Search NASA⌕ Search

Engineering topics

Wu, Jayne

Publications and source records attributed to Wu, Jayne.

A disposable bulk-acoustic-wave microalga trapping device for real-time water monitoring

Recently, there has been an increase in the use of algal physiology as a convenient and useful indicator for monitoring of water quality in aquatic ecosystems. However, current methods for monitoring algal physiology are high-cost, power intensive, and have limited sensitivity for practical samples in which algal concentration is low. In order to alleviate these problems, we developed a simple-to-fabricate acoustophoretic particle trapping device that can effectively enrich various types of microalgae such as chlorella and diatoms for real-time monitoring of water quality. This microalgae trap is fabricated by embedding a piezoelectric resonator in a single channel. In comparison to previously reported acoustophoretic particle traps, this device has a simple structure and does not require sheath flows, which makes the device low cost and simple to fabricate and operate. Using Chlorella kessleri and the marine diatom Thalassiosira pseudonana as model algae, we report the microalgae trap has demonstrated notable particle trapping efficiencies between 82 % to 74 % for Chlorella with a through-flow of 0.5 μl/min to 2.7 μl/min and 85 % to 79 % for diatoms with a 0.5 μl/min to 4 μl/min through-flow. The trap has also shown to simultaneously trap Chlorella and diatoms at different heights of the microchannel. This device has high promise for trapping, separating and manipulating microalgae.

47 OTHER INSTRUMENTATION↗

Fe-based ceramic nanocomposite membranes fabricated via e-spinning and vacuum filtration for Cd 2+ ions removal

Here, vacuum filtered and polymer mixed e-spinning membranes (ESPMs) made from or doped with Fe-based nanomaterials were successfully fabricated to remove Cd 2+ ions from a neutral aqueous solution. The used Fe-based nanomaterials including FeOOH precursor Nanowires (NWs), α-Fe 2 O 3 NWs and Fe 3 O 4 nanoparticles (NPs) were synthesized by elevating the hydrothermal reaction temperature from 250 °C to 500 °C or doing post-heating treatment. The adsorption results showed that vacuum filtered membranes (VFMs) overall performed a better Cd 2+ ions removal behavior than e-spinning ones. Among them, VFM made from Fe 3 O 4 NPs has the highest adsorption capacity (qt) with the adsorption amount of Cd 2+ ions reaching about 29.3 mg/g within only 2 min due to the high specific surface area of NPs. Models of pseudo-first-order, pseudo-second-order and intraparticle diffusion were used to study the kinetics of Cd 2+ ions removal process, and a high correlation coefficient (R 2 ) of 0.99 was obtained when pseudo-second-order model was used. It was measured that the equilibrium rate constant of VFM made from Fe 3 O 4 NPs has reached about 0.28 g mg –1 min –1 , much smaller than those of other membranes, which suggested a high Cd 2+ ions removal efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-Induced Carbon-Based Smart Flexible Sensor Array for Multiflavors Detection

We report a flexible sensor array electronic tongue system that is fabricated on a polymer substrate by the laser direct writing process for multiflavor detection. Electronic tongue is a sensing system that is applied to detect different elements with the same sensor array. By analyzing responses from different measurement units, it enables a cross-sensitivity, namely, the ability of the system to responding to a range of different analytes in solution without specific functionalization of sensors. In this article, a six-unit sensing array system was fabricated by a laser direct writing process. Sensing units were introduced on a flexible polyamide surface. A high surface–volume ratio porous carbon structure was created by a laser-induced carbonization process, which provides stable conductive carbon electrodes with high sensitivity. Different surface treatments, such as gold plating, reduced-graphene oxide coating, and polyaniline coating, were accomplished for different measurement units. By applying principal component analysis, this sensing system shows a promising result for the detection of multiple flavors. The detection limit for each element is about 0.1 mM for NaCl and sugar solutions. Also, it is able to detect 10 –4 times diluted commercial table vinegar solution, which originally contains 5% acetic acid. The detection limit is theoretically lower than the human threshold of 10 mM for NaCl and sugar. Besides, the sensing system shows a high sensitivity and selectivity for mixed elements. Here, by mapping the data points, the sensor system could detect flavor combinations and provide a reliable prediction of analyte concentration ratios.

47 OTHER INSTRUMENTATION↗

A resettable in-line particle concentrator using AC electrokinetics for distributed monitoring of microalgae in source waters

Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V. The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.

30 DIRECT ENERGY CONVERSION↗

Bisphenol-A sensors on polyimide fabricated by laser direct writing for on-site river water monitoring at attomolar concentration

This work presents an aptamer-based, highly sensitive and specific sensor for atto- to femtomolar level detection of bisphenol A (BPA). Because of its widespread use in numerous products, BPA enters surface water from effluent discharges during its manufacture, use, and from waste landfill sites throughout the world. On-site measurement of BPA concentrations in water is important for evaluating compliance with water quality standards or environmental risk levels of the harmful compound in the environment. The sensor in this work is porous, conducting, interdigitated electrodes that are formed by laser-induced carbonization of flexible polyimide sheets. BPA-specific aptamer is immobilized on the electrodes as the probe, and its binding with BPA at the electrode surface is detected by capacitive sensing. The binding process is aided by ac electroosmotic effect that accelerates the transport of BPA molecules to the nanoporous graphene-like structured electrodes. The sensor achieved a limit of detection of 58.28 aM with a response time of 20 s. The sensor is further applied for recovery analysis of BPA spiked in surface water. In conclusion, this work provides an affordable platform for highly sensitive, real time, and field-deployable BPA surveillance critical to the evaluation of the ecological impact of BPA exposure.

36 MATERIALS SCIENCE↗