Search NASA⌕ Search

Engineering topics

Wu, Wanwei

Publications and source records attributed to Wu, Wanwei.

At least 19 records

Energy Reconstruction and Calibration of the MicroBooNE LArTPC

The Liquid Argon Time Projection Chamber (LArTPC) is increasingly becoming the chosen technology for current and future precision neutrino oscillation experiments due to its superior capability in particle tracking and energy calorimetry. In LArTPCs, calorimetric information is critical for particle identification, which is the foundation for the neutrino cross-section and oscillation measurements as well as searches for beyond standard model physics. One of the primary challenges in employing LArTPC technology is characterizing its performance and quantifying the associated systematic uncertainties. MicroBooNE, the longest operating LArTPC to date, has performed numerous such measurements, including studies of detector physics and electromagnetic shower reconstruction. Here we present results on the operation and performance of the detector during its data taking, highlighting accomplishments toward calorimetric reconstruction, calibration, and detector physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting low energy signals from raw LArTPC waveforms using deep learning techniques — A proof of concept

Here, we investigate the feasibility of using deep learning techniques, in the form of a one-dimensional convolutional neural network (1D-CNN), for the extraction of signals from the raw waveforms produced by the individual channels of liquid argon time projection chamber (LArTPC) detectors. A minimal generic LArTPC detector model is developed to generate realistic noise and signal waveforms used to train and test the 1D-CNN, and evaluate its performance on low-level signals. We demonstrate that our approach overcomes the inherent shortcomings of traditional cut-based methods by extending sensitivity to signals with ADC values below their imposed thresholds. This approach exhibits great promise in enhancing the capabilities of future generation neutrino experiments like DUNE to carry out their low-energy neutrino physics programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting low energy signals from raw LArTPC waveforms using deep learning techniques -- A proof of concept

We investigate the feasibility of using deep learning techniques, in the form of a one-dimensional convolutional neural network (1D-CNN), for the extraction of signals from the raw waveforms produced by the individual channels of liquid argon time projection chamber (LArTPC) detectors. A minimal generic LArTPC detector model is developed to generate realistic noise and signal waveforms used to train and test the 1D-CNN, and evaluate its performance on low-level signals. We demonstrate that our approach overcomes the inherent shortcomings of traditional cut-based methods by extending sensitivity to signals with ADC values below their imposed thresholds. This approach exhibits great promise in enhancing the capabilities of future generation neutrino experiments like DUNE to carry out their low-energy neutrino physics programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge response and energy calibration of ProtoDUNE-SP

ProtoDUNE-SP at the CERN Neutrino Platform is a test bed liquid argon time pro-jection chamber (LArTPC) for the far-detector in the Deep Underground Neutrino Ex-periment (DUNE). Space charge eects, attenuation due to electronegative impurities,diusion, and electronics gain variations cause nonuniformities in charge depositionper unit length (dQ/dx) within a LArTPC. Corrections for space charge eects withmeasured electric-eld maps and attenuation with purity-monitor data were applied.A sample of cosmic-ray muons crossing the cathode is used to calibrate the detectorresponse to get a uniform dQ/dx over space and time. Using cosmic-ray stoppingmuons, which have a well-known energy loss per unit length (dE/dx), the absoluteenergy scale was determined. These calibration factors were uploaded to a databasefor use in further physics analysis.

43 PARTICLE ACCELERATORS↗

Muon Beam Dynamics and Spin Dynamics in the g-2 Storage Ring

The goal of the new g-2 experiment at fermilab is a measurement of the anomalous magnetic moment of the muon, with uncertainty of less than 140 ppb. The experimental method is to store a beam of polarized muons in a storage ring with pure vertical dipole field and electrostatic focusing, and to measure the precession frequency. Control of the systematics depends on unprecedented knowledge of the details of the phase space of the muon distribution. That knowledge is derived from direct measurements with scintillating fiber detectors that are inserted into the muon beam for diagnostic measurements, traceback straw tube tracking chambers, as well as the calorimeters that measure energy, time and position of the decay positrons. The interpretation of the measurements depends on a detailed model of the storage ring guide field. This invited talk presents results of studies of the distribution from the commissioning run of the experiment.

43 PARTICLE ACCELERATORS↗

Commissioning the Muon g-2 Experiment Electrostatic Quadrupole System

The Fermilab Muon g-2 experiment aims to measure the muon anomaly with a precision of 140 parts-per-billion (ppb) - a fourfold improvement over the 540 ppb precision obtained by the BNL Muon g-2 experiment. These high precision experiments both require a very uniform muon storage ring magnetic field that precludes the use of vertical-focusing magnetic quadrupoles. The Fermilab Electrostatic Quadrupole System (EQS) is the refurbished and upgraded BNL EQS, where this overview describes the Fermilab EQS and its recent operations.

43 PARTICLE ACCELERATORS↗

The Beam Dynamics and Beam Related Uncertainties in Fermilab Muon $g-2$ Experiment

The anomaly of the muon magnetic moment, $a_{\mu}\equiv (g-2)/2$, has played an important role in constraining physics beyond the Standard Model for many years. Currently, the Standard Model prediction for $a_{\mu}$ is accurate to 0.42 parts per million (ppm). The most recent muon $g-2$ experiment was done at Brookhaven National Laboratory (BNL) and determined $a_{\mu}$ to 0.54 ppm, with a central value that differs from the Standard Model prediction by 3.3-3.6 standard deviations and provides a strong hint of new physics. The Fermilab Muon $g-2$ Experiment has a goal to measure $a_{\mu}$ to unprecedented precision: 0.14 ppm, which could provide an unambiguous answer to the question whether there are new particles and forces that exist in nature. To achieve this goal, several items have been identified to lower the systematic uncertainties. In this work, we focus on the beam dynamics and beam associated uncertainties, which are important and must be better understood. We will discuss the electrostatic quadrupole system, particularly the hardware-related quad plate alignment and the quad extension and readout system. We will review the beam dynamics in the muon storage ring, present discussions on the beam related systematic errors, simulate the 3D electric fields of the electrostatic quadrupoles and examine the beam resonances. We will use a fast rotation analysis to study the muon radial momentum distribution, which provides the key input for evaluating the electric field correction to the measured $a_{\mu}$.

Wu, Wanwei↗

Electric Field Effects on the Muon Anomalous Precession Frequency in the Fermilab Muon g -2 Experiment [Slides]

The muon anomalous magnetic moment ( g -2) has played an important role in constraining physics beyond the Standard Model for many years. The Fermilab Muon g -2 Experiment has a goal to measure it to unprecedented precision: 0.14 ppm. To achieve this goal, we need to understand the systematic uncertainties associated with beam dynamics. We will present a study of the electric field correction to the muon anomalous precession frequency based on fast rotation analysis, which uses the evolution of beam bunch structure to determine the muon momentum distribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Dynamics in g-2 Storage Ring

The muon anomalous magnetic moment has played an important role in constraining physics beyond the Standard Model. The Fermilab Muon g-2 Experiment has a goal to measure it to unprecedented precision: 0.14 ppm. To achieve this goal, we must understand the beam dynamics systematic effects in the muon storage ring. We will present the muon beam dynamics and discuss two specific topics here: the beam resonance which is related to the muon loss and the fast rotation analysis to determine the muon momentum distribution.

43 PARTICLE ACCELERATORS↗