ComStock Standard Dataset Release: Commercial 2024 Release 2
In this webinar, we present the ComStock Standard Dataset Release, 2024 Release 2. The agenda includes an overview of ComStock, new measure scenarios, and how to access the public dataset.
Engineering topics
Publications and source records attributed to Xiong, Jie.
In this webinar, we present the ComStock Standard Dataset Release, 2024 Release 2. The agenda includes an overview of ComStock, new measure scenarios, and how to access the public dataset.
This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.
This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.
This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".
This presentation, part of an NREL-hosted webinar in April 25th 2024, discusses ComStock end-use savings shapes and public datasets.
ComStock™ is an NREL model of the U.S. commercial building stock. The model takes some building characteristics from the U.S. Department of Energy's (DOE's) Commercial Prototype Building Models and Commercial Reference Building. However, unlike many other building stock models, ComStock also combines these with a variety of additional public- and private-sector data sets. Collectively, this information provides high-fidelity building stock representation with a realistic diversity of building characteristics. This repository contains the source code used to build and execute ComStock models, including upgrade scenarios. In addition, the sampling of buildings characteristics used for the initial ComStock (V1.0) release is provided. The ComStock model is under active calibration and development, which is publicly visible on this repository. Execution of the ComStock workflow is managed through the buildstockbatch repository, a shared asset of ResStock™ and ComStock™ , specifically developed to scale to execution of tens of millions of simulations through multiple infrastructure providers. The dataset output from the initial ComStock (V1.0) release can be found at the accompanying ComStock data viewer website and additional information about ComStock found on the NREL Buildings Website. For more details about ongoing model development please consult the End Use Load Profiles website. ComStock is a direct result of the NREL residential stock modeling tool ResStock™ (recipient of a R&D100 award) and was inspired by the high-fidelity solar & storage adoption model dGen™. Additionally, this tool would not be possible without the decades of work undertaken by the OpenStudio® and EnergyPlus® visionaries and contributors, significant funding, feedback and support from the Los Angeles Department of Water and Power, and the Department of Energy's Building Technology Office ongoing support of and investment in building energy modeling software. is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.
A perennial challenge in buildings research is the lack of high-quality datasets that can be relied upon for a wide array of tasks, including model calibration and improving energy efficiency and load flexibility. Instrumenting a building for data collection is resource intensive, so it is important to be methodical in the approach and ensure that resulting data are flexible and useful for a broad range of analyses. This study aims to fill the gaps in characterizing potential use cases for buildings datasets and mapping them to dataset needs using a well-defined data infrastructure. Here, we have developed a systematic mapping strategy between buildings dataset needs and use cases to help streamline the processes of efficiently targeting datasets, designing building sensing systems, and determining buildings research use cases. We selected 14 prospective use cases and 11 refined buildings data categories for developing the preliminary dataset-needs-to-use-cases mapping matrix (‘DN-UC mapping matrix’) with generic ‘Tags’—a detailed sub-level of data categories extracted by justifying the needs of an aspect of the datasets to use cases. We present two example applications of the developed mapping matrix to demonstrate use of the mapping matrix and its effectiveness.
Charging energy-dense lithium-ion batteries (LIBs) with thick graphite electrodes at high current densities are typically accompanied by poor performance and safety issues. The root cause is the onset of Li plating at the surface of graphite when lithiated to a high capacity within a short time period. Here, we investigated the behavior of graphite electrodes with various particle sizes under fast charge operations. Results from the electrochemical characterization on graphite electrodes exhibit the superiority of smaller particles over bigger particles in terms of suppressing the onset of Li plating and growth of plated Li particles. Observations from scanning electron microscopy also corroborate the presence of plated Li in electrodes with big graphite particles and its absence in graphite electrodes with small particles, when the cells were lithiated to 90% of the state of charge (SOC). Further, the improved performance of cells with the small particles might be associated with the low Li-ion concentration at the surface of graphite and thus reduced overpotential in graphite electrodes. The simulated results revealed that, compared to bigger particles, smaller particles have lower surface intercalation at any given cell SOC, which may significantly reduce the overpotential in the graphite electrodes and mitigate the onset of Li plating. This agrees well with experimental observations.
The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.
The tendency of Li plating at the surface of thick graphite electrodes greatly limits their application in electrical vehicle (EV) batteries for fast charging applications. To address this concern, we proposed an innovative gradient porosity architecture to facilitate mass transport and suppress Li plating in the thick anodes for fast charging applications. This concept was approved through a thick 3-layered graphite electrode with the highest porosity in the top layer and the lowest porosity in the bottom layer, in contact with the current collector. Here, the gradient porosity structure in the 3-layered graphite electrodes was confirmed by electron microscopy and mercury porosimetry measurements. Used as the anodes of lithium-ion batteries, 3-layered graphite electrodes demonstrated unprecedentedly rate capability and durability superior to 1-layered electrodes. The post-mortem analysis on the cycled cells shows that 3-layered electrodes can significantly suppress Li plating at a high rate up to 4C, which might be responsible for the improved performance of the derived cells. The excellent electrochemical behaviors of 3-layered graphite electrodes are associated with the favored mass transport originating from the unique gradient porosity structure. This is consistent with theoretical studies showing that gradient porosity lowers the Li-ion concentration gradient in the electrolyte in the region close to the separator and slows down the process of reaching the Li plating threshold.
Five double perovskites, each containing a transition-metal ion with a 5d 1 configuration, have been studied to better understand the surprising diversity of magnetic ground states seen in these isoelectronic compounds. Ba 2 ZnReO 6 adopts the cubic double perovskite structure and magnetically orders below 16 K, with a canted ferromagnetic structure and a saturated magnetization of ~0.24 μ B /Re. X-ray magnetic circular dichroism indicates a substantial orbital moment of approximately 0.4 μ B /Re that opposes the spin moment. The structures of Ba 2 NaOsO 6 (canted ferromagnet, T C = 7 K) and Ba 2 LiOsO 6 (antiferromagnet, T N = 8 K) are reinvestigated using time-of-flight neutron powder diffraction and found to crystallize with the cubic double perovskite structure. No evidence for a structural distortion can be found in either compound down to 10 K. Ba 2 CdReO 6 is also cubic at room temperature but undergoes a structural transition upon cooling below ~180 K to a tetragonal structure with I4/m symmetry that involves compression of the Re–O bonds that are parallel to the c-axis. Sr 2 LiOsO 6 shows a similar tetragonal distortion at room temperature and maintains that structure down to 10 K. Surprisingly, the Os-centered octahedron in Sr 2 LiOsO 6 is distorted in the opposite direction, exhibiting an elongation of the Os–O bonds along the c-axis. Differences in the distortions of the octahedra lead to different magnetic ground states, antiferromagnetic (T N = 4 K) for Ba 2 CdReO 6 and spin glass (T g = 30 K) for Sr 2 LiOsO 6 . Theoretical modeling shows that the varied magnetic behaviors of double perovskites containing 5d 1 ions are closely tied to crystallographic distortions. Furthermore, these distortions remove the degeneracy of the 5d t 2g orbitals, leading to changes in orbital occupation that ultimately determine which of the several competing magnetic ground states is favored.
An oxide layer on the surface of silicon particles is inevitable and is necessary for their application as anode materials for lithium ion batteries with high capacity and durability. However, a thick surficial oxide layer could significantly reduce the capacity of a Si anode. Here, Si nanoparticles with a thick surficial oxide layer of ~20 nm (Si@SiO x ) were fabricated through thermal oxidation and investigated electrochemically. The results revealed that very low current density is needed to activate Si@SiO x anodes during the first formation cycle. Once activated, the Si@SiO x anode can deliver reversible capacity as high as ~1000 mAh/g with low current density. Then, the Si@SiO x can be cycled at higher current densities of >700 mAh/g. Electrochemical impedance spectroscopy (EIS) shows that the lower current density results in lower charge-transfer resistance of the Si@SiO x anode, suggesting a higher degree of lithiation of the surficial oxide layer during low-current activation. EIS analysis also reveals that the lithiation of the surficial oxide is irreversible. We believe that the surface silicon oxide layer is lithiated and forms lithium silicate during the initial activation process. Lithium silicate has high conductivity and allows the lithiation/delithiation of Si core under the oxide layer during following charge and discharge.
With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.
The effects of indoor environmental conditions on human health, satisfaction, and performance have been the focal point of research for decades. This paper reviews and summarizes the impact of lighting environment on task performance, specifically for the built environment audience. Existing studies included a variety of performance tests on cognitive performance and perception, visual acuity and reaction, memory, reasoning, and labor productivity. Illuminance, luminance ratio and correlated color temperature were found to affect performance in different ways, reflecting the impact of experimental techniques, conditions, performance evaluation methods used and data analysis methods. These were reviewed and categorized, with discussion on limitations related to sample size, modeling approach, carryover effects and other factors affecting individual differences in performance, with recommendations for future improvement. Although no universal conclusions can be made, in general, task performance seems to improve with higher illuminances, contrast ratios in the range of 7–11:1 (while always making sure that glare will not occur in the space) and higher correlated color temperature, while spectral tuning in the red or blue wavelengths has also shown positive effects. To obtain more generic evidence, future studies should be more consistent in terms of experimental procedures and overall light conditions, and also consider the effects of vertical illuminance, daylight provision/control, and outside views on task performance. Finally, studying performance with multi-factorial designs in a human-centered optimized manner (such as deploying variable lighting scenarios optimized for various tasks) can lead to deeper understanding of lighting effects on task performance, and ultimately to improved lighting design and operation in buildings overall.
Highlights: • 1D TiO{sub 2} nanofibrous film was prepared by electrospinning technique as mesoporous of PSCs. • PSCs were fabricated under ambient conditions even with a high humidity condition more than 40%. • The 1D TiO{sub 2} nanofiber-based PSCs achieved a power conversion efficiency (PCE) about 11.6% compared with 7.5% whereas the 0D TiO{sub 2} nanoparticle-based PSCs only has 7.5%. - Abstract: One-dimensional (1D) TiO{sub 2} nanofibrous film with good morphology and electrical characteristics was prepared by electrospinning technique. And then perovskite solar cells (PSCs) were fabricated based on 2-μm-thick mesoporous TiO{sub 2} nanofibrous film under ambient conditions even with a high humidity condition more than 40%. The devices show high power conversion efficiency (PCE) due to high porosity that is beneficial to the loading of CH{sub 3}NH{sub 3}PbI{sub 3} perovskite layer. This high-porosity 1D TiO{sub 2} nanofibrous film also acts as a protection layer which can enhance the moisture stability of CH{sub 3}NH{sub 3}PbI{sub 3}. As a result, conversion efficiency of 11.6% and short-circuit current density (J{sub sc}) of 17.3 mA were achieved under 100 mW cm{sup −2} AM 1.5 G solar illumination. These two values are both higher than those of zero-dimensional (0D) TiO{sub 2} nanoparticulate film-based devices.
Abstract not provided