Kinetics and Mechanism of the Singlet Oxygen Atom Reaction with Dimethyl Ether

Here, we combine in situ laser spectroscopy, quantum chemistry, and kinetic calculations to study the reaction of a singlet oxygen atom with dimethyl ether. Infrared laser absorption spectroscopy and Faraday rotation spectroscopy are used for the detection and quantification of the reaction products OH, H 2 O, HO 2 , and CH 2 O on submillisecond time scales. Fitting temporal profiles of products with simulations using an in-house reaction mechanism allows product branching to be quantified at 30, 60, and 150 Torr. The experimentally determined product branching agrees well with master equation calculations based on electronic structure data and transition state theory. The calculations demonstrate that the dimethyl peroxide (CH 3 OOCH 3 ) generated via O-insertion into the C–O bond undergoes subsequent dissociation to CH 3 O + CH 3 O through energetically favored reactions without an intrinsic barrier. This O-insertion mechanism can be important for understanding the fate of biofuels leaking into the atmosphere and for plasma-based biofuel processing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stationary and drone-assisted methane plume localization with dispersion spectroscopy

This work presents stationary and mobile retroreflector-based remote sensing techniques for methane leak localization and quantification using chirped laser dispersion spectroscopy equipped with a custom laser transceiver capable of continuous tracking of a flying drone and coupled with inverse atmospheric gas dispersion modeling. The techniques demonstrate the ability to localize leaks as low as 0.13 g CH 4 ·s -1 , which are up to 25 times smaller than those typically observed at natural gas facilities, as well as actively track a moving retroreflector mounted on a lightweight (~250 g) drone to enable spatial plume reconstruction. This system exhibited a 2.3 ppm-m sensitivity over pathlengths of 40–150 m. Source localization to within ±7 m is demonstrated using a modified horizontal radial plume mapping technique with a stationary retroreflector grid. Meanwhile, the mobile system utilizing a drone-mounted retroreflector is able to localize a controlled release within ±1 m of its source location and estimate leak rates using inversion techniques assuming type B Gaussian plume stability class within ±30% error with respect to the actual low flow rate releases.

47 OTHER INSTRUMENTATION↗

Fourier domain dynamic correction method for complex optical fringes in laser spectrometers

A method is provided for Fourier domain dynamic correction of optical fringes in a laser spectrometer. The method includes Fourier transforming a background spectrum contaminated with the optical fringes to obtain baseline fringes in a frequency domain. The method includes partitioning the baseline fringes in the frequency domain to obtain partitioned baseline fringes. The method includes reconstructing the partitioned baseline fringes as separate spectra. The method includes constructing a fitting model to approximate the background spectrum by assigning a first and a second free parameter to each of partitioned baseline fringe components to respectively allow for drift and amplitude adjustments during a fitting of the fitting model. The method includes applying the fitting model to a newly acquired spectrum to provide an interpretation of the newly acquired spectrum having a reduced influence of spectral contamination on concentration retrieval.

Teng, Cheyenne↗

Feed-forward spectral calibration methodology for line-scanned tunable laser absorption spectroscopy

A generalized feed-forward method for accurate tunable laser absorption spectroscopy includes generating a laser beam. The generated laser beam is directed down a reference path and a test/sample path. One or more parameters are extracted from the reference path. The one or more parameters, extracted from the reference path, are used as feed-forward, to adjust spectral analysis of the test/sample path to detect a composition and/or concentration of an analyte gas within the test/sample path. The extraction of the one or more parameters from the reference path and the spectral analysis of the test/sample path are performed substantially concurrently.

Green, William↗

On-chip spectroscopic sensors with optical fringe suppression

An on-chip spectroscopic sensor includes a tunable diode laser. A laser driver for drives the tunable diode laser. An analyte test cavity receives a chemical sample and exposes the received chemical sample to light from the tunable diode laser. An optical detector detects light emerging from the analyte test cavity as a result of the laser exposure. A spectral analyzer determines a spectrum of the emerging light, matches and removes one or more known optical fringe patterns from the determined spectrum, and determines a composition or concentration of the chemical sample from the optical fringe pattern-removed spectrum.

Green, William↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗

Kinetic studies of excited singlet oxygen atom O( 1 D) reactions with ethanol

In this work, themultichannel reaction of excited singlet oxygen atom with ethanol, O( 1 D) + C 2 H 5 OH (1), was studied in a photolysis flow reactor coupled with mid-infrared Faraday rotation spectroscopy (FRS) and UV-IR direct absorption spectroscopy (DAS) at 297 K with reactor pressures of 60, 120, and 150 Torr (bath He). The excited singlet oxygen atom was generated through the photolysis of O 3 at 266 nm. The photon flux and O( 1 D) concentrations were determined by in situ actinometry based on O 3 depletion. Temporal profiles of OH and H 2 O were monitored via DAS signals at ca. 3568.62 and 3568.29 cm –1 , while temporal profiles of HO 2 were measured via FRS signals at ca. 1396.90 cm –1 . The branching ratios of the target reaction (1) were determined by fitting temporal profiles to simulations from an in-house reaction mechanism. Two major reaction channels were identified as CH 3 CHOH + OH and CH 3 O + CH 2 OH, and their branching ratios were determined as 0.46 ± 0.12 and 0.42 ± 0.11, respectively. A specific HO 2 + RO 2 reaction between HO 2 and O 2 CH 2 CH 2 OH (β-RO 2 ) at the low-temperature range is estimated in this work as HO 2 + O 2 CH 2 CH 2 OH → products with a rate constant of 7 × 10 –12 cm 3 molecule –1 s –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chirped laser dispersion spectroscopy for spectroscopic chemical sensing with simultaneous range detection

Spectroscopic chemical detection requires knowledge or determination of an optical path for accurate quantification of path-integrated concentration of species. Continuous- wave-laser-based spectroscopic systems operating in an open integrated-path remote sensing configuration are usually not equipped for optical path determination. Here we demonstrate a measurement technique capable of simultaneous spectroscopic chemical quantification and range finding. Here, the range-finding functionality is implemented with chirped laser dispersion spectroscopy. The methodology is potentially useful for remote chemical sensing in a hard-target LIDAR configuration and for automatic calibration of gas cells with unknown or varying lengths.

03 NATURAL GAS↗

Kinetic study of reaction C 2 H 5 + HO 2 in a photolysis reactor with time-resolved Faraday rotation spectroscopy

The rate constant and branching ratios of ethyl reaction with hydroperoxyl radical, C 2 H 5 + HO 2 (1), a key radical-radical reaction for intermediate temperature combustion chemistry, were measured in situ for the first time in a photolysis Herriott cell by using mid-IR Faraday rotation spectroscopy (FRS) and UV-IR direct absorption spectroscopy (DAS). The microsecond time-resolved diagnostic technique in this work enabled the direct rate measurements of the target reaction at 40 and 80 mbar and reduced the experimental uncertainty considerably. C 2 H 5 and HO 2 radicals were generated by the photolysis of (COCl) 2 /C 2 H 5 I/CH 3 OH/O 2 /He mixture at 266 nm. By direct measurements of the transient profiles of C 2 H 5 , HO 2 and OH concentrations, the overall rate constant for this reaction at 297 K was determined as k 1 (40 mbar) = (3.8 ± 0.8) × 10 –11 cm 3 molecule –1 s –1 and k 1 (80 mbar) = (4.1 ± 1.0) × 10 –11 cm 3 molecule –1 s –1 . As a result, the direct observation of hydroxyl radical (OH) indicated that OH formation channel was the major channel with a branching ratio of 0.8 ± 0.1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Terahertz Spectroscopy of Gas Mixtures with Dual Quantum Cascade Laser Frequency Combs

Terahertz laser frequency combs based on quantum cascade lasers provide coherent, broadband, electrically pumped, THz radiation sources for use in future spectroscopic applications. In this work, we explore the feasibility of such lasers in a dual-comb spectroscopy configuration for the detection of multiple molecular samples in the gas phase. The lasers span approximately 180 GHz of optical bandwidth, centered at 3.4 THz, with submilliwatt total optical power. One of the main advantages of dual-comb spectroscopy is its high speed, which opens up the possibility for direct observations of chemical reaction dynamics in the terahertz spectral region. As a proof-of-concept, we recorded continuously evolving spectra from gas mixtures with 1 ms temporal resolution.

42 ENGINEERING↗

On-chip spectroscopic sensors with optical fringe suppression

An on-chip spectroscopic sensor includes a tunable diode laser. A laser driver for drives the tunable diode laser. An analyte test cavity receives a chemical sample and exposes the received chemical sample to light from the tunable diode laser. An optical detector detects light emerging from the analyte test cavity as a result of the laser exposure. A spectral analyzer determines a spectrum of the emerging light, matches and removes one or more known optical fringe patterns from the determined spectrum, and determines a composition or concentration of the chemical sample from the optical fringe pattern-removed spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passively mode-locked interband cascade lasers

Optical frequency combs have revolutionized the field of high resolution real-time molecular spectroscopy. Here, we demonstrate an electrically-driven optical frequency comb whose sub-picosecond pulses span more than 1 THz of spectral bandwidth centered near 3.3 mm. This is achieved by passively mode locking an interband cascade laser in a multi-contact architecture with gain and saturable absorber sections monolithically integrated on the same chip.

Wysocki, Gerard↗

Mode Tracker for Mode-Hop-Free Operation of a Laser

A mode-tracking system that includes a mode-controlling subsystem has been incorporated into an external-cavity (EC) quantum cascade laser that operates in a mid-infrared wavelength range. The mode-tracking system makes it possible to perform mode-hop-free wavelength scans, as needed for high-resolution spectroscopy and detection of trace gases. The laser includes a gain chip, a beam-collimating lens, and a diffraction grating. The grating is mounted on a platform, the position of which can be varied to effect independent control of the EC length and the grating angle. The position actuators include a piezoelectric stage for translation control and a motorized stage for coarse rotation control equipped with a piezoelectric actuator for fine rotation control. Together, these actuators enable control of the EC length over a range of about 90 m with a resolution of 0.9 nm, and control of the grating angle over a coarse-tuning range of +/-6.3deg and a fine-tuning range of +/-520 microrad with a resolution of 10 nrad. A mirror mounted on the platform with the grating assures always the same direction of the output laser beam.

Wysocki, Gerard↗

Piezo activated mode tracking system for widely tunable mode-hop-free external cavity mid-IR semiconductor lasers

A widely tunable, mode-hop-free semiconductor laser operating in the mid-IR comprises a QCL laser chip having an effective QCL cavity length, a diffraction grating defining a grating angle and an external cavity length with respect to said chip, and means for controlling the QCL cavity length, the external cavity length, and the grating angle. The laser of claim 1 wherein said chip may be tuned over a range of frequencies even in the absence of an anti-reflective coating. The diffraction grating is controllably pivotable and translatable relative to said chip and the effective QCL cavity length can be adjusted by varying the injection current to the chip. The laser can be used for high resolution spectroscopic applications and multi species trace-gas detection. Mode-hopping is avoided by controlling the effective QCL cavity length, the external cavity length, and the grating angle so as to replicate a virtual pivot point.

Wysocki, Gerard↗

Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser

The external-cavity quantum cascade laser (EC-QCL) system is based on an optical configuration of the Littrow type. It is a room-temperature, continuous wave, widely tunable, mode-hop-free, mid-infrared, EC-QCL spectroscopic source. It has a single-mode tuning range of 155 cm(exp -1) (approximately equal to 8% of the center wavelength) with a maximum power of 11.1 mW and 182 cm(exp -1) (approximately equal to 15% of the center wavelength), and a maximum power of 50 mW as demonstrated for 5.3 micron and 8.4 micron EC-QCLs, respectively. This technology is particularly suitable for high-resolution spectroscopic applications, multi-species tracegas detection, and spectroscopic measurements of broadband absorbers. Wavelength tuning of EC-QCL spectroscopic source can be implemented by varying three independent parameters of the laser: (1) the optical length of the gain medium (which, in this case, is equivalent to QCL injection current modulation), (2) the length of the EC (which can be independently varied in the Rice EC-QCL setup), and (3) the angle of beam incidence at the diffraction grating (frequency tuning related directly to angular dispersion of the grating). All three mechanisms of frequency tuning have been demonstrated and are required to obtain a true mode-hop-free laser frequency tuning. The precise frequency tuning characteristics of the EC-QCL output have been characterized using a variety of diagnostic tools available at Rice University (e.g., a monochromator, FTIR spectrometer, and a Fabry-Perot spectrometer). Spectroscopic results were compared with available databases (such as HITRAN, PNNL, EPA, and NIST). These enable precision verification of complete spectral parameters of the EC-QCL, such as wavelength, tuning range, tuning characteristics, and line width. The output power of the EC-QCL is determined by the performance of the QC laser chip, its operating conditions, and parameters of the QC laser cavity such as mirror reflectivity or intracavity losses. In order to maximize the output power, an analysis and optimization of the EC laser parameters has been performed. The parameters of the beam emitted from the gain medium, such as divergence angle, beam profile, and astigmatism, have been investigated. The gain medium has been fully characterized before and after each stage of modification. The main modification steps are coating one facet of the gain chip with a high reflectivity mirror and the other facet with an anti-reflection layer. Then the chip is mounted in the EC-QCL. The optomechanical design has been reviewed and improved to provide for precise collimation of the strongly divergent beam of the QCL and the tuning diffraction grating.

Wysocki, Gerard↗