Search NASA⌕ Search

Engineering topics

Wu, Hongyu

Publications and source records attributed to Wu, Hongyu.

At least 19 records

Budget-Constrained Sizing of Renewable and Energy Storage Systems for Farm-Scale Ammonia Production Within the Food-Energy-Water Nexus

In the transition toward sustainable agriculture, farms have emerged as eco-friendly pioneers, harnessing clean hybrid wind and solar systems to improve farm performance. A concern in this paradigm is the effective sizing of renewable energy systems to ensure optimal energy use within budget considerations. This research focuses on optimizing renewable energy sizing in small-scale ammonia production to meet specific farm demands and enhance local resilience, emphasizing the interplay between environmental and economic factors. These findings promise increased energy efficiency and sustainability in this innovative agricultural sector. Additionally, our approach considers small-scale ammonia plant needs and the dynamic relationships between ammonia, water, and farm demands. Simulations demonstrate substantial cost savings in farm electricity consumption. Specifically, scenarios with renewable energy integration in the farm can reduce at least 13% electricity cost compared to a grid-dependent system in the 15-year simulation.

ammonia↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different datasets, i.e., 1) the unit generation dataset and 2) the system total inertia and headroom dataset, for the prediction of the frequency nadir. The training and testing datasets are generated through extensive generation scheduling simulations using Multi-timescale Integrated Dynamic and Scheduling (MI-DAS) toolbox on the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. Numerical results show that all five machine learning methods perform well in predicting the nadir frequency of the system. Among them, the gradient boosting and the XGBoost are clear winners yielding the best prediction accuracy in terms of four evaluation metrics.

data driven↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems: Preprint

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different sets of preprocess data for the prediction of the frequency nadir in the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. The training and testing data sets are collected by extensive generation scheduling simulations on the Multi-timescale Integrated Dynamic and Scheduling (MIDAS) toolbox. Numerical results show that all five machine learning methods can achieve high performance accuracy for power system nadir frequency estimation. Among them, the gradient boosting and the XGBoost are clear winners by providing the best prediction accuracy.

data driven↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of Stealthy False Data Injection Attacks in Unobservable Distribution Networks

In this paper, a composite scheme is proposed for detecting stealthy data manipulation attacks on distribution system which is unobservable with standard least squares based state estimators. This technique has three stages where the process of data imputation, voltage phasor estimation and the bad data detection are carried out in a systematic manner. The proposed approach is then integrated with moving target defense strategies which perturbs the network parameters to reveal stealthy false data injection attacks. The proposed approach is tested is validated on a three-phase, unbalanced 37-node distribution system and its results are presented. It is shown that the proposed approach has the ability to accurately detect the presence of FDI attacks using limited measurements (i.e., the test system is unobservable).

Rajasekaran, James K.↗

Impact of model predictive control-enabled home energy management on large-scale distribution systems with photovoltaics

Residential customers use more than one-quarter of the electricity in the world. Optimally managing home energy consumption is an effective way of easing the operational challenges facing the electric grid with increasing solar photovoltaics (PV). This paper studies the impact of the future proliferation of home energy management systems (HEMS) in the presence of PV on large-scale distribution systems. First, we present a stochastic HEMS model that minimizes residential customers' thermal discomfort and energy costs under uncertainty. The HEMS model schedules the optimal operations of residential appliances in the presence of PV within a mixed-integer linear programming-based model predictive control framework that links the proposed HEMS to a quasi-steady-state time-series simulation tool. Additionally, extensive simulations are conducted for a stand-alone residential home using two tariff structures and for 1977 homes on an 8,500-node distribution feeder. Simulation results quantify the impact of the future proliferation of HEMS on the large-scale distribution system with PV.

14 SOLAR ENERGY↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Systematic planning of moving target defence for maximising detection effectiveness against false data injection attacks in smart grid

Abstract Moving target defence (MTD) has been gaining traction to thwart false data injection attacks against state estimation (SE) in the power grid. MTD actively perturbs the reactance of transmission lines equipped with distributed flexible AC transmission system (D‐FACTS) devices to falsify the attacker's knowledge about the system configuration. However, the existing literature has not systematically studied what influences the detection effectiveness of MTD and how it can be improved based on the topology analysis. These problems are tackled here from the perspective of an MTD plan in which the D‐FACTS placement is determined. We first exploit the relation between the rank of the composite matrix and the detecting effectiveness. Then, we rigorously derive upper and lower bounds on the attack detecting probability of MTDs with a given rank of the composite matrix. Furthermore, we analyse existing planning methods and highlight the importance of bus coverage by D‐FACTS devices. To improve the detection effectiveness, we propose a novel graph theory–based planning algorithm to retain the maximum rank of the composite matrix while covering all necessary buses. Comparative results on multiple systems show the high detecting effectiveness of the proposed algorithm in both DC‐ and AC‐SE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Net Load Redistribution Attacks on Nodal Voltage Magnitude Estimation in AC Distribution Networks

A high penetration level of smart devices and communication networks increases the threat of cyber-attacks in the distribution system. In this paper, we model a hidden, coordinated, net load redistribution attack (NLRA) in an AC distribution system. Based on local information of an attack region, the attacker’s goal is to create violations in nodal voltage magnitude estimation. Acting as a system operator equipped with global AC state estimation and bad data detection, we validate the stealthiness of the hidden NLRA in multiple attack cases. Simulation results on a modified PG&E 69-node distribution system show the validity of the proposed NLRA. The influence of NLRA on the distribution system is assessed and the impact of attack regions, attack timing, and system observability is also revealed.

Zhang, Hang↗

An Interior-Point Solver for Optimal Power Flow Problem Considering Distributed FACTS Devices

In this paper, we propose an AC optimal power flow (ACOPF) model considering distributed flexible AC transmission system (D-FACTS) devices, in which the reactance of D-FACTS equipped lines are introduced as decision variables. This is motivated by increasing interests in using D-FACTS devices to address system operational and cyber-security concerns. First, D-FACTS devices can be incorporated in real-time operations for economic benefits such as managing power congestions and reducing system losses. Second, D-FACTS devices can be utilized by moving target defense (MTD), an emerging concept against cyber-attacks, to prevent attackers from knowing true system configurations. Therefore, system operators can use the proposed ACOPF model to achieve economic benefits and provide the setpoints of D-FACTS devices for MTD at the same time. In addition, we rigorously derive the gradient and Hessian matrices of the objective function and constraints, which are further used to build an interior-point solver of the proposed ACOPF. Numerical results on the IEEE 118-bus transmission system show the validity of the proposed ACOPF model as well as the efficacy of the interior-point solver in minimizing system losses and generation costs.

Liu, Bo↗

Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks

Moving target defense (MTD) is a defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation using distributed flexible AC transmission system (D-FACTS) devices. However, existing studies neglect to address a fundamental yet critical issue, i.e., the D-FACTS placement, by assuming that all lines are equipped with D-FACTS devices. Here, to tackle this problem, we first derive analytical necessary conditions and requirements on the D-FACTS placement for a complete MTD. Further, we propose sufficient conditions using a graph theory-based topology analysis to ensure that the MTD under the proposed D-FACTS placement has the maximum rank of its composite matrix, which is indicative of the MTD effectiveness. Based on the analytical conditions, we design D-FACTS placement algorithms by using the minimum number of D-FACTS devices to achieve the maximum MTD effectiveness. A novel MTD-based ACOPF model, in which the reactance of D-FACTS lines is introduced as decision variables, is proposed to find a trade-off between the system loss and the MTD effectiveness. Numerical results on 6-bus, IEEE 14-bus, and IEEE 118-bus systems show the efficacy of MTDs using the proposed D-FACTS placement algorithms in maximizing the composite matrix rank and detecting FDI attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Matrix Completion State Estimation in Distribution Systems

Due to the insufficient measurements in the distribution system state estimation (DSSE), full observability and redundant measurements are difficult to achieve without using the pseudo measurements. The matrix completion state estimation (MCSE) combines the matrix completion and power system model to estimate voltage by exploring the low-rank characteristics of the matrix. This paper proposes a robust matrix completion state estimation (RMCSE) to estimate the voltage in a distribution system under a low-observability condition. Tradition state estimation weighted least squares (WLS) method requires full observability to calculate the states and needs redundant measurements to proceed a bad data detection. The proposed method improves the robustness of the MCSE to bad data by minimizing the rank of the matrix and measurements residual with different weights. It can estimate the system state in a low-observability system and has robust estimates without the bad data detection process in the face of multiple bad data. The method is numerically evaluated on the IEEE 33-node radial distribution system. The estimation performance and robustness of RMCSE are compared with the WLS with the largest normalized residual bad data identification (WLS-LNR), and the MCSE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Matrix Completion State Estimation in Distribution Systems: Preprint

Due to the insufficient measurements in the distribution system state estimation (DSSE), full observability and redundant measurements are difficult to achieve without using the pseudo measurements. The matrix completion state estimation (MCSE) combines the matrix completion and power system model to estimate voltage by exploring the low-rank characteristics of the matrix. This paper proposes a robust matrix completion state estimation (RMCSE) to estimate the voltage in a distribution system under a low-observability condition. Tradition state estimation weighted least squares (WLS) method requires full observability to calculate the states and needs redundant measurements to proceed a bad data detection. The proposed method improves the robustness of the MCSE to bad data by minimizing the rank of the matrix and measurements residual with different weights. It can estimate the system state in a low-observability system and has robust estimates without the bad data detection process in the face of multiple bad data. The method is numerically evaluated on the IEEE 33-node radial distribution system. The estimation performance and robustness of RMCSE are compared with the WLS with the largest normalized residual bad data identification (WLS-LNR), and the MCSE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ADP-Based Home Energy Management System: A Case Study Using Dynamo: Preprint

This paper explores Home Energy Management System (HEMS) algorithms to minimize household cost while maintaining comfort when faced with uncertain weather, and demand. Specifically, we consider a HEMS that optimizes forward looking schedules for a home's heating, ventilation, and air conditioning (HVAC); water heater (WH); and electric vehicle (EV) charging while considering uncertainty in outside temperature, hot water usage, and non-controllable load (NCL). We adopt a Dynamic Programming (DP) formulation and utilize the Dynamic programming for Adaptive Modeling and Optimization (DYNAMO) toolkit to implement DP and approximate dynamic programming (ADP) algorithms. Simulation results under a single tariff plan compare the quality of the solution generated by ADP to that of DP, and show significant improvement in computation time while maintaining acceptable solution accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗