Search NASA⌕ Search

Engineering topics

Wu, Ming

Publications and source records attributed to Wu, Ming.

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

A generalized approach to x-ray data modeling for high-energy-density plasma experiments

Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, in this study, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.

Nagayama, Taisuke↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Weak Electron–Phonon Coupling and Enhanced Thermoelectric Performance in n-type PbTe–Cu 2 Se via Dynamic Phase Conversion

This study investigates Ga-doped n-type PbTe thermoelectric materials and the dynamic phase conversion process of the second phases via Cu 2 Se alloying. Introducing Cu 2 Se enhances its electrical transport properties while reducing its lattice thermal conductivity (κlat) via weak electron–phonon coupling. Additionally, Cu 2 Te and CuGa(Te/Se) 2 (tetragonal phase) nanocrystals precipitate during the alloying process, resulting in Te vacancies and interstitial Cu in the PbTe matrix. At room temperature, Te vacancies and interstitial Cu atoms serve as n-type dopants, increasing the carrier concentration and electrical conductivity from ≈1.18 × 10 19 cm –3 and ≈1870 S cm –1 to ≈2.26 × 10 19 cm –3 and ≈3029 S cm –1 , respectively. With increasing temperature, the sample exhibits a dynamic change in Cu 2 Te content and the generation of a new phase of CuGa(Te/Se) 2 (cubic phase), strengthening the phonon scattering and obtaining an ultralow k lat . Pb 0.975 Ga 0.025 Te-3%CuSe exhibits a maximum figure of merit of ≈1.63 at 823 K, making it promising for intermediate-temperature device applications.

36 MATERIALS SCIENCE↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Diffraction properties of cylindrically bent KAP crystals in energy range of 2.3–7.5 keV using synchrotron radiation

Verification of physics models and computer simulations are heavily reliant upon the accuracy of experimental measurements. Calibration of instrument responses becomes an important step to achieve this goal. This paper presents systematic studies of bent potassium acid phthalate (KAP) crystals using Lawrence Berkeley National Laboratories, Advanced Light Source, beamline 9.3.1 in the energy range of 2.3 to 7.5 keV. A set of KAP crystals, gradually bent from flat up to a 50.8 mm cylindrical curvature. The measured integrated reflectivity for this set of KAP crystals shows good agreement with the X-ray Oriented Program (XOP) calculations when adjusting the Debye–Waller temperature factor and using the multilamellar model in the calculations. Significant differences in rocking curve profiles were observed between experimental measurements and theory. A forward convolution model and software code were developed to include experimental parameters, allowing the investigation of the difference between measurements and calculations. After considering the experimental parameters, good agreements were obtained for the rocking curve profiles for all bending radii with a unique set of parameters. Our results show that XOP can be a useful and reliable tool to predict performance of cylindrically bent KAP crystals in this energy range.

Wu, Ming↗