Search NASA⌕ Search

Engineering topics

Wu, Xiaodong

Publications and source records attributed to Wu, Xiaodong.

Thermal Stability and Lattice Strain Evolution of High-Nb-Containing TiAl Alloy under Low-Cycle-Fatigue Loading

The micromechanical behavior and the effect of temperature on the micromechanical mechanism of high-Nb-containing TiAl alloy during low-cycle fatigue still remain uncertain. Herein, in situ and ex situ synchrotron-based high-energy X-ray (HEXRD) experiment results reveal that the gamma and omega(o) phases suffer compressive lattice strains but the lattice strain in the alpha(2) phase evolves from tensile to compressive during low-cycle fatigue at 900 degrees C. In addition, the three phases suffer compressive lattice strains during cooling to room temperature, which could result in larger compressive lattice strains in gamma and omega(o) phases and the change of the lattice strain state in the alpha(2) phase. The peak-broadening results show gamma recrystallization is dominant in the interrupted low-cycle-fatigue samples, whereas inhomogeneous deformation occurs in the failed low-cycle-fatigue samples. The performed synchrotron diffraction experiments offer a deeper insight into the phase transformations and micromechanism of TiAl alloy during low-cycle fatigue.

cyclic stress-strain behavior↗

Quasi-operando quantification of Cu(ii) ions in Cu-SSZ-13 catalyst by an NH 3 temperature-programmed reduction method

In this work, a quasi-operando NH3 temperature-programmed reduction method (NH 3 -TPR), with N 2 :Cu = 1:1, is developed to quantify total Cu(II) ions in Cu-SSZ-13 quenched from SCR-relevant reactions, and its accuracy is confirmed by in situ EPR. [Cu(OH)] + -Z and Cu 2+ -2Z can be further distinguished by NH 3 reduction temperatures, and their different reducibility in SCR is revealed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical roles of Cu(OH)2 in low-temperature moisture-induced degradation of Cu-SAPO-34 SCR catalyst: Correlating reversible and irreversible deactivation

Cu-SAPO-34 selective catalytic reduction (SCR) catalyst deactivates upon exposure to water vapor at temperatures lower than 100 °C, which deteriorates its application prospects. The deactivation under cycled aging-regeneration conditions can be categorized into two stages, namely reversible and irreversible deactivation. Based on SCR reaction tests, and characterizations with diffuse reflection infrared Fourier transform spectroscopy (DRIFTS), NH3 temperature-programmed desorption (NH3-TPD) and H2 temperature-programmed reduction (H2-TPR), it is concluded that the transformation of SCR active isolated Cu(II) ions to Cu(OH)2 is critical to both types of deactivation. Within the frame of reversible deactivation, Cu(OH)2 is converted back to SCR active Cu(II) ions by interacting with Brønsted acid sites during high-temperature regeneration. However, interactions between Cu(OH)2 and hydrolyzed framework Al lead to the formation of CuAl2O4-like species, causing permanent loss of active Cu(II) ions and thus, irreversible deactivation. The authors from Tsinghua University would like to acknowledge the financial support from projects of China Science and Technology Exchange Centre (No. 2016YFE0126600) and the National Key R&D Program of China (No. 2017YFC0211102). YM also acknowledges Tsinghua Scholarship for Overseas Graduate Studies for a visit to the Pacific Northwest National Laboratory (PNNL). PNNL is operated by Battelle for the US Department of Energy (DOE) under contract DE-AC05-76RL01830. FG is supported by DOE, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office.

Cu-SAPO-34, low-temperature deactivation, reversib↗

Cyclic deformation and lattice strain distribution of high Nb containing TiAl alloy

Low cycle fatigue of lamellar TiAl with 8.5 at.-%Nb was studied with a total strain amplitude of 0.28% at three temperatures: room temperature, 750°C and 900°C. At room temperature, the material exhibited cyclic hardening and the fracture mode was mainly interlamellar. At 750°C and 900°C, the material showed cyclic softening and the fracture mode was translamellar. The lattice strain in γ phase was almost tensile and larger tensile lattice strain in γ phase seems detrimental. Besides, the opposite direction of {201} γ and {100} α2 lead to crack propagation along α 2 /γ interfaces. B2/β o phase always suffered compressive lattice strain in the tests. Finally, the destruction of lamellar microstructure was the reason for colony refinement at 750°C and 900°C.

phase transformation↗

Optimization of Tensile and Corrosion Properties of Dissimilar Friction Stir Welded AA2024-7075 Joints

In this work, we performed some joining experiments of dissimilar aluminum alloys AA2024-T351 and AA7075-T651 using friction stir welding (FSW) technique with different process parameters (rotational speed, welding speed and plunge depth). Response surface methodology based on a central composite rotatable design was used to establish the mathematical models predicting the tensile properties and corrosion rate of dissimilar FSW joints with some high confidence level. Analysis of variance method was employed to verify the developed models. Besides, the influences of FSW process parameters on tensile and corrosion properties of joints were analyzed. In order to obtain a desirable combination property of the dissimilar FSW joints, the optimum process parameters after experimental verification were proposed as: rotational speed 1495 rev/min, welding speed 187 mm/min and plunge depth 0.03 mm. This verification illustrated that the developed models are appropriate for the modeling and optimization of process.

36 MATERIALS SCIENCE↗

Multisource Rotating Shield Brachytherapy Apparatus for Prostate Cancer

Purpose: Our purpose is to present a novel multisource rotating shield brachytherapy (RSBT) apparatus for the simultaneous precise angular and linear positioning of partially shielded {sup 153}Gd brachytherapy sources in interstitial needles for the treatment of locally advanced prostate cancer. It is designed to lower the dose to nearby healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy techniques. Methods and Materials: Following needle implantation through the patient template, an angular drive mechanism is docked to the patient template. Each needle is coupled to a multisource afterloader catheter by a connector passing through a shaft. The shafts are rotated about their axes by translating a moving template between 2 stationary templates. The shafts' surfaces and moving template holes are helically threaded with the same pattern such that translation of the moving template causes simultaneous rotation of the shafts. The rotation of each shaft is mechanically transmitted to the catheter-source-shield combination, inside the needles, via several key-keyway pairs. The catheter angles are simultaneously incremented throughout treatment, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multisource afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a wire that controls catheter depth in a needle. Results: Treatment plans demonstrated that RSBT with the proposed apparatus reduced urethral D{sub 0.1cm{sup 3}} (the minimum dose delivered to the hottest 0.1cm{sup 3} of the urethra) below that of conventional high-dose-rate brachytherapy by 31% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with the proposed multisource RSBT apparatus by use of nineteen 62.4-GBq {sup 153}Gd sources was 122 minutes. Conclusions: The proposed RSBT delivery apparatus enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable time frame.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multihelix rotating shield brachytherapy for cervical cancer

Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and comparison. For all the generated treatment plans, the D{sub 90} of the HR-CTV in units of equivalent dose in 2 Gy fractions (EQD2) was escalated until the D{sub 2cc} (minimum dose to hottest 2 cm{sup 3}) tolerance of either the bladder (90 Gy{sub 3}), rectum (75 Gy{sub 3}), or sigmoid colon (75 Gy{sub 3}) was reached. Results: Treatment time changed for H-RSBT versus S-RSBT by −7.62% to 1.17% with an average change of −2.8%, thus H-RSBT treatments times tended to be shorter than for S-RSBT. The HR-CTV D{sub 90} also changed by −2.7% to 2.38% with an average of −0.65%. Conclusions: H-RSBT is a mechanically feasible delivery technique for use in the curved applicators needed for cervical cancer brachytherapy. S-RSBT and H-RSBT were clinically equivalent for all patients considered, with the H-RSBT technique tending to require less time for delivery.

60 APPLIED LIFE SCIENCES↗

Paddle-based rotating-shield brachytherapy

Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16.6, 12.9, 7.2, 3.7, and 1.7 Gy{sub 10}, respectively. P-RSBT HR-CTV D{sub 90}-values were insensitive to the paddle size for paddles angled at less than 60°. Increasing the paddle angle from 5° to 60° resulted in only a 0.6 Gy{sub 10} decrease in HR-CTV D{sub 90} on average for five cases when the delivery times were set to 15 min/fx. The HR-CTV D{sub 90} decreased to 2.5 and 11.9 Gy{sub 10} with paddle angles of 90° and 120°, respectively. Conclusions: P-RSBT produces treatment plans that are dosimetrically and temporally superior to those of S-RSBT and D-RSBT, although P-RSBT systems may be more mechanically challenging to develop than S-RSBT or D-RSBT. A P-RSBT implementation with 4–6 shield paddles would be sufficient to outperform S-RSBT and D-RSBT if delivery times are constrained to less than 15 min/fx.

60 APPLIED LIFE SCIENCES↗