Engineering topics
Wright, Stuart
Publications and source records attributed to Wright, Stuart.
Characterizing defect structures in AM steel using direct electron detection EBSD
The mechanical properties of additive and traditionally manufactured alloys are largely dependent on the characteristics and distribution of dislocation cell networks that develop during the fabrication process. This work demonstrates the ability to quantitatively characterize these dislocation structures by high angular resolution electron backscatter diffraction analysis using a direct electron detector. The defect structures are characterized in terms of the geometrically necessary dislocation density and the associated Burgers vector and line direction. Furthermore, the results are discussed in terms of potential defect formation mechanisms.
HR-EBSD based Characterization of Dislocations in Additive Manufactured 316L Stainless Steel.
Abstract not provided.
Electron Backscatter Diffraction based Strain Analysis in the Scanning Electron Microscope.
Abstract not provided.
Resolving pseudosymmetry in γ-TiAl using cross-correlation electron backscatter diffraction with dynamically simulated reference patterns
Pseudosymmetry is a phenomenon that occurs when grains with different lattice parameters produce nearly identical diffraction patterns such that conventional electron backscatter diffraction (EBSD) techniques are unable to unambiguously differentiate the lattice orientations. This commonly occurs in materials with near-unity tetragonality, such as γ-TiAl. The current study uses cross-correlation EBSD to resolve pseudosymmetry in γ-TiAl. Three dynamically simulated reference patterns are generated for each point in the scan, one for each of the three potential pseudosymmetric orientations, which are subsequently correlated with the original pattern using six different methods in order to identify the correct orientation. The methods are first applied to a scan of dynamically simulated patterns, which is used to evaluate the sensitivity of the method to pattern resolution, pattern noise and pattern center error. It was determined that all six methods were 100% successful up to about 13 µm of pattern center error and pattern resolutions of about 80 × 80 pixels, and hence the methods were applied to an experimental sample of lamellar γ-TiAl. A hybrid combination of two of the methods was shown to successfully select the correct pseudosymmetry for about 96% of the points in the scan, improving upon the 70% accuracy of the Hough-based methods for the current study and 90% accuracy for previous studies resolving pseudosymmetry in lamellar γ-TiAl.