Publications and source records attributed to Wright, Robert E..

Boundary-layer transition detection with infrared imaging emphasizing cryogenic applications

This paper reviews the technique of boundary-layer transition detection using infrared (IR) imaging, emphasizing cryogenic wind-tunnel testing. With the exception of the low-temperature effects on the IR radiation, the discussion is relevant to conventional wind-tunnel and flight testing as well. At low temperatures, IR imaging encounters a reduction in the radiated energy throughout the IR spectrum, combined with a shift to longer wavelengths of the bulk of the radiation. This radiation behavior affects the minimum resolvable temperature difference (MRTD) of the IR imaging system because of its fixed wave band sensitivity. In the absence of commercial long wavelength IR imaging systems, operating at wavelengths longer than 13 micron, some measures can be taken to alleviate the problem caused by the MRTD limitation. The thermal signature of transition can be enhanced by allowing a small and controlled temperature increase of the wind-tunnel flow that induces a transient heat transfer to the model. This action temporarily reveals the model area under the turbulent regime through its higher heating rate compared with the laminar regime. The contrast between the areas exposed to the two regimes can be enhanced by subtraction of thermograms (the equilibrium thermogram from the transient thermogram). Further visual improvement can be obtained through shade stretching or binary shading.

Gartenberg, Ehud↗

Transition detection studies in the cryogenic environment

Boundary-layer transition detection studies were carried out in the 0.3 Meter Transonic Cryogenic Tunnel on a supercritical airfoil, using an infrared imaging system. The purpose of the experiments was to determine the extent of the temperature range in which commercially available IR systems can detect transition in cryogenic environment. The experiment was designed to take advantage of a combination of factors including the wind tunnel operation mode, the model construction materials and the IR system image processing options. During the initial phases of the study, the IR based findings were confirmed by measurements done with a micro-thin hot-film system. Ultimately, free and forced transition could be detected down to 170 K.

Gartenberg, Ehud↗

Annealing Increases Stability Of Iridium Thermocouples

Metallurgical studies carried out on samples of iridium versus iridium/40-percent rhodium thermocouples in condition received from manufacturer. Metallurgical studies included x-ray, macroscopic, resistance, and metallographic studies. Revealed large amount of internal stress caused by cold-working during manufacturing, and large number of segregations and inhomogeneities. Samples annealed in furnace at temperatures from 1,000 to 2,000 degree C for intervals up to 1 h to study effects of heat treatment. Wire annealed by this procedure found to be ductile.

Germain, Edward F.↗

A preliminary study of factors affecting the calibration stability of the iridium versus iridium-40 percent rhodium thermocouple

An iridium versus iridium-40% rhodium thermocouple was studied. Problems associated with the use of this thermocouple for high temperature applications (up to 2000 C) were investigated. The metallurgical studies included X-ray, macroscopic, resistance, and metallographic studies. The thermocouples in the as-received condition from the manufacturer revealed large amounts of internal stress caused by cold working during manufacturing. The thermocouples also contained a large amount of inhomogeneities and segregations. No phase transformations were observed in the alloy up to 1100 C. It was found that annealing the thermocouple at 1800 C for two hours, and then at 1400 C for 2 to 3 hours yielded a fine grain structure, relieving some of the strains, and making the wire more ductile. It was also found that the above annealing procedure stabilized the thermal emf behavior of the thermocouple for application below 1800 C (an improvement from + or - 1% to + or - 0.02% within the range of the test parameters used).

Ahmed, Shaffiq↗