Wright, Robert J.

Publications and source records attributed to Wright, Robert J..

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

Apparatus and methods for location and sizing of trace gas sources

A system for detecting gas leaks and determining their location and size. A data gathering portion of the system utilizes a chosen geometrical configuration to collect path-integrated spectroscopic data over multiple paths around an area. A processing portion of the system applies a transport model together with meteorological data of the area to generate an influence function of possible leak locations on gas detector measurement paths, and applies an inversion model to the influence function, prior data, and the spectroscopic data to generate gas source size and location.

03 NATURAL GAS↗

Single-Blind Quantification of Natural Gas Leaks from 1 km Distance Using Frequency Combs

A new method is tested in a single-blind study for detection, attribution, and quantification of methane emissions from the natural gas supply chain, which contribute substantially to annual U.S. emissions. The monitoring approach couples atmospheric methane concentration measurements from an open-path dual frequency comb laser spectrometer with meteorological data in an inversion to characterize emissions. During single-blind testing, the spectrometer is placed >1 km from decommissioned natural gas equipment configured with intentional leaks of control- lable rate. Single, steady emissions ranging from 0 to 10.7 g min -1 (0-34.7 scfh) are detected, located, and quantified at three gas pads of varying size and complexity. The system detects 100% of leaks, including leaks as small as 0.96 g min -1 (3.1 scfh). It attributes leaks to the correct pad or equipment group (tank battery, separator battery, wellhead battery) 100% of the time and to the correct equipment (specific separator, tank, or wellhead) 67% of the time. All leaks are quantified to within 3.7 g min -1 (12 scfh); 94% are quantified to within 2.8 g min -1 (9 scfh). Finally, these tests are an important initial demonstration of the methodology’s viability for continuous monitoring of large regions, with extension to other trace gases and industries.

03 NATURAL GAS↗

Intercomparison of open-path trace gas measurements with two dual-frequency-comb spectrometers

Abstract. We present the first quantitative intercomparison between two open-path dual-comb spectroscopy (DCS) instruments which were operated across adjacent 2 km open-air paths over a 2-week period. We used DCS to measure the atmospheric absorption spectrum in the near infrared from 6023 to 6376 cm−1 (1568 to 1660 nm), corresponding to a 355 cm−1 bandwidth, at 0.0067 cm−1 sample spacing. The measured absorption spectra agree with each other to within 5 × 10−4 in absorbance without any external calibration of either instrument. The absorption spectra are fit to retrieve path-integrated concentrations for carbon dioxide (CO2), methane (CH4), water (H2O), and deuterated water (HDO). The retrieved dry mole fractions agree to 0.14 % (0.57 ppm) for CO2, 0.35 % (7 ppb) for CH4, and 0.40 % (36 ppm) for H2O at ∼ 30 s integration time over the 2-week measurement campaign, which included 24 °C outdoor temperature variations and periods of strong atmospheric turbulence. This agreement is at least an order of magnitude better than conventional active-source open-path instrument intercomparisons and is particularly relevant to future regional flux measurements as it allows accurate comparisons of open-path DCS data across locations and time. We additionally compare the open-path DCS retrievals to a World Meteorological Organization (WMO)-calibrated cavity ring-down point sensor located along the path with good agreement. Short-term and long-term differences between the open-path DCS and point sensor are attributed, respectively, to spatial sampling discrepancies and to inaccuracies in the current spectral database used to fit the DCS data. Finally, the 2-week measurement campaign yields diurnal cycles of CO2 and CH4 that are consistent with the presence of local sources of CO2 and absence of local sources of CH4.

Waxman, Eleanor M.↗