Search NASA⌕ Search

Engineering topics

Wu, Hong

Publications and source records attributed to Wu, Hong.

85 records · Page 5

Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in hybrid organic-inorganic film of chitosan/sol-gel/carbon nanotubes

A hybrid organic-inorganic nanocomposite film of chitosan/sol-gel/multi-walled carbon nanotubes was constructed for the immobilization of horseradish peroxidase (HRP). This film was characterized by scanning electron microscopy. Direct electron transfer (DET) and bioelectrocatalysis of HRP incorporated into the composite film were investigated. The results indicate that the film can provide a favorable microenvironment for HRP to perform DET on the surface of glassy carbon electrodes with a pair of quasi-reversible redox waves and to retain its bioelectrocatalytic activity toward hydrogen peroxide.

59 BASIC BIOLOGICAL SCIENCES↗

The Calculated and Measured Resistance for Splices between Conductors in a MICE Superconducting Coil

The resistance of superconducting joints within MICE coils is an important issue particularly for the coupling coils. The MICE tracker solenoids have only two superconducting joints in the three spectrometer set (end coil 1, the center coil and end coil 2). The AFC magnets may have only a single joint within the coil. The coupling coils may have as many as fifteen joints within the coil, due to relatively short piece lengths of the superconductor. LBNL and ICST looked at three types of coil joints. They are: (1) cold fusion butt joints, (2) side-by-side lap joints, and (3) up-down lap joints. A theoretical calculation of the joint resistance was done at LBNL and checked by ICST. After looking at the theoretical resistance of the three types of joints, it was decided that the cold welded butt joint was not an attractive alternative for joints within a MICE superconducting magnet coil. Side-by-side and up-down lap joints were fabricated at ICST using two types of soft solder between the conductors. These conductor joints were tested at LBNL at liquid helium temperatures over a range of magnetic fields. The joint resistance was compared with the theoretical calculations. Measurements of splice strength were also made at 300 K and 77 K.

42 ENGINEERING↗

EQCM Immunoassay for Phosphorylated Acetylcholinesterase as a Biomarker for Organophosphate Exposures Based on Selective Zirconia Adsorption and Enzyme-Catalytic Precipitation

A zirconia (ZrO2) adsorption-based immunoassay by electrochemical quartz crystal microbalance (EQCM) has been initially developed, aiming at the detection of phosphorylated acetylcholinesterase (AChE) as a potential biomarker for bio-monitoring exposures to organophosphate (OP) pesticides and chemical warfare agents. Hydroxyl-derivatized monolayer was preferably chosen to modify the crystal serving as the template for directing the electro-deposition of ZrO2 film with uniform nanostructures. The resulting ZrO2 film was utilized to selectively capture phosphorylated AChE from the sample media. Horseradish peroxidase (HRP)-labeled anti-AChE antibodies were further employed to recognize the captured phosphorylated protein. Enzyme-catalytic oxidation of the benzidine substrate resulted in the accumulation of insoluble product on the functionalized crystal. Ultrasensitive EQCM quantification by mass-amplified frequency responses as well as rapid qualification by visual color changes of product could be thus achieved. Moreover, 4-chloro-1-naphthol (CN) was comparably studied as an ideal chromogenic substrate for the enzyme-catalytic precipitation. Experimental results show that the developed EQCM technique can allow for the detection of phosphorylated AChE in human plasma. Such an EQCM immunosensing format opens a new door towards the development of simple, sensitive, and field-applicable biosensor for biologically monitoring low-level OP exposures.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Electrochemical Branched-DNA Assay for Polymerase Chain Reaction-Free Detection and Quantification of Oncogenes in Messenger RNA

We describe a novel electrochemical branched-DNA (bDNA) assay for polymerase chain reaction (PCR)-free detection and quantification of p185 BCR-ABL leukemia fusion transcript in the population of messenger RNA (mRNA) extracted from cell lines. The bDNA amplifier carrying high loading of alkaline phosphatase (ALP) tracers was used to amplify targets signal. The targets were captured on microplate well surfaces through cooperative sandwich hybridization prior to the labeling of bDNA. The activity of captured ALP was monitored by square-wave voltammetric (SWV) analysis of the electroactive enzymatic product in the presence of 1-napthyl-phosphate. The specificity and sensitivity of assay enabled direct detection of target transcript in as little as 4.6 ng mRNA without PCR amplification. In combination with the use of a well-quantified standard, the electrochemical bDNA assay was capable of direct use for a PCR-free quantitative analysis of target transcript in total mRNA population. The approach thus provides a simple, sensitive, accurate and quantitative tool alternate to the RQ-PCR for early disease diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Dye-Doped Silica Nanoparticle Labels/Protein Microarray for Detection of Protein Biomarkers

Biomarkers serve as indicators of biological and pathological processes, or physiological and pharmacological responses to a drug treatment. Interleukin-6 (IL-6), a biomarker with its important biological and pathological functions, has been studied for decades. Conventional fluorescence immunoassay has been widely used for analysis of biomakers like IL-6. However, single fluorophore labeling shows its limitations of low intensity and poor stability. We report a dye-encapsulated silica nanoparticle as a label, with the advantages of high fluorescence intensity, photostability, and biocompatibility, in conjunction with microarray technology for sensitive immunoassay of IL-6 on a microarray format. The tris (2,2’-bipyridyl)ruthenium (II)chloride hexahydrate (Rubpy) dye incorporated into silica nanoparticles using a simple one-step microemulsion synthesis step. The nanoparticles are uniform in size with a diameter of 50 nm. The microarray fluorescent immunoassay approach based on dye-doped silica nanoparticle labels has high sensitivity for practical applications with a limit of detection for IL-6 down to 0.1 ng mL-1. The calibration curve is linear over the range from 0.1 ng mL-1 to 10 ng mL-1. Furthermore, results illustrated that the assay is highly specific for IL-6 in the presence of range of cytokines or proteins. The RuDS dye-labeled nanoparticles in connection with protein microarrays show the promise for clinical diagnosis of biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoparticles for Enhanced Sensitivity in Electrochemical Immunoassays

In this manuscript, we report on electrochemical biosensors based on various nanoparticles (NPs) as labels for sensitive detection of protein biomarkers. We used silica nanoparticle as a carrier to loading a large amount of electroactive species such as poly(guanine) for sensitive immunoassay of tumor necrosis factor-alpha (TNF-a). We took the advantages of the unique hollow structure and reconstruction properties of apoferritin to prepare Cd3(PO4)2 nanoparticles as labels for sensitive assay of TNF-a. A novel immunochromatographic/electro-chemical biosensor based on quantum dots as labels has also been developed for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. These biosensors are quite sensitive with the detection limit at pM level and these approaches based on nanoparticle labels offer a new avenue for sensitive detection of protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Construction of Test Coils for the MICE Coupling Solenoid Magnet

The superconducting coupling solenoid to be applied in the Muon Ionization Cooling Experiment (MICE) is made from copper matrix Nb-Ti conductors with inner radius of 750 mm, length of 285 mm and thickness of 102.5 mm at room temperature. The magnetic field up to 2.6 T at the magnet centerline is to keep the muons within the MICE RF cavities. Its self inductance is around 592 H and its magnet stored energy is about 13 MJ at a full current of 210 A for the worst operation case of the MICE channel. The stress induced inside the coil during cool down and charging is relatively high. Two test coils are to build and test in order to validate the design method and develop the fabrication technique required for the coupling coil winding, one is 350 mm inner diameter and full length same as the coupling coil, and the other is one-quarter length and 1.5 m diameter. The 1.5 m diameter coil will be charged to strain conditions that are greater than would be encountered in the coupling coil. This paper presents detailed design of the test coils as well as developed winding skills. The analyses on stress in coil assemblies, AC loss, and quench process are carried out.

42 ENGINEERING↗

Quench Protection for the MICE Cooling Channel Coupling Magnet

This paper describes the passive quench protection system selected for the muon ionization cooling experiment (MICE) cooling channel coupling magnet. The MICE coupling magnet will employ two methods of quench protection simultaneously. The most important method of quench protection in the coupling magnet is the subdivision of the coil. Cold diodes and resistors are put across the subdivisions to reduce both the voltage to ground and the hot-spot temperature. The second method of quench protection is quench-back from the mandrel, which speeds up the spread of the normal region within the coils. Combining quench back with coil subdivision will reduce the hot spot temperature further. This paper explores the effect on the quench process of the number of coil sub-divisions, the quench propagation velocity within the magnet, and the shunt resistance.

42 ENGINEERING↗

Magnetic and Cryogenic Design of the MICE Coupling Solenoid Magnet System

The Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling in a short section of a realistic cooling channel using a muon beam at Rutherford Appleton Laboratory in the UK. The coupling magnet is a superconducting solenoid mounted around four 201MHz RF cavities, which produces magnetic field up to 2.6 T on the magnet centerline to keep muons within the iris of RF cavities windows. The coupling coil with inner radius of 750mm, length of 285mm and thickness of 102.5mm will be cooled by a pair of 1.5 W at 4.2 K small coolers. This paper will introduce the updated engineering design of the coupling magnet made by ICST in China. The detailed analyses on magnetic fields, stresses induced during the processes of winding, cool down and charging, and cold mass support assembly are presented as well.

42 ENGINEERING↗

AC Loss Analysis on the Superconducting Coupling Magnet in MICE

A pair of coupling solenoids is used in MICE experiment to generate magnetic field which keeps the muons within the iris of thin RF cavity windows. The coupling solenoids have a 1.5-meter inner diameter and will produce 7.4 T peak magnetic field. Three types of AC losses in coupling solenoid are discussed. The affect of AC losses on the temperature distribution within the cold mass during charging and rapid discharging process is analyzed also. The analysis result will be further confirmed by the experiment of the prototype solenoid for coupling solenoid, which will be designed, fabricated and tested at ICST.

42 ENGINEERING↗

Design, Synthesis, and Anti-inflammatory Properties of Orally Active 4-(Phenylamino)-pyrrolo[2,1-f][1,2,4]triazine p38[alpha] Mitogen-Activated Protein Kinase Inhibitors

A novel structural class of p38 mitogen-activated protein (MAP) kinase inhibitors consisting of substituted 4-(phenylamino)-pyrrolo[2,1- f][1,2,4]triazines has been discovered. An initial subdeck screen revealed that the oxindole-pyrrolo[2,1- f][1,2,4]triazine lead 2a displayed potent enzyme inhibition (IC 50 60 nM) and was active in a cell-based TNFalpha biosynthesis inhibition assay (IC 50 210 nM). Replacement of the C4 oxindole with 2-methyl-5- N-methoxybenzamide aniline 9 gave a compound with superior p38 kinase inhibition (IC 50 10 nM) and moderately improved functional inhibition in THP-1 cells. Further replacement of the C6 ester of the pyrrolo[2,1- f][1,2,4]triazine with amides afforded compounds with increased potency, excellent oral bioavailability, and robust efficacy in a murine model of acute inflammation (murine LPS-TNFalpha). In rodent disease models of chronic inflammation, multiple compounds demonstrated significant inhibition of disease progression leading to the advancement of 2 compounds 11b and 11j into further preclinical and toxicological studies.

59 BASIC BIOLOGICAL SCIENCES↗

A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen

We present a nanoparticle (NP) label/immunochromatographic electrochemical biosensor (IEB) for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. This IEB integrates the immunochromatographic strip with the electrochemical detector for transducing quantitative signals. The NP label, made of CdSe@ZnS, serves as a signal-amplifier vehicle. A sandwich immunoreaction was performed on the immunochromatographic strip. The captured NP labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane of the test zone. Experimental parameters (e.g., immunoreaction time, the amount of anti-PSA-NP conjugations applied) and electrochemical detection conditions (e.g., preconcentration potential and time) were optimized using this biosensor for PSA detection. The analytical performance of this biosensor was evaluated with serum PSA samples according to the “figure-of-merits” (e.g., dynamic range, reproducibility, and detection limit). The results were validated with enzyme-linked immunosorbent assay (ELISA) and show high consistency. It is found that this biosensor is very sensitive with the detection limit of 0.02 ng/mL PSA and is quite reproducible. This method is rapid, clinically accurate, and less expensive than other diagnosis tools for PSA; therefore, this IEB coupled with a portable electrochemical analyzer shows great promise for simple, sensitive, quantitative point-of-care testing of disease-related protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗