Investigation of island size effect on radiation distribution during attached and detached plasmas in the island divertor of W7-X
Not Available
Engineering topics
Publications and source records attributed to Wurden, G. A..
Not Available
Explore the source record for details and available documents.
The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.
A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.
The low magnetic shear in the Wendelstein 7-X (W7-X) stellarator makes it feasible to shape the separatrix by the large islands constituting an island-divertor, and this can be exploited to access various magnetic configurations, including samples of different internal island sizes and locations. To investigate the configuration effects on the plasma confinement, a configuration scan was performed by changing the coil currents to vary the rotational transform between values 5/4 and 5/6 at the plasma boundary with different power levels (2, 4, 6 MW) of electron cyclotron resonance heating (ECRH) at a maximum plasma density of 8 × 10 19 m -2 . neutral beam injection (NBI) heating was also applied during some configurations of the scan to create a density ramp and access high densities beyond the X2 ECRH cutoff. For the magnetic configurations, where the 5/5 and 5/6 island chains were moved closer to separatrix but remaining inside the last closed flux surface, the electron cyclotron emission shows that an electron temperature, T e , pedestal develops already during ECRH heated plasma buildup phase indicating a transport barrier, and the barrier sustains irrespective of changed plasma heating conditions such as NBI in the later part of discharge. The transport barrier is broken by subsequent fast crashes, observed with multiple plasma diagnostics with characteristics such as tokamak edge localized modes, and the corresponding crash amplitude and frequency vary with plasma pressure. The impact of the transport barrier on plasma confinement can be seen through the increased core T e profile, which could be responsible for the overall increase in the stored diamagnetic energy by approximately 10% for these configurations. After the plasma heating is terminated, a backwards transition to a degraded confinement state is also observed. These observations indicate a configuration triggered high confinement mode in low shear W7-X. This work focuses on the occurrence of this transport barrier for different magnetic configurations and its relation to internal magnetic islands.
In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. A new mid-size stellarator is needed to retire risks and innovate towards a high performance, economically attractive, stellarator Fusion Pilot Plant. In this presentation we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new and modern mid-size stellarator research facility. A new mid-scale stellarator is needed to realize the potential predicted by a solid body of theory and simulation along with advances in computational tools for optimization and non-linear turbulence modeling. Notably, it is possible to combine the advantages of the stellarator (steady state, no current drive, no disruptions) with the good confinement regularly achieved in tokamaks. The top priorities for experimental work, and the motivation for a mid-scale stellarator experiment are: turbulence control, non-resonant divertor, MHD stability at large beta, confinement of fast particles, and coil simplification. A new mid-size quasi-symmetric stellarator, built as a user facility, would complement existing research at Wendelstein 7-X and LHD and strongly augment private industry. It would provide a program of innovative research, concept validation, theoretical advancement, and workforce development. Growing support and interest for stellarators by the fusion community and private industry affirms this rationale.
A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.
Fast ion confinement is of major importance for the ignition of a burning fusion plasma. In future deuterium plasma campaigns of the Wendelstein 7-X stellarator, W7-X, the amount of triton burn-up is one possible measure for fast ion confinement. A well-established technique to observe triton burn-up is the 14 MeV neutron rate. In this paper, it is estimated whether an existing scintillating fibre neutron detector is also suited to measure triton burn-up in W7-X with sufficient accuracy. In this work, an estimation is presented, which can be applied to any tokamak or stellarator design and is one-dimensional in the minor radius. The inputs are profiles of density, temperature, and differential volume element as well as the triton slowing-down time. The estimation calculates the thermal deuteron fusion rate and the associated deuteron-triton fusion rate; thus, the triton burn-up generated 14 MeV neutron rate. It neither takes triton diffusion nor explicit losses into account. This thermally generated fusion rate is compared to the neutral beam injection heating induced beam-plasma fusion rate.
The power fall-off length is used as a characteristic dimension to describe the power exhaust in the scrape-off layer (SOL) in magnetic confinement fusion devices. Measurements from the limiter campaign of the stellarator Wendelstein 7-X with inboard limiters are presented with the first-time characterization of the limiter heat loads. Two fall-off regimes are found with a narrow near SOL with power fall-off length in millimeters and a wider far SOL with fall-off lengths of several centimeters. An attempt is made to describe both regimes with a scaling law for plasma with different heating powers and densities. Finally, the results confirm the major geometry effects of the connection length on the heat transport predicted by 3D modeling.
The Wendelstein 7-X (W7-X) optimized stellarator fusion experiment, which went into operation in 2015, has been operating since 2017 with an un-cooled modular graphite divertor. This allowed first divertor physics studies to be performed at pulse energies up to 80 MJ, as opposed to 4 MJ in the first operation phase, where five inboard limiters were installed instead of a divertor. This, and a number of other upgrades to the device capabilities, allowed extension into regimes of higher plasma density, heating power, and performance overall, e.g. setting a new stellarator world record triple product. The paper focuses on the first physics studies of how the island divertor works. The plasma heat loads arrive to a very high degree on the divertor plates, with only minor heat loads seen on other components, in particular baffle structures built in to aid neutral compression. The strike line shapes and locations change significantly from one magnetic configuration to another, in very much the same way that codes had predicted they would. Strike-line widths are as large as 10 cm, and the wetted areas also large, up to about 1.5 m 2 , which bodes well for future operation phases. Peak local heat loads onto the divertor were in general benign and project below the 10 MW m –2 limit of the future water-cooled divertor when operated with 10 MW of heating power, with the exception of low-density attached operation in the high-iota configuration. We report the most notable result was the complete (in all 10 divertor units) heat-flux detachment obtained at high-density operation in hydrogen.
Experiments were performed during the first divertor operational phase (OP1.2a) of the Wendelstein 7-X stellarator to verify predictions of potential overload conditions corresponding to certain high-power long-pulse OP2 scenarios. A potential solution to this overload is the installation of new divertor components called scraper elements, which are designed to intercept heat flux that would otherwise be incident on low-rated divertor edges. Heat flux measurements were obtained in a series of magnetic configurations designed to mimic the magnetic topology evolution caused by net toroidal current and beta, which is not directly accessible in OP1.2a. The experimental flux patterns are qualitatively reproduced in position and magnitude for by field line diffusion simulations using ad hoc cross-field diffusivities near the value used to design the scraper element. However, some important differences are observed, including a shift towards the pumping gap and low-rated components. Potential sources of discrepancy such as toroidal current evolution and error fields are discussed. In conclusion, a shift in the experimental heat flux pattern due to increasing toroidal current is observed in a 12 s discharge.
Global confinement properties of the limiter plasmas of the first operational campaign of W7-X are investigated with special focus on the energy confinement and possible operational limits. The energy confinement time was found to be close to expectations from the empirical ISS04 scaling for stellarators. Absolute values up to 160 ms were achieved. This can be considered as a great success for the initial operation of the device. However, a clear degradation of the performance was observed when radiative losses became significant, which was typically the case at low heating power. While a significant improvement of the plasma purity is expected during divertor operation, the presented results underline the importance of the impurity dynamics for the development of high-performance steady-state scenarios in W7-X. Furthermore, comparisons of the global performance properties with neoclassical transport modeling are presented. Furthermore, these studies are not yet fully conclusive, which could indicate that anomalous transport may have played an essential role in the low-density OP1.1 plasmas.
Two graphite divertor elements called scrapers have been installed on the Wendelstein 7-X stellarator in the throat of the magnetic island divertor. To diagnose one, we have designed, built, calibrated, and installed a new infrared/visible imaging endoscope system to enable detailed observations of the plasma interactions and heat loads at one of the scrapers and the nearby divertor surfaces. The new system uses a shuttered pinhole-protected pair of 90° off-axis 228 mm focal length aluminum parabolic mirrors, and two flat turning metal mirrors, to send light to a sapphire vacuum window 1.6 meters away, beyond which we have co-located telephoto lens-based infrared and visible cameras. The back-to-back off-axis parabolas serve to cancel out most aberrations, enabling the use of off-the-shelf commercial optics outside of the vessel. For the infrared, we use a 3-5 μm 1-megapixel FLIR SC8303HD camera and for the visible, a 5-megapixel CMOS PCO 5.5 edge camera. A short 1-m quartz pickoff fiber is used to send 200-1100 nm light to a compact spectrometer, also located in the same iron shield box as the cameras. The camera field of view covers the 700 mm length of the scraper, and includes locations monitored by thermocouples and Langmuir probes embedded in some of the scraper tiles. Predicted and actual optical test performances of the overall system are then compared.
The edge magnetic structure in the Helically Symmetric eXperiment (HSX) and Wendelstein 7X (W7-X) stellarators has been shown to have a significant impact on the particle fueling and exhaust of the plasma main species (hydrogen) as well as impurity helium. For HSX, the plasma sourcing to exhaust ratio, quantified by the effective and global particle confinement times τ p * and τ p , H , respectively, increases when a magnetic island chain is located in the plasma edge. The fueling efficiency is reduced by 25% when the plasma boundary is deformed by the magnetic islands. The X-point geometry also yields higher plasma temperatures in front of the main recycling region. When the island is moved radially inward, both τ p * and τ p decrease by 10 % – 25 % depending on plasma density. The τ p , H results rely heavily on EMC3-EIRENE modeling which confirms reduced fueling efficiency due to more rapid ionization in the outward shifted island position. These findings suggest that for a helically optimized system like HSX, the plasma fueling from the recycling source, as well as from active gas injection, can be controlled by the magnetic island chain in the plasma edge—which is a basic requirement for a divertor system. This process is also effective for the control of effective helium exhaust times, as τ p , H e * measured by perturbative gas puff experiments is reduced by up to 40% when the islands are shifted inwards. For Wendelstein 7-X, a similar reduction of τ p , H e * was inferred when magnetic islands were moved from the far plasma edge into the confined plasma region. Finally, however, the effective confinement features of H as the main plasma species were not affected due to the non-optimal position of the magnetic islands with respect to the highly localized ionization domain during the limiter startup campaign.
In this work, Wendelstein 7-X (W7-X) is the world’s largest superconducting nuclear fusion experiment of the optimized stellarator type. In the first Operation Phase (OP1.1) helium and hydrogen plasmas were studied in limiter configuration. The heating energy was limited to 4 MJ and the main purpose of that campaign was the integral commissioning of the machine and diagnostics, which was achieved very successfully. Already from the beginning a comprehensive set of diagnostics was available to study the plasma. On the path towards high-power, high-performance plasmas, W7-X will be stepwise upgraded from an inertially cooled (OP1.2, limited to 80 MJ) to an actively cooled island divertor (OP2, 10 MW steady-state plasma operation). The machine is prepared for OP1.2 with 10 inertially cooled divertor units, and the experimental campaign has started recently.The paper describes a subset of diagnostics which will be available for OP1.2 to study the plasma edge, divertor and scrape-off layer physics including those already available for OP1.1, plus modifications, upgrades and new systems. In conclusion, the focus of this summary will be on technical and engineering aspects, like feasibility and assembly but also on reliability, thermal loads and shielding against magnetic fields.
In the first campaign Wendelstein 7-X was operated with five poloidal graphite limiters installed stellarator symmetrically. In an ideal situation the power losses would be equally distributed between the limiters. The limiter shape was designed to smoothly distribute the heat flux over two strike lines. Vertically the strike lines are not uniform because of different connection lengths. In this paper it is demonstrated both numerically and experimentally that the heat flux distribution can be significantly changed by non-resonant $n=1$ perturbation field of the order of $10^{-4}$ . Numerical studies are performed with field line tracing. In experiments perturbation fields are excited with five error field trim coils. The limiters are diagnosed with infrared cameras, neutral gas pressure gauges, thermocouples and spectroscopic diagnostics. Experimental results are qualitatively consistent with the simulations. With a suitable choice of the phase and amplitude of the perturbation a more symmetric plasma-limiter interaction can be potentially achieved. Finally, these results are also of interest for the later W7-X divertor operation.
Observations on confinement in the first experimental campaign on the optimized Stellarator Wendelstein 7-X are summarized. In this phase W7-X was equipped with five inboard limiters only and thus the discharge length restricted to avoid local overheating. Stationary plasmas are limited to low densities <2–3 centerdot 10 19 m -3 . With the available 4.3 MW ECR Heating core T e ~ 8 keV, T i ~ 1–2 keV are achieved routinely resulting in energy confinement time τ E between 80 ms to 150 ms. For these conditions the plasmas show characteristics of core electron root confinement with peaked T e -profiles and positive E r up to about half of the minor radius. Lastly, profiles and plasma currents respond to on- and off-axis heating and co- and counter ECCD respectively.