibly beginning its ascent of the asymptotic giant branch.

Chiar, J. E.↗

Interstellar ultraviolet absorption lines and galactic X-ray sources

X-ray photoionization can create zones of highly ionized trace elements in the interstellar gas around a galactic X-ray source. Ultraviolet absorption lines due to the resulting ionic column densities may be observable and may provide information on the environment and age of the X-ray source. The calculated column densities are sensitive to the rates of charge-exchange reactions.

Mccray, R.↗