Search NASA⌕ Search

Engineering topics

Wu, G.

Publications and source records attributed to Wu, G..

At least 55 records · Page 3

Optimization of Clean Room Infrastructure and Procedure During LCLS-II Cryomodule Production at Fermilab

Optimization of Fermilab string assembly procedure and infrastructure has yielded a significant improvement of cryomodule particulate counts. Late production of LCLSII cryomodules were tested at CMTF at Fermilab and showed little to no x-ray up to administrative limit. The paper describes the field emission measurement instrumentation, field emission results of Fermilab’s LCLS-II cryomodules, clean room infrastructure upgrade and procedure optimization.

43 PARTICLE ACCELERATORS↗

Availability and Reliability analysis of Proton Improvement Plan-II Superconducting Radio Frequency Linear Accelerator

Proton Improvement Plan -II is high intensity and high energy proton accelerator which will be used to support neutrino program at Fermilab. Due to the requirement from experiments, this accelerator is designed to be a highly reliable and available system. In this paper, a reliability model has been created which depicts a complete accelerator system and supporting utilities. Reliability and Availability of the complete system are estimated. It has been shown that Availability and Reliability of the system can be increased significantly by introducing failure tolerance of the beamline elements in each accelerating section of superconducting linac.

43 PARTICLE ACCELERATORS↗

Magnetic Field Induced by Thermo Electric Current in LCLS-II Cryomodules

The Seebeck effect in metals plays an important role in cryomodule design and performance. As the cryomodule is cooled from room temperature to nominal cavity operating temperature of 2 K, components in the cryomodule experience varying temperatures. Some components such as power couplers have gradients from 300 K to 2 K. Such gradients and metallic paths form thermo-electric current loops that circulate through and around the niobium cavities. These currents will generate an additional magnetic field that could be trapped in the cavity wall during superconducting transition, as well as during cavity quench. This trapped field can degrade the cavity’s quality factor and increase heat load. A simple circuit model is proposed and compared to a calculated trapped field during LCLS-II cryomodule tests.

43 PARTICLE ACCELERATORS↗

Availability and Reliability Analysis of Proton Improvement Plan-II Superconducting Radio Frequency Linear Accelerator

Proton Improvement Plan -II is high intensity and high energy proton accelerator which will be used to support neutrino program at Fermilab. Due to the requirement from experiments, this accelerator is designed to be a highly reliable and available system. In this paper, a reliability model has been created which depicts a complete accelerator system and supporting utilities. Reliability and Availability of the complete system are estimated. It has been shown that Availability and Reliability of the system can be increased significantly by introducing failure tolerance of the beamline elements in each accelerating section of superconducting linac.

43 PARTICLE ACCELERATORS↗

Achievement of Ultra-High Quality Factor in Prototype Cryomodule for LCLS-II

Quality factor is a primary cost driver for high energy, continuous wave (CW) SRF linacs like the LCLS-II X-ray free electron laser currently under construction. Taking this into account, several innovations were introduced in the LCLS-II cryomodule design to push substantially beyond the previous state-of-the-art quality factor achieved in operation. This includes the first ever implementation of the nitrogen doping cavity treatment, the capability to provide high mass flow cooldown to improve expulsion of magnetic flux based on recent R&D, high performance magnetic shielding, and other critical subcomponents. To evaluate the implementation of these new cryomodule features, two prototype cryomodules were produced. In this paper, we present results from the prototype cryomodule assembled at Fermilab, which achieved unprecedented cavity quality factors of 3.0e10 at a nominal cryomodule voltage. We overview cavity performance, procedures to achieve ambient magnetic field < 5 mG at the cavity wall, and the successful demonstration of high mass flow cooldown in a cryomodule. The cavity performance under various cool down conditions are presented as well to show the impact of flux expulsion on Q0.

43 PARTICLE ACCELERATORS↗

Accelerating fields up to 49 MV/m in TESLA-shape superconducting RF niobium cavities via 75C vacuum bake

In this paper we present the discovery of a new surface treatment applied to superconducting radio frequency (SRF) niobium cavities, leading to unprecedented accelerating fields of 49 MV/m in TESLA-shaped cavities, in continuous wave (CW); the corresponding peak magnetic fields are the highest ever measured in CW, about 210 mT. For TESLA-shape cavities the maximum quench field ever achieved was ~45 MV/m - reached very rarely- with most typical values being below 40 MV/m. These values are reached for niobium surfaces treated with electropolishing followed by the so called mild bake, a 120C vacuum bake (for 48 hours for fine grain and 24 hours for large grain surfaces). We discover that the addition during the mild bake of a step at 75C for few hours, before the 120C, increases systematically the quench fields up to unprecedented values of 49 MV/m. The significance of the result lays not only in the relative improvement, but in the proof that niobium surfaces can sustain and exceed CW radio frequency magnetic fields much larger than Hc1, pointing to an extrinsic nature of the current field limitations, and therefore to the potential to reach accelerating fields well beyond the current state of the art.

43 PARTICLE ACCELERATORS↗

Effects of haemodilution on the optical properties of blood during coagulation studied by optical coherence tomography

We report an investigation of the effects of blood dilution with hypertonic (7.5 %) and normal (0.9 %) saline on its optical properties during coagulation in vitro using optical coherence tomography. The light penetration depth and attenuation coefficient are obtained from the dependences of reflectance on the depth. Normal whole blood has served as the control group. The average coagulation time is equal to 420±16,418±16 and 358±14 s with blood volume replacement of 2 %, 11 %, and 20 % by 0.9 % normal saline, respectively. With 2 %, 11% and 20% blood volume replacement with 7.5 % hypertonic saline, the average coagulation time is 422±17,1160±45 and 1730±69 s, respectively. For normal whole blood, the average coagulation time amounts to 425±19 s. it is shown that dilution with normal saline has a procoagulant effect when it replaces 20 % of blood volume, and hypertonic saline has an anticoagulant effect if it replaces 11 % or more of blood volume. It is concluded that optical coherence tomography is a potential technique to quantify and monitor the liquid – gel transition during the coagulation process of blood diluted by normal and hypertonic saline. (biophotonics)

60 APPLIED LIFE SCIENCES↗

Realizing the Potential of Micro-Phase Separated Block Copolymer Electrolytes: Ion Domain Connectivity Plays a Prominent Role in Ion Conduction

Block copolymer electrolytes (BCEs) offer the prospect of membranes with high ionic conductivity at lower ion-exchange capacities leading to membranes with robust mechanical properties. However, the microphase separated structure of such BCE membranes and its impact on membrane conductivity is poorly understood. Most studies assume that aggregated ionic domains in microphase separated BCEs, or random copolymers, is sufficient to foster facile ion conductivity. However, microphase separation alone cannot spur rapid ion conduction. In this paper, we demonstrate that ion domain connectivity greatly influences ion conductivity in BCEs. The results emphasize the importance of maximizing ion domain connectivity while minimizing terminal defects to realize BCEs with optimal ion transport properties.

36 MATERIALS SCIENCE↗

LCLS-II SRF Cavity Processing Protocol Development and Baseline Cavity Performance Demonstration

The ”Linac Coherent Light Source-II” Project will construct a 4 GeV CW superconducting RF linac in the first kilometer of the existing SLAC linac tunnel. The baseline design calls for 280 1.3 GHz nine-cell cavities with an average intrinsic quality factor Q0 of 2.7·1010 at 2K and 16 MV/m accelerating gradient. The LCLS-II high Q0 cavity treatment protocol utilizes the reduction in BCS surface resistance by nitrogen doping of the RF surface layer, which was discovered originally at FNAL. Cornell University, FNAL, and TJNAF conducted a joint high Q0 R&D program with the goal of (a) exploring the robustness of the N-doping technique and establishing the LCLS-II cavity high Q0 processing protocol suitable for production use, and (b) demonstrating that this process can reliably achieve LCLS-II cavity specification in a production acceptance testing setting. In this paper we describe the LCLS-II cavity protocol and analyze combined cavity performance data from both vertical and horizontal testing at the three partner labs, which clearly shows that LCLS-II specifications were met, and thus demonstrates readiness for LCLS-II cavity production.

Liepe, M.↗

Modeling Hierarchical Non-Precious Metal Catalyst Cathodes for PEFCs Using Multi-Scale X-ray CT Imaging

This paper reports the development of a model for simulating polymer electrolyte fuel cells (PEFCs) with non-precious metal catalyst (NPMC) cathodes. NPMCs present an opportunity to dramatically reduce the cost of PEFC electrodes by removing the costly Pt catalyst. To address the significant transport losses in thick NPMC cathodes (ca. >60 µm), we developed a hierarchical electrode model that resolves the unique structure of the NPMCs we studied. A unique feature of the approach is the integration of the model with morphology data extracted from nano-scale resolution X-ray computed tomography (nano-CT) imaging of the electrodes. A notable finding is the impact of the liquid water accumulation in the electrode and the significant performance improvement possible if electrode flooding is mitigated.

30 DIRECT ENERGY CONVERSION↗

Higher Order Modes Damping and Multipacting Analysis for the SPX Deflecting Cavity in APS Upgrade

A single-cell superconducting deflecting cavity operating at 2.815 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source (APS) upgrade. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. Using the electromagnetic simulation suite ACE3P, HOM damping will be calculated for the cavity including the full engineering design waveguide configurations and rf windows. Trapped modes in the bellows located in the beampipes connecting the cavities in a cryomodule will be computed and their effects on heating evaluated. Furthermore, multipacting activities at the end groups of the cavity will be identified to assess possible problems during high power processing.

Li, Z.↗

Mode Damping Measurement for the APS Deflecting Cavity

The Advanced Photon Source has considered using a deflecting-cavity-based scheme to produce short pulse xrays. A deflecting cavity design has been completed. To verify the simulation result on this cavity, a copper prototype of the design has been fabricated for bench measurement. In this paper, we report our measurement results on this cavity. All the cavity modes below 5 GHz were identified by comparing the field distributions with calculations along different beam paths. After adding the damper, the measured Qexts of those modes were consistent with calculated values, which demonstrated that the cavity damping scheme was sufficient to reduce the wake impedances well below the safety thresholds.

Nassiri, A.↗

Time-Resolved Temperature Mapping System for the APS Deflecting Cavity

Time-resolved temperature mapping of a superconducting cavity can give valuable information on the limiting process of the cavity performance. A fast temperature mapping system has been developed at Argonne National Laboratory (ANL) for a superconducting deflecting cavity test. The time resolution of the temperature mapping could be up to 50 us. Not only the spatial distribution of surface heating but also the thermodynamics can be recorded, which helps to understand the limitation mechanism. This new temperature mapping system has helped us to understand the rf performance limitations during the cavity vertical tests. Based on the findings from the temperature mapping, proper cavity treatment has been applied and the cavity performances have been improved.

Nassiri, A.↗