Search NASA⌕ Search

Engineering topics

Xiaojun, Zhong

Publications and source records attributed to Xiaojun, Zhong.

One-way quantum computation with circuit quantum electrodynamics

In this Brief Report, we propose a potential scheme to implement one-way quantum computation with circuit quantum electrodynamics (QED). Large cluster states of charge qubits can be generated in just one step with a superconducting transmission line resonator (TLR) playing the role of a dispersive coupler. A single-qubit measurement in the arbitrary basis can be implemented using a single electron transistor with the help of one-qubit gates. By examining the main decoherence sources, we show that circuit QED is a promising architecture for one-way quantum computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of {sup 18}F-Fluorothymidine and {sup 18}F-Fluorodeoxyglucose PET/CT in Delineating Gross Tumor Volume by Optimal Threshold in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

Purpose: To determine the optimal method of using {sup 18}F-fluorothymidine (FLT) positron emission tomography (PET)/computed tomography (CT) simulation to delineate the gross tumor volume (GTV) in esophageal squamous cell carcinoma verified by pathologic examination and compare the results with those using {sup 18}F-fluorodeoxyglucose (FDG) PET/CT. Methods and Materials: A total of 22 patients were enrolled and underwent both FLT and FDG PET/CT. The GTVs with biologic information were delineated using seven different methods in FLT PET/CT and three different methods in FDG PET/CT. The results were compared with the pathologic gross tumor length, and the optimal threshold was obtained. Next, we compared the simulation plans using the optimal threshold of FLT and FDG PET/CT. The radiation dose was prescribed as 60 Gy in 30 fractions with a precise radiotherapy technique. Results: The mean +- standard deviation pathologic gross tumor length was 4.94 +- 2.21 cm. On FLT PET/CT, the length of the standardized uptake value 1.4 was 4.91 +- 2.43 cm. On FDG PET/CT, the length of the standardized uptake value 2.5 was 5.10 +- 2.18 cm, both of which seemed more approximate to the pathologic gross tumor length. The differences in the bilateral lung volume receiving >=20 Gy, heart volume receiving >=40 Gy, and the maximal dose received by spinal cord between FLT and FDG were not significant. However, the values for mean lung dose, bilateral lung volume receiving >=5, >=10, >=30, >=40, and >=50 Gy, mean heart dose, and heart volume receiving >=30 Gy using FLT PET/CT-based planning were significant lower than those using FDG PET/CT. Conclusion: A standardized uptake value cutoff of 1.4 on FLT PET/CT and one of 2.5 on FDG PET/CT provided the closest estimation of GTV length. Finally, FLT PET/CT-based treatment planning provided potential benefits to the lungs and heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography to Estimate the Length of Gross Tumor in Patients With Squamous Cell Carcinoma of the Esophagus

Purpose: To determine the optimal method of using {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) to estimate gross tumor length in esophageal carcinoma. Methods and Materials: Thirty-six patients with esophageal squamous cell carcinoma treated with radical surgery were enrolled. Gross tumor volumes (GTVs) were delineated using three different methods: visual interpretation, standardized uptake value (SUV) 2.5, and 40% of maximum standard uptake value (SUV{sub max}) on FDG-PET imaging. The length of tumors on PET scan were measured and recorded as Length{sub vis}, Length{sub 2.5}, and Length{sub 40}, respectively, and compared with the length of gross tumor in the resected specimen (Length{sub gross}). All PET data were reviewed again postoperatively, and the GTV was delineated using various percentages of SUV{sub max}. The optimal-threshold SUV was generated when the length of PET matched the Length{sub gross}. Results: The mean ({+-}SD) Length{sub gross} was 5.48 {+-} 1.98 cm. The mean Length{sub vis}, Length{sub 2.5}, and Length{sub 40} were 5.18 {+-} 1.93 cm, 5.49 {+-} 1.79 cm, and 4.34 {+-} 1.54 cm, respectively. The mean Length{sub vis} (p = 0.123) and Length{sub 2.5} (p = 0.957) were not significantly different from Length{sub gross}, and Length{sub 2.5} seems more approximate to Length{sub gross.} The mean Length{sub 40} was significantly shorter than Length{sub gross} (p < 0.001). The mean optimal threshold was 23.81% {+-} 11.29% for all tumors, and it was 19.78% {+-} 8.59%, 30.92% {+-} 12.28% for tumors {>=}5 cm, and <5 cm, respectively (p = 0.009). The correlation coefficients of the optimal threshold were -0.802 and -0.561 with SUV{sub max} and Length{sub gross}, respectively. Conclusions: The optimal PET method to estimate the length of gross tumor varies with tumor length and SUV{sub max}; an SUV cutoff of 2.5 provided the closest estimation in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗