Search NASA⌕ Search

Engineering topics

Xiaoli, Zhu

Publications and source records attributed to Xiaoli, Zhu.

Note: Continuing improvements on the novel flat-response x-ray detector

This note describes multi-updates of the novel flat-response x-ray detector in fabrication technology, experimental application, and data uncertainty evaluation. Unlike the previous design, the compound filter is combined into one piece through an improved fabrication process that greatly enhanced its self-supporting capability. A method of pinhole-array imaging is introduced into the experimental application process to stop any debris from the hohlraum and to uniformly reduce the radiation flux. The experimental results show that this method works well. Furthermore, a method of uncertainty evaluation of the radiation flux measurement by the novel flat-response x-ray detector has been developed. The influence of the radiation spectrum to the flux measurement is analyzed. The evaluation shows that the relative uncertainty of the radiation flux is about 10% in higher radiation temperature condition (Tr > 150 eV) and 16% in lower radiation temperature condition (Tr < 100 eV).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utility of the Amplatzer Vascular Plug in Splenic Artery Embolization: A Comparison Study with Conventional Coil Technique

Purpose: To retrospectively evaluate the role of the Amplatzer Vascular Plug (AVP) in proximal splenic artery embolization (SAE) compared with coils. Materials and Methods: Forty patients had proximal SAE performed with AVP(s) or coils as the primary embolic agent for splenic artery steal syndrome (n = 23), trauma (n = 5), portal hypertension (n = 5), bleeding due to pancreatic pathology (n = 4), and pre-splenectomy (n = 3). Comparisons were made of occlusion and procedure time, cost, and radiation dose. Results: Eighteen proximal SAE procedures were successfully performed with AVP. Twenty-two procedures were performed with coils, including one failed AVP attempt, which was completed with coils. Precise deployment without migration was achieved in all 18 AVP cases. Seven of 22 (31.8%) coil procedures had distal migration without consequence. There was no statistically significant difference in mean occlusion time (24.4 min for AVP vs. 31.5 min for coils, P = 0.13), procedure time (43.7 min for AVP vs. 53.8 min for coils, P = 0.16), or cost ($1474.13 for AVP vs. $1722.51 for coils, P = 0.69). There was significant difference in radiation dose (842 mGy for AVP vs. 1,309 mGy for coils, P = 0.04). Fourteen of the 18 (78%) AVP devices required additional embolic material. Conclusions: AVP with additional embolic agents is a useful alternative for proximal SAE because of precise deployment, resistance to migration, and radiation reduction. AVP use may be limited by vessel tortuosity. The occlusion time, procedure time, and cost were reduced but this was not statistically significant due to the need for additional embolic material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗