SU-E-T-655: Quantifying the Dosimetric Characteristics of a Calypso Compatible Radiotherapy Treatment Couch with Angular Transmission Functions

Purpose: To quantified the dosimetric characteristics of a Calypso compatible radiotherapy couch using continuously scanned transmission factor as a function of gantry angle. Methods: Radiation dose as a function of gantry angle was measured with an ionization chamber at the center of a 30 cm diameter cylindrical phantom placed on Qfix kVue Calypso compatible couch. A 3-D scanner was employed to continuously scan the dose during an arc rotation delivery. Nearly continuous transmission curves of 0.03° step size were obtained from IEC gantry angle 90° to180° for 6 MV and 15 MV photon beams at three couch longitudinal positions (due to longitudinally non-uniform shape of the couch rails) with rails both at the center and on sides. The transmission curves were evaluated to assess the attenuation by the couch. They were also compared to those of a carbon fiber couch top. Results: The scanned transmission curves of the Calypso comptible couch showed fine details of the couch transmission as a function of gantry angle. The attenuation by the couch varied from 2.4% to 12.9% for the 6 MV photo beam and from 1.8% to 8.9% for the 15 MV photon beam depending on the gantry angle. The attenuation by the flat couch top is only approximately 2 to 3%, but by the rail is much more significant. Because the rails are not uniformly shaped in the longitudinal direction, attenuation by the rail for the same gantry angle varied with the rail longitudinal position. The transmission curves of the carbon fiber couch top are nearly identical to those of the Calypso compatible couch top. Conclusion: The Calypso compatible couch attenuates radiation by 2.4%–12.9% and 1.8%–8.9% for 6 MV and 15 MV photon beams, respectively. The attenuation by the rails is much more significant than the flat couch top.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-755: Timing Characteristics of Proton and Carbon Ion Treatments Using a Synchrotron and Modulated Scanning

Purpose: The time required to deliver a treatment impacts not only the number of patients that can be treated each day but also the accuracy of delivery due to potential movements of patient tissues. Both macroscopic and microscopic timing characteristics of a beam delivery system were studied to examine their impacts on patient treatments. Methods: 35 patients were treated during a clinical trial to demonstrate safety and efficacy of a Siemens Iontris system prior to receiving approval from the Chinese Food and Drug Administration. The system has a variable cycle time and can provide proton beams from 48 to 221 MeV/n and carbon ions from 86 to 430 MeV/n. A modulated scanning beam delivery technique is used where the beam remains stationary at each spot aiming location and is not turned off while the spot quickly moves from one aiming location to the next. The treatment log files for 28 of the trial patients were analyzed to determine several timing characteristics. Results: The average portal time per target dose was 172.5 s/Gy for protons and 150.7 s/Gy for carbon ions. The maximum delivery time for any portal was less than 300 s. The average dwell time per spot was 12 ms for protons and 3.0 ms for carbon ions. The number of aiming positions per energy layer varied from 1 to 258 for protons and 1 to 621 for carbon ions. The average spill time and cycle time per energy layer were 1.20 and 2.68 s for protons and 0.95 and 4.73 s for carbon ions respectively. For 3 of the patients, the beam was gated on and off to reduce the effects of respiration. Conclusion: For a typical target volume of 153 cc as used in this clinical trial, the portal delivery times were acceptable.

60 APPLIED LIFE SCIENCES↗

Pressure-induced phase transitions in rubidium azide: Studied by in-situ x-ray diffraction

We present the in-situ X-ray diffraction studies of RbN{sub 3} up to 42.0 GPa at room temperature to supplement the high pressure exploration of alkali azides. Two pressure-induced phase transitions of α-RbN{sub 3} → γ-RbN{sub 3} → δ-RbN{sub 3} were revealed at 6.5 and 16.0 GPa, respectively. During the phase transition of α-RbN{sub 3} → γ-RbN{sub 3}, lattice symmetry decreases from a fourfold to a twofold axis accompanied by a rearrangement of azide anions. The γ-RbN{sub 3} was identified to be a monoclinic structure with C2/m space group. Upon further compression, an orthogonal arrangement of azide anions becomes energetically favorable for δ-RbN{sub 3}. The compressibility of α-RbN{sub 3} is anisotropic due to the orientation of azide anions. The bulk modulus of α-RbN{sub 3} is 18.4 GPa, quite close to those of KN{sub 3} and CsN{sub 3}. By comparing the phase transition pressures of alkali azides, their ionic character is found to play a key role in pressure-induced phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.

60 APPLIED LIFE SCIENCES↗

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-27: A Tool for Routine Quality Assurance of Radiotherapy Dose Calculation Software

Purpose: Dose calculation software is thoroughly evaluated when it is commissioned; however, evaluation of periodic software updates is typically limited in scope due to staffing constraints and the need to quickly return the treatment planning system to clinical service. We developed a tool for quickly and comprehensively testing and documenting dose calculation software against measured data. Methods: A tool was developed using MatLab (The MathWorks, Natick, MA) for evaluation of dose calculation algorithms against measured data. Inputs to the tool are measured data, reference DICOM RT PLAN files describing the measurements, and dose calculations in DICOM format. The tool consists of a collection of extensible modules that can perform analysis of point dose, depth dose curves, and profiles using dose difference, distance-to-agreement, and the gamma-index. Each module generates a report subsection that is incorporated into a master template, which is converted to final form in portable document format (PDF). Results: After each change to the treatment planning system, a report can be generated in approximately 90 minutes. The tool has been in use for more than 5 years, spanning 5 versions of the eMC and 4 versions of the AAA. We have detected changes to the algorithms that affected clinical practice once during this period. Conclusion: Our tool provides an efficient method for quality assurance of dose calculation software, providing a complete set of tests for an update. Future work includes the addition of plan level tests, allowing incorporation of, for example, the TG-119 test suite for IMRT, and integration with the treatment planning system via an application programming interface. Integration with the planning system will permit fully-automated testing and reporting at scheduled intervals.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-98: Dependence of Radiotherapy Couch Transmission Factors On Field Size and Couch-Isocenter Distance

Purpose: The dosimetric effect of the treatment couch is non-negligible in today's radiotherapy treatment. To accurately include couch in dose calculation, we investigated the dependence of couch transmission factors on field size and couch-isocenter distance. Methods: Couch transmission factors for Varian Exact Couch were determined by taking the ratios of ionization of a posterior-anterior beam with and without the couch in the beam path. Measurements were performed at the isocenter using a PTW cylindrical ionization chamber (Model 31030) with an Aluminum buildup cap of 1.1 cm thick for the 6 MV photon beam. Ionization readings for beam sizes ranging from 2 × 2 cm2 to 40 × 40 cm2 were taken. Transmission factors for couch-isocenter distances ranging from 3 cm to 20 cm were also investigated. Results: The couch transmission factors increased with the field size approximately in an exponential manner. For the field sizes that we tested, the transmission factor ranged from 0.976 to 0.992 for couch-isocenter distance of 3 cm. The transmission factor was also monotonically dependent on couch-isocenter separation distance, but in a lighter magnitude. For the tested couch heights, the transmission factor ranged from 0.974 – 0.972 for 2 × 2 cm2 field size and 0.992 – 0.986 for 40 × 40 cm2 field size. The dependence on couch-isocenter distance is stronger for larger field size. Conclusions: The transmission factor of a radiotherapy treatment couch increases with field size of the radiation beam and its distance from the isocenter. Such characterization of the couch transmission factor helps improve the accuracy of couch modeling for radiotherapy treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changed through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.

60 APPLIED LIFE SCIENCES↗

SU-E-T-417: A Method for Predicting and Correcting the Dosimetric Effect of a Radiotherapy Treatment Couch in Actual Treatment Position

Purpose: Although radiation attenuation by the treatment couch can be included in the calculation of radiotherapy dose, difference between planned and actual treatment couch positions can generate significant dose discrepancies. We propose a method to predict and correct the dosimetric effect of the couch in actual treatment position. Methods: The couch transmission factor, T, varies with beam angle, G, couch lateral position, x, and vertical position, y, i.e., T=T(x,y,G). If T(x,y,G) is known for a fixed couch vertical position y=h, the transmission of central-axis beam (CAX) T(x,y,G) can be obtained by T(x,y,G)=T(x{sup +},h,G), where x{sup +}=x-(y-h)tan(G) and G is the angle between the beam and the vertical axis. Similarly, the transmission of any off-CAX point can be obtained using a similar formula. We measured CAX couch transmission at a fixed couch vertical position over the couch lateral motion range for all gantry angles by continuously scanning rotating arc beams. A 2D couch transmission correction matrix can thus be generated from T(x,h,G) for each treatment field for the actual couch position. By applying the transmission correction matrix to the planned field dose, the couch effect can be predicted and corrected. To verify this method, we measured couch transmission T(x, y=10cm, G=225°)(225°=IEC 135°) and compared to that obtained from equivalent T(x{sup +}, y=3cm, G=225°) over the range of lateral motion with a step size of 2 cm . Results: The measured couch transmission factors T(x, y=10cm, G=225°) are in excellent agreement with those obtained from the equivalent T(x{sup +}, y=3cm, G=225°). The mean difference is 0.00406±0.00135. Conclusion: The couch transmission correction matrix for any couch position and beam angle can be obtained from one set of scanning measurements at a fixed couch vertical position. The dosimetric effect of the treatment couch can be predicted and corrected by applying the couch transmission correction to the planned dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-425: Spherical Dose Distributions for Radiosurgery Using a Standardized MLC Plan

Purpose: To investigate a standardized MLC treatment plan to generate small spherical dose distributions. Methods: The static virtual cone plan comprised six table positions with clockwise and counterclockwise arcs having collimator angles 45 and 135 degrees, respectively, at each position. The central two leaves of a 2.5 mm leaf width MLC were set to a constant gap. Control points were weighted proportional to the sine of the gantry angle. Plans were created for the 10 MV flattening-filter-free beam of a TrueBeam STx (Varian Medical Systems) with gaps of 1, 1.5, 2, and 3 mm and were delivered to a phantom containing radiochromic film. Dose was calculated using the Eclipse AAA (Varian Medical Systems). A dynamic plan in which the table and gantry moved simultaneously with 1.5 mm gap was also created and delivered using the TrueBeam developer mode. Results: The full-width-half-max (FWHM) varied with leaf gap, ranging from 5.2 to 6.2 mm. Calculated FWHM was smaller than measured by 0.7 mm for the 1 mm gap and ≤ 0.4 mm for the larger gaps. The measured-to-calculated dose ratio was 0.93, 0.96, 1.01, and 0.99 for 1 mm, 1.5 mm, 2 mm, and 3 mm gaps, respectively. The dynamic results were the same as the static. The position deviations between the phantom target position and the center of the dose distribution were < 0.4 mm. Conclusion: The virtual cone can deliver spherical dose distributions suitable for radio surgery of small targets such as the trigeminal nerve. The Eclipse AAA accurately calculates the expected dose, particularly for leaf gap ≥ 1.5 mm. The measured dose distribution is slightly larger than the calculation, which is likely due to systematic leaf position error, isocenter variation due to gantry sag and table eccentricity, and inaccuracy in MLC leaf end modeling.

60 APPLIED LIFE SCIENCES↗

SU-E-T-507: Interfractional Variation of Fiducial Marker Position During HDR Brachytherapy with Cervical Interstitial Needle Template

Purpose: HDR brachytherapy using interstitial needle template for cervical cancer is commonly delivered in 4-5 fractions. Routine verification of needle positions before each fraction is often based on radiographic imaging of implanted fiducial markers. The current study evaluated interfractional displacement of implanted fiducial markers using CT images. Methods: 9 sequential patients with cervical interstitial needle implants were evaluated. The superior and inferior borders of the target volumes were defined by fiducial markers in planning CT. The implant position was verified with kV orthogonal images before each fraction. A second CT was acquired prior 3rd fraction (one or 2 days post planning CT). Distances from inferior and superior fiducial markers to pubic symphysis plane (perpendicular to vaginal obtulator)were measured. Distance from needle tip of a reference needle (next to the inferior marker) to the pubic symphysis plane was also determined. The difference in fiducial marker distance or needle tip distance between planning CT and CT prior 3rd fraction were measured to assess markers migration and needle displacement. Results: The mean inferior marker displacement was 4.5 mm and ranged 0.9 to 11.3 mm. The mean superior marker displacement was 2.7 mm and ranged 0 to 10.4 mm. There was a good association between inferior and superior marker displacement (r=0.95). Mean averaged inferior and superior marker displacement was 3.3 mm and ranged from 0.1 to 10.9 mm, with a standard deviation of 3.2 mm. The mean needle displacement was 5.6 mm and ranged 0.2 to 15.6 mm. Needle displacements were reduced (p<0.05) after adjusting according to needle-to-fiducials distance. Conclusion: There were small fiducial marker displacements between HDR fractions. Our study suggests a target margin of 9.7 mm to cover interfractional marker displacements (in 95% cases) for pretreatment verification based on radiographic imaging.

60 APPLIED LIFE SCIENCES↗

Pressure-induced structural phase transition in AlN:Mg and AlN:Co nanowires

High-pressure behaviors of AlN:Mg and AlN:Co nanowires have been investigated by in situ angle dispersive synchrotron X-ray diffraction up to 41.5 GPa and 38.2 GPa, respectively. Their corresponding pressure-induced wurtzite-to-rocksalt phase transitions start at 17.7 GPa and 15.0 GPa and complete at 33.2 GPa and 31.0 GPa, respectively. The phase-transition routes are not affected by the doped ions, while the phase transition pressures are lower than that of pure AlN nanowires. The distinct high-pressure behaviors are ascribed to the doped ions, which reduce the formation energy of cation vacancies and induce Al vacancies defects together with substitution defects, resulting in lattice distortion and affecting structural stability and phase transition pressure. - Graphical abstract: The high-pressure behaviors of AlN:Mg and AlN:Co nanowires have been investigated by in situ angle dispersive synchrotron X-ray diffraction. - Highlights: • The high-pressure behaviors of AlN:Mg and AlN:Co nanowires have been investigated. • The pressure-induced wurtzite-to-rocksalt phase transitions have been observed. • The phase transition pressures are lower than that of pure AlN nanowires. • The distinct high-pressure behaviors are ascribed to the dopants. • The vacancy defects and substitution defects influence structural stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The novel phase transition of NaBi(WO{sub 4}){sub 2} under high pressure

The Raman and synchrotron angle-dispersive X-ray diffraction studies have been performed on NaBi(WO{sub 4}){sub 2} under high pressure up to 30.7 and 36.2 GPa, respectively, at room temperature. With pressure increases to ∼7.0 GPa, the structure of NaBi(WO{sub 4}){sub 2} begins to transform from tetragonal (I4{sub 1}/a) into monoclinic (P2/m), and the phase transition completes around 13 GPa. With pressure higher than 29.0 GPa, the NaBi(WO{sub 4}){sub 2} turns into amorphous state. The random arrangement of Na{sup +} and Bi{sup 3+} in short-range ordered scheelite NaBi(WO{sub 4}){sub 2} results in the tetragonal to monoclinic phase transition, which is different from that observed in AWO{sub 4} tungstates and AMoO{sub 4} molybdates (A=Ca, Sr, Ba, Pb, Eu, Cd). - Graphical abstract: The NaBi(WO{sub 4}){sub 2} transforms from tetragonal into monoclinic, which starts around 7 GPa and completes at about 13 GPa. With pressure higher than 29 GPa, the NaBi(WO{sub 4}){sub 2} turns into amorphous state. Highlights: ► Raman and X-ray diffraction studies performed on NaBi(WO{sub 4}){sub 2} up to 30.7 and 36.2 GPa, respectively. ► The tetragonal (I4{sub 1}/a) into monoclinic (P2/m) phase transition is determined. ► With pressure higher than 29 GPa, the NaBi(WO{sub 4}){sub 2} ultimately turns into amorphous state. ► The ambient pressure bulk modulus and volume of tetragonal and monoclinic phases are obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INTERSTELLAR GAS FLOW PARAMETERS DERIVED FROM INTERSTELLAR BOUNDARY EXPLORER-Lo OBSERVATIONS IN 2009 AND 2010: ANALYTICAL ANALYSIS

Neutral atom imaging of the interstellar gas flow in the inner heliosphere provides the most detailed information on physical conditions of the surrounding interstellar medium (ISM) and its interaction with the heliosphere. The Interstellar Boundary Explorer (IBEX) measured neutral H, He, O, and Ne for three years. We compare the He and combined O+Ne flow distributions for two interstellar flow passages in 2009 and 2010 with an analytical calculation, which is simplified because the IBEX orientation provides observations at almost exactly the perihelion of the gas trajectories. This method allows separate determination of the key ISM parameters: inflow speed, longitude, and latitude, as well as temperature. A combined optimization, as in complementary approaches, is thus not necessary. Based on the observed peak position and width in longitude and latitude, inflow speed, latitude, and temperature are found as a function of inflow longitude. The latter is then constrained by the variation of the observed flow latitude as a function of observer longitude and by the ratio of the widths of the distribution in longitude and latitude. Identical results are found for 2009 and 2010: an He flow vector somewhat outside previous determinations ({lambda}{sub ISM{infinity}} = 79.{sup 0}0+3.{sup 0}0(-3.{sup 0}5), {beta}{sub ISM{infinity}} = -4.{sup 0}9 {+-} 0.{sup 0}2, V{sub ISM{infinity}} 23.5 + 3.0(-2.0) km s{sup -1}, T{sub He} = 5000-8200 K), suggesting a larger inflow longitude and lower speed. The O+Ne temperature range, T{sub O+Ne} = 5300-9000 K, is found to be close to the upper range for He and consistent with an isothermal medium for all species within current uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Sulfuric Acid Pretreatment and Enzymatic Hydrolysis of Photoperiod Sensitvie Sorghum for Ethanol Production

Photoperiod sensitive (PS) sorghum, with high soluble sugar content, high mass yield and high drought tolerance in dryland environments, has great potential for bioethanol production. The effect of diluted sulfuric acid pretreatment on enzymatic hydrolysis was investigated. Hydrolysis efficiency increased from 78.9 to 94.4% as the acid concentration increased from 0.5 to 1.5%. However, the highest total glucose yield (80.3%) occurred at the 1.0% acid condition because of the significant cellulose degradation at the 1.5% concentration. Synchrotron wide-angle X-ray diffraction was used to study changes of the degree of crystallinity. With comparison of cellulosic crystallinity and adjusted cellulosic crystallinity, the crystalline cellulose decreased after low acidic concentration (0.5%) applied, but did not change significantly, as the acid concentration increased. Scanning electron microscopy was also employed to understand how the morphological structure of PS sorghum changed after pretreatment. Under current processing conditions, the total ethanol yield is 74.5% (about 0.2 g ethanol from 1 g PS sorghum). A detail mass balance was also provided.

09 BIOMASS FUELS↗

The microstructure of near-equiatomic B2/f.c.c. FeNiMnAl alloys

A microstructural analysis of two FeNiMnAl alloys, Fe{sub 30}Ni{sub 20}Mn{sub 30}Al{sub 20} and Fe{sub 25}Ni{sub 25}Mn{sub 30}Al{sub 20}, was performed by a combination of atom probe tomography and transmission electron microscopy techniques. Although the microstructures of both alloys, which consist of alternating platelets aligned along < 100> of the B2-ordered phase, are similar to B2/b.c.c. two-phase alloys previously observed in the FeNiMnAl system, the two phases present in the current alloys are B2-ordered and f.c.c., with the latter phase being heavily twinned. Very fine ({approx} 5 nm) precipitates, whose chemistry was similar to that of the f.c.c. (Fe, Mn)-rich phase, were found within the B2 (Ni, Al)-rich phase in both alloys. - Highlights: {yields} The microstructures of the novel alloys Fe{sub 30}Ni{sub 20}Mn{sub 30}Al{sub 20} and Fe{sub 25}Ni{sub 25}Mn{sub 30}Al{sub 20} were characterized. {yields} Atom probe tomography and transmission electron microscopy were used in the study. {yields} A < 100>-aligned B2-ordered phase and heavily-twinned f.c.c. phase were present. {yields} Very fine (Fe, Mn)-rich precipitates were found within the B2 (Ni, Al)-rich phase.

36 MATERIALS SCIENCE↗