Engineering topics
Wu, M.
Publications and source records attributed to Wu, M..
Simulations of Microchannel Plate Sensitivity to <20 keV X-rays as a Function of Energy and Incident Angle
We present results of Monte Carlo simulations of microchannel plate (MCP) response to x-rays in the 250 eV to 20 keV energy range as a function of both x-ray energy and impact angle. The model is based on the model presented in Rochau et al. (2006). However, while the Rochau et al. (2006) model was two-dimensional, and their results only went to 5 keV, our results have been expanded to 20 keV, and our model has been incorporated into a three-dimensional Monte Carlo MCP model that we have developed over the past several years (Kruschwitz et al. 2011). X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV. The effect of x-ray penetration through multiple pores on MCP performance was studied and is presented.
Lead accumulation and association with Fe on Typha latifolia root from an urban brownfield site
Explore the source record for details and available documents.
Lead accumulation and association with Fe on Typha latifolia root from an urban brownfield site
N/A
Atto- and Femto-Litter Droplets of Concentrated Protein Solutions: Liquid-Liquid Phase Separation
No abstract available
Control of the Size and Distribution of Atto- and Femto-litter Protein Droplets: Liquid-liquid Phase Separation
No abstract available
Utilization of [14C]phenylalanine derived from arylphorin or free amino acid in Manduca sexta pharate adults
The role of arylphorin as a storage protein was studied using 14C-arylphorin. 14C-arylphorin was produced optimally by incubating one-half fat body from Manduca sexta fifth instar larvae at 22 degrees C for 24 h, in 1 ml of medium containing amino acids at 25% of their physiological concentration with [U-14C]-phenylalanine (phe) provided initially without nonlabeled phenylalanine. Nonlabeled phe was provided after 1 h at 16% of its physiological concentration. The specific activity of 14C-arylphorin produced in vitro was 30 times greater than that generated in vivo. Injection of 14C-arylphorin into pharate adults was used to study the distribution of 14C-phe derived from this protein into 14CO2 and tissues for comparison with injection of free 14C-phe during the middle (days 6 to 12 pharate adult) and late (days 12 to 17 pharate adult) stages of adult development. Appearance of 14CO2 from 14C-arylphorin as compared to 14C-phenylalanine showed a slower time course during both the middle and late stages of development, in keeping with the time needed for degradation of the protein. In accord with faster phe turnover near the end of adult development, total 14CO2 production was greater and the retention of 14C in hemolymph and fat body was less compared to the middle stage of development regardless of whether 14C-arylphorin or 14C-phe was injected. In the middle stage of development, the appearance of 14C in the cuticle and head parts was greater, whereas incorporation into abdomen and thorax was less than during the late stage of development. Since the pattern of 14C distribution from 14C-arylphorin and 14C-phe was similar, one major function of arylphorin must be as a storage protein replenishing the supply of free amino acids used for synthesis of adult tissues. These results also suggest a limited contribution of M. sexta arylphorin to formation of the cuticle subsequent to day-6 pharate adult.
Ecdysteroids affect in vivo protein metabolism of the flight muscle of the tobacco hornworm (Manduca sexta)
Ecdysteroid growth promotion of the dorsolongitudinal flight muscle of Manduca sexta was studied by measuring in vivo protein metabolism using both "flooding-dose" and "non-carrier" techniques. These procedures differ in that the former method includes injection of non-labelled phenylalanine (30 micromoles/insect) together with the [3H]amino acid. Injected radioactivity plateaued in the haemolymph within 7 min. With the flooding-dose method, haemolymph and intramuscular specific radioactivities were similar between 15 min and 2 h. Incorporation of [3H]phenylalanine into muscle protein was linear with either method between 30 and 120 min. Fractional rates (%/12 h) of synthesis with the flooding-dose technique were best measured after 1 h because of the initial delay in radioactivity equilibration. Estimation of body phenylalanine turnover with the non-carrier method showed 24-53%/h which was negligible with the flooding-dose method. Since the two methods yielded similar rates of protein synthesis, the large injection of non-labelled amino acid did not alter the rate of synthesis. Because the flooding-dose technique requires only a single time point measurement, it is the preferred method. The decline and eventual cessation of flight-muscle growth was mostly a consequence of declining protein synthesis though degradation increased between 76-86 h before eclosion and was relatively rapid. This decline in muscle growth could be prevented by treating pupae with 20-hydroxyecdysone (10 micrograms/insect). Protein accretion was promoted by a decline of up to 80% in protein breakdown, which was offset in part by a concurrent though much smaller decrease in protein synthesis. Therefore, ecdysteroids may increase flight-muscle growth by inhibiting proteolysis.
Observation of hard X-rays from the Crab pulsar and A0535+26
The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.